Summary
Self-limiting heating cable, for frost protection applications.
Self-limiting heating cable, for frost protection applications.
Self-limiting heating cable, for frost protection applications.
Application

Suitable for the frost protection of pipes within multiple indoor floor constructions.

Not approved for use in drinking water.

Suitable for the frost protection of pipes within multiple indoor floor constructions.

Not approved for use in drinking water.

Suitable for the frost protection of pipes within multiple indoor floor constructions.

Not approved for use in drinking water.

Description

Self-limiting heating cable with highly resistant outer sheath.

Features and benefits:

  • Can be cut to length on site (or drums can be supplied).
  • PVC free.
  • The self-limiting capability of the cable ensures that the output of the cable increases or decreases according to ambient temperature.
  • The cable will maintain its functionality even when shortened.
  • The outer sheath is highly resistant to harsh environmental conditions and corrosion, and it also serves as a protection against mechanical influences.
  • Compliant with DIN VDE 0254: 1994-06.

Note: The cables must be over-temperature protected by a thermostat.

Self-limiting heating cable with highly resistant outer sheath.

Features and benefits:

  • Can be cut to length on site (or drums can be supplied).
  • PVC free.
  • The self-limiting capability of the cable ensures that the output of the cable increases or decreases according to ambient temperature.
  • The cable will maintain its functionality even when shortened.
  • The outer sheath is highly resistant to harsh environmental conditions and corrosion, and it also serves as a protection against mechanical influences.
  • Compliant with DIN VDE 0254: 1994-06.

Note: The cables must be over-temperature protected by a thermostat.

Self-limiting heating cable with highly resistant outer sheath.

Features and benefits:

  • Can be cut to length on site (or drums can be supplied).
  • PVC free.
  • The self-limiting capability of the cable ensures that the output of the cable increases or decreases according to ambient temperature.
  • The cable will maintain its functionality even when shortened.
  • The outer sheath is highly resistant to harsh environmental conditions and corrosion, and it also serves as a protection against mechanical influences.
  • Compliant with DIN VDE 0254: 1994-06.

Note: The cables must be over-temperature protected by a thermostat.

Product certifications
Digital objects
Color
Blue, Red, Brown
Blue, Red, Brown
Blue, Red, Brown
Material
Thermoplastic elastomer (TPE), Copper, Polyolefin
Thermoplastic elastomer (TPE), Copper, Polyolefin
Thermoplastic elastomer (TPE), Copper, Polyolefin
Shape
Other
Other
Other
Length
305000 mm, 800000 mm, Bespoke
305000 mm, 800000 mm, Bespoke
305000 mm, 800000 mm, Bespoke
Width
11.8 mm
11.8 mm
11.8 mm
Height
5.8 mm
5.8 mm
5.8 mm
Warranty description
Five year
Five year
Five year
SKU Code
140F8504, 140F8505, 140F8506
140F8504, 140F8505, 140F8506
140F8504, 140F8505, 140F8506

Specification

Maximum withstand temperature
-
-
-
Power on
65°C.
65°C.
65°C.
Power off
85°C.
85°C.
85°C.
Power output
10 W/m at 10°C.
25 W/m at 10°C.
33 W/m at 10°C.
Voltage rating
230 V a.c.
230 V a.c.
230 V a.c.
Cable construction
-
-
-
Conductors
Nickel-plated copper.
Nickel-plated copper.
Nickel-plated copper.
Electrically conductive covering
Tinned copper braid.
Tinned copper braid.
Tinned copper braid.
Overjacket
Polyolefin.
Polyolefin.
Polyolefin.

Additional properties

Colour
Blue.
Red.
Brown.
Ingress protection (minimum)
IPX7.
IPX7.
IPX7.
Insulation
Radiation cross-linked, primary dielectric insulation.
Radiation cross-linked, primary dielectric insulation.
Radiation cross-linked, primary dielectric insulation.
Cable length
800 m maximum, cut-to-size.
800 m maximum, cut-to-size.
305 m maximum, cut-to-size.
Installation temperature
-5°C (minimum).
-5°C (minimum).
-5°C (minimum).

Sustainability data

Country of product manufacture
Germany
Germany
Germany
Material
Thermoplastic elastomer (TPE), Copper, Polyolefin
Thermoplastic elastomer (TPE), Copper, Polyolefin
Thermoplastic elastomer (TPE), Copper, Polyolefin
A1–A3 ('Production stage')

Embodied carbon as defined in BS EN 15804

Normalized unit
-
-
-
Declared unit
0.43 kg CO₂ eq/unit

Certified

0.43 kg CO₂ eq/unit

Certified

0.43 kg CO₂ eq/unit

Certified