OVERVIEW
A complete roof refurbishment, including thermal upgrade and full waterproofing of a church centre.
Systems in use
The project included various roof areas with different systems in situ, all requiring thermal upgrade, and increased falls to remove standing water from the roof. There were also rooflights and roof lanterns that needed to either be replaced or removed and boarded over, a live gas pipe which required lifting to accommodate the new roofing system, and various redundant SVP’s and chimneys.
Challenges
Three separate roof areas required upgrading as the existing waterproofing was failing and reaching the end of its service life. Water ingress was occurring, causing damage to the internals of the building.
Axter carried out in depth surveys and took various core samples to determine the existing build ups of each roof area. It was identified that remedial works were needed to stop water ingress, thermally upgrade the roof, remove standing water, and remove certain rooflights. Two out of the three areas had redundant and dated rooflights / roof lanterns. There was also an active gas pipe laid across the main roof area which had to be taken into consideration when specifying works.
Solutions
The 3 existing roof build ups included Asphalt with RBM cap sheet and stone chippings, Asphalt with RBM cap sheet and solar reflective paint and finally an EPDM system. Our core samples revealed that the areas with existing asphalt were in good condition. Therefore, Axter advised to only remove the solar reflective paint and the stone chippings to avoid the asphalt from going into landfill and to keep costs down. We used a mixture of torch applied and self-adhered AVCL’s, dependant on the deck type and to comply with SAFE2TORCH areas. Axter’s Ecoflex® ADH single ply membrane was the system of choice as this kept the use of naked flames to a minimum as the building remained in use throughout the refurbishment programme. The system provided a 20 Year Guarantee covering design, materials and workmanship and achieves Broof(T4) fire certification.
A live gas pipe was running across the main roof area. It was decided with the client that this would be replaced and raised to accommodate the new roofing system.
As this was a live site, the safety of the client and their visitors was a risk that needed to be considered. Risk and method statements were developed and written with the client’s ongoing activities in mind. The contract was carried out without the occurrence of any accidents or incidents.
Acknowledgments
We were delighted to have Axter and the Nautilus work on our roofing project and again were delighted with the outcomes. From initial consultations with both Nautilus and Axter we found them to be highly knowledgeable and professional in providing solutions and specifications. Axter’s attention to detail manifested through their survey work and their recommendations provided us with a great deal of assurance in the project, along with ongoing technical assistance from the Axter team to provide reassurance at different junctions in the project. Nautilus were extremely professional in their approach and a pleasure to have on site. Their high regard for health and safety and CDM on site was also evident and ensured a safe environment for all stakeholders. The project was completed by Nautilus in a timely manner and certified by Axter, giving us high confidence in the completed works. A real pleasure to work with on all sides.
Andy Lee , Vine Christian Centre
Ecoflex® FM Warm Roof Mechanically Fixed Single Ply System
Ecoflex® ADH Warm Roof Adhered Single Ply System
Bexley Park Sports & Social Club
West End Gate, London
Escapade Silverstone
Desborough Library
Flat roof overlay at historic lighthouse. Koster TPO Membrane.
Single Ply Warm Roof Waterproofing on Residential block of flats.
Koster Green Roof Waterproofing - Koster TPO Membrane
Museum of the Home, London. Koster TPO Single Ply Membrane.