QEC 11627; WRAS certified; Global GreenTag certified.
-
-
Water
Chilled and boiling.
-
-
Duty
-
-
-
Hot cups
Up to 250 per hour.
-
-
Cold cups
Up to 175 per hour.
-
-
Dimensions
Dispenser: 217 x 140 mm; outlet height: 137.5 mm.
-
-
Electrical connection
-
-
-
Power
A dedicated 20 A double-pole switched spur must be fitted at a high
level and accessible within the cupboard.
The unit comes with a 1 m flex cord and plug.
-
-
Water inlet
An accessible drinking water supply from a 15 mm pipe with a minimum pressure of 2.5 bar static and 6 litres-per-minute flow should be located in the base unit of the installation location.
-
-
Safety features
Lever control.
-
-
Additional properties
Colour
Chrome (CH)., Brushed (BR)., Matte Black (MB)., Matte White (MW)., Rose Gold (RG)., Brushed Rose Gold (BRG)., Gun Metal Grey (GM)., Urban Brass (UB).
-
-
Accessories
None., 120 mm riser and font (992803)., Tubing extension kit for X series dual temp dispensers (990720)., iX02 limescale filter (994032).
-
-
Integral accessories
Quadra under-bench unit with 800 mm tube. Premium filter.
-
-
Waste
A 32 mm/ 40 mm mains waste pipe is required within the base unit. This pipe should include a trap or U-bend to prevent any unpleasant odours. If there is a spigot waste connection, two spigots are required to connect to the waste and condenser line.