NBS Source
I'm a manufacturer

Deckshield ED Rapide

Verified by manufacturer over a year ago

Flowcrete Third party certifications:
  • AWTA Test results

    Certificate type

Deckshield ED Rapide is a crack bridging MMA resin-based car park deck waterproof coating for exposed decks.

Jump to:
1800 318 038 Website

Application

Used to cosmetically enhance and waterproof external and multi-storey carparks.

Description

A crack bridging MMA carpark deck coating that provides colorful, waterproof and durable surface for exposed decks.

 

  • Rapid Curing, fast track application, can be overcoated without mechanical preparation.
  • Waterproof to as per AS 4654.1 waterproofing Membrane standard.
  • Crack bridging, flexible, solvent-free and used where elongation is critical.
  • Provides fire, slip, abrasion, UV and chemical resistance to carpark surfaces.
  • High textured noise reducing finish.
  • UV resistant
  • Low VOC.
  • Colourful and attractive coating system.
  • Non hazardous to health and environment.
  • Seamless, hygienic finish.

General information

Color

-

Manufacturer guidance

Wide range of colours available. Applicators responsibility to verify accuracy of colour prior to application. Check with the manufacturer's data sheet and instruction.

Finish

Satin.

Material

Methyl methacrylate

Warranty description

-

Manufacturer guidance

Guaranteed against defective materials and manufacture. Subject to Flowcrete standard ‘Warranty, Terms and Conditions of Sale. Check with manufacturer for details.

Uniclass

Ss_30_42_54_75 Resin flooring systemsPrimary

NATSPEC National Classification System

0657 Resin Based Seamless Flooring

SpeedSpec

03365 Concrete Finishes

SpecPack

07180 Traffic Coatings

Product range

Deckshield Car Park Coatings

Specification data - Resin flooring systems

Substrate preparation

-

Manufacturer guidance

Concrete should be finished by steel trowel. Surface preparation is to be completed by totally enclosed light shot blasting or course or diamond grinding to a minimum CSP3 prior to any coating application. For proper methods, refer to ICRI’s Technical Guideline No. 03732.

Reinforcement

-

Manufacturer guidance

Apply a band of Flowfast Primer, 50 mm wider than the reinforcing scrim. Allow to cure. Apply a band of Deckshield PDS Membrane. While still wet, apply Deckshield Scrim (Permafab), immediately followed by a second layer of Deckshield PDS Membrane. Allow to cure. Reinforce all horizontal and vertical junctions and gullies etc. as follows: Apply a band of Flowfast Primer and allow to cure. Apply a fillet of Dymonic 100 sealant to horizontal/vertical junction and allow to cure.

Standard

To AS 4654.1:2012.

Primer

Flowfast Primer @ 0.35 kg/m².

Manufacturer guidance

For coating application and instruction . To follow manufacturer's technical data sheet.

Membrane

Deckshield PDS membrane.

Guidance for specification option:

 Applied in two coats @ 0.6 kg/m² per coat. 

Binder

Apply Flowfast Flexible Binder mixed with SNL Filler.

Guidance for specification option:

Apply Flowfast Flexible Binder at 0.75kgm² mixed with SNL Filler at 0.75kgm².

Manufacturer guidance

For coating application and instruction . To follow manufacturer's technical data sheet.

Aggregate

24 Mesh White Aluminium Oxide Aggregate.

Sealer coat

Flowfast Flexible Sealer.

Guidance for specification option:

Applied in two coats. First coating @  0.45- 0.55kg/m², second coating @ 0.25- 0.35kg/m².

Manufacturer guidance

Rate dependent on aggregate. Follow manufacturer's instructions for application.

Colour

Bluebell.

Bridge Grey.

Dark Grey.

Light Grey Blue.

Light Grey.

Show more

Manufacturer guidance

Applicators responsibility to verify accuracy of colour prior to application. Refer to manufacturers' data sheets and instructions. For a full colour chart and sample requests, contact the manufacturer.

Finish:

Satin.

NominalThickness

4 mm.

6 mm.

Slip resistance

P5 (Based on 24 Mesh White Aluminium Oxide Aggregate).

Manufacturer guidance

Slip resistance value as per method describe in AS 4586.

UV resistance

UV stable.

Coving

-

Manufacturer guidance

Coving can form an integral part of the flooring system. It creates a sealed finish between the floor and wall joint. Please refer to Flowtex F1 Coving Mortar for further information.

Curing time

Foot traffic curing - 1 hour.

Full chemical cure between 2 hours to 3 hours.

Vehicular traffic between 2 hours to 3 hours.

Manufacturer guidance

Cure time per coating. Check and verify with the manufacturer.

Fire performance

To AS/ISO 9239.1.

Guidance for specification option:

Fire resistance to AS/ISO 9239.1.

Fire resistance

CHF Value 2.7 kW/m².

HF-30 Value 4.9 kW/m².

Smoke Value 226% (Mean).

VOC content

Less than 250 g/L.

Manufacturer guidance

Compliant with Green Star Design & As Built V1.2-13.1.1B, Green Star Interiors V1.2-12.1.1B.

Sustainability data

Country of product manufacture

Australia

Third party certifications

AWTA Test results

AWTA Test results

Deckshield ED Rapide AWTA Fire Test

Literature

Deckshield Brochure

Deckshield Brochure

Deckshield ED Rapide 4mm

Deckshield ED Rapide 4mm

Deckshield ED Rapide 6mm

Deckshield ED Rapide 6mm

Case studies

Waterproof Deck Coating Solution for Gawler Place

Waterproof Deck Coating Solution for Gawler Place

Similar products from Flowcrete

Deckcoat EP

Deckcoat EP

Flowcoat OP

Flowcoat OP

Flowcoat Terrosso

Flowcoat Terrosso

Flowfresh SR

Flowfresh SR

Flowshield ESD SL