Verified by manufacturer over a year ago
Aluminium Foil Reinforced Tape is used for sealing TBA Firefly™ Non-Combustible Sarking joints.
Aluminium Foil Reinforced Tape is used for sealing TBA Firefly™ Non-Combustible Sarking joints.
Comprised of fire-retardant acrylic adhesive and two non-combustible layers. A Fortaglas reinforcement layer and an aluminium foil layer.
Finish | Aluminium reinforced tape. |
Material | Acrylic adhesive. Fortaglas reinforcement layer. Aluminium foil layer. |
Length | 50000 mm |
Width | 75 mm |
Uniclass | |
NATSPEC National Classification System | 0182 Fire-Stopping |
SpecPack | 07810 Fireproofing |
SpeedSpec | 07810 Fireproofing |
Material | Fortaglas reinforcement layer.Aluminium foil layer. |
Bond | Acrylic adhesive. |
Size (width) | 75 mm. |
Roll length | 50 meters roll. |
Certification | Tested and approved to NCC 2019 Volume 1 (Amendment 1). |
Fire performance | To AS/NZS 1530.3-1999. |
SurfaceSpreadOfFlame | Class 0. |
Fire/ smoke control performance | Class 2. |
Fire testing - non combustibility | To AS 1530.1-1994. Guidance for specification option: Both layers are NOT deemed COMBUSTIBLE. |