NBS Source
I'm a manufacturer

Compare variants

SPW600e Tilt/Turn Window
SPW600e Tilt/Turn Window

Verified 3 months ago

Senior Architectural Systems Ltd

SPW600e Tilt/ Turn Window System [Curtain Wall Placement]

Verified 3 months ago

Senior Architectural Systems Ltd

SPW600e Tilt/ Turn Window System [Wall Placement]

Summary
A three chamber aluminium, 75 mm polyamide tilt/ turn window system that achieves impressive thermal performance.
A three chamber aluminium, 75 mm polyamide tilt/ turn window system that achieves impressive thermal performance.
Application

Suitable for educational, commercial and retail applications, transport terminals, health service buildings.

Suitable for educational, commercial and retail applications, transport terminals, health service buildings.

Description

Three chamber 75 mm polyamide window system which achieved good thermal performance. An enhancement to the SPW 600 Suite of windows which introduces a polystyrene strip in the thermal break cavity alongside a backer rod situated around the insulated glazed unit (IGU) ensure the window exceeds the rigorous standards set in the Building Regulation (E&W) Approved Document L.


Performance:

  • Air permeability: 600 Pa.
  • Watertightness: 600 Pa.
  • Wind resistance: 2400 Pa.
  • Carries a Window Energy Rating (WER) of A–C.


Size limitations:

  • Vent height: 520–2400 mm.
  • Vent width: 465–1500 mm.
  • Maximum weight: 130 kg/ 150 kg.


Features and benefits:

  • Includes a polystyrene strip in the thermal break cavity alongside a backer rod situated around the insulated glazed unit.
  • Polyamide thermal barriers are manufactured in accordance with PA66 GF25.
  • Gaskets are manufactured in accordance with BS 3734.


Construction:

Constructed with mitred and mechanically crimped or joined corners, with support chevrons and cleats to ensure accurate alignment. Integral transoms and mullions are fixed into the outer frames with screws or brackets. Joints are sealed against water ingress during assembly. Opening lights are inserted directly into the outer frames on butt hinges or friction stays. Vent frames can be fixed directly into the framing modules. Individual modules can be fully assembled and then transported to site. The windows incorporate an integral polyamide thermal break.

Three chamber 75 mm polyamide window system which achieved good thermal performance. An enhancement to the SPW 600 Suite of windows which introduces a polystyrene strip in the thermal break cavity alongside a backer rod situated around the insulated glazed unit (IGU) ensure the window exceeds the rigorous standards set in the Building Regulation (E&W) Approved Document L.


Performance:

  • Air permeability: 600 Pa.
  • Watertightness: 600 Pa.
  • Wind resistance: 2400 Pa.
  • Carries a Window Energy Rating (WER) of A–C.


Size limitations:

  • Vent height: 520–2400 mm.
  • Vent width: 465–1500 mm.
  • Maximum weight: 130 kg/ 150 kg.


Features and benefits:

  • Includes a polystyrene strip in the thermal break cavity alongside a backer rod situated around the insulated glazed unit.
  • Polyamide thermal barriers are manufactured in accordance with PA66 GF25.
  • Gaskets are manufactured in accordance with BS 3734.


Construction:

Constructed with mitred and mechanically crimped or joined corners, with support chevrons and cleats to ensure accurate alignment. Integral transoms and mullions are fixed into the outer frames with screws or brackets. Joints are sealed against water ingress during assembly. Opening lights are inserted directly into the outer frames on butt hinges or friction stays. Vent frames can be fixed directly into the framing modules. Individual modules can be fully assembled and then transported to site. The windows incorporate an integral polyamide thermal break.

Digital objects
Finish
Anodized, Powder-coated
Anodized, Powder-coated
Material
Aluminium
Aluminium
Length
Bespoke
Bespoke
Width
Bespoke
Bespoke
Height
Bespoke
Bespoke

Specification

Classification data
Standard
To BS 3734, B S6375-1:2015, BS 6375-2:2009 & PAS24:2016.
To BS 3734, B S6375-1:2015, BS 6375-2:2009 & PAS24:2016.
Third-party certification
Third-party-accredited by a UKAS-approved or recognized body.
Third-party-accredited by a UKAS-approved or recognized body.
Dimensions and configurations
As drawing., As schedule.
As drawing., As schedule.
Product performance
-
-
Weather performance
-
-
UK exposure category
2400 Pa.
2400 Pa.
Air permeability
600 Pa (Class C).
600 Pa (Class C).
Watertightness
600 Pa.
600 Pa.
Resistance to wind load
2400 Pa.
2400 Pa.
Durability
-
-
Operation and strength characteristics
Tested to BS 6375-2:2009.
Tested to BS 6375-2:2009.
Safety
-
-
Security level
Tested to PAS 24:2016 Enhanced Security.
Tested to PAS 24:2016 Enhanced Security.
Thermal
-
-
British Fenestration Rating Council Window Energy Rating
A–C.
A–C.
Frame
-
-
Finish as delivered
-
-
Coating
Anodized., Polyester powder coated.
Anodized., Polyester powder coated.
Glazing or infill
-
-
Requirements
Insulated glass unit, inside glazed., Insulated glass unit, outside glazed.
Insulated glass unit, inside glazed., Insulated glass unit, outside glazed.

Additional properties

Type
Tilt/ turn., Turn only., French casement., Turn only French casement.
Tilt/ turn., Turn only., French casement., Turn only French casement.
Ironmongery/ Accessories
Manufacturer's standard., Non-locking handle., Locking handle.
Manufacturer's standard., Non-locking handle., Locking handle.
PlacementType
Curtain wall placement.
Wall placement.

Sustainability data

Country of product manufacture
United Kingdom
United Kingdom