NBS Source
I'm a manufacturer

Plus 60 Fire Barrier

Verified by manufacturer over a year ago

TBA Firefly

Flexible fire barrier used as a fire engineered solution to continue compartment walls up into the roof void.

Jump to:
+61754114209 Website

Application

TBA Firefly™ Plus 60 Fire Barrier is easy to install flexible fire barrier is used as a fire engineered solution to continue compartment walls up into the roof void, maintaining both the integrity and insulation of the compartmentation between dwellings, lift shafts and stairwells, ideal for but not limited to strata units.


Can also be used to provide inside out / outside in fire protection to boundary walls on both steel and timber framed buildings. The flexibility and fire rating level makes this product perfect for bespoke applications. 

Description

TBA Firefly™ Plus 60 Cavity Fire Barrier is a flexible and lightweight fabric with an inner core of insulating fire protection.


Also available with a fire rated silicone coating - Product Code FLYPLUS60RS

General information

Color

White

Finish

Flexible.

Material

Fabric.

Guidance for specification option:

With an inner core of insulating fire protection.

Length

6000 mm

Width

1300 mm

Uniclass

Pr_25_80_79_94 Vertical active fire curtain barriersPrimary

NATSPEC National Classification System

0182 Fire-Stopping

SpecPack

07810 Fireproofing

SpeedSpec

07810 Fireproofing

Specification data - Vertical active fire curtain barriers

Performance

-

Fire resistance level

-

Standard

To AS 1530.4- 2005.

To AS 4072.1-2005.

Manufacturer guidance

Exova Warringtonfire Report No: 22766.

Value

30/30/30.

-/60/30.

Fire hazard properties

-

Standard

To AS/NZS 1530.3.

Group number

3.

Dimensions

6000 l x 1300 w (mm).

Acoustic performance

46 dB.

Fabric thickness

10 mm.

Guidance for specification option:

2.2 kg per m².

Certification

CSIRO certified.

AWTA certified.

Guidance for specification option:

AS 1530.3 Simultaneous Determination of Ignitability, Flame Propagation, Heat Release and Smoke Release.

Exova Warringtonfire certified.

Fire testing - non combustibility

To AS 1530.1.

Guidance for specification option:

CSIRO Report No: FNC11220.

Support height

3000 mm.

Guidance for specification option:

Height between vertical support of barrier.

Similar products from TBA Firefly

Titan Fire Barrier

Titan Fire Barrier