NBS Source
I'm a manufacturer

Compare variants

MSA Latchways Walkway WalkSafe® - Rooftop Walkway
MSA Latchways Walkway WalkSafe® - Rooftop Walkway
MSA Latchways Walkway WalkSafe® - Rooftop Walkway

Verified 4 months ago

MSA Safety (Latchways)

WalkSafe® – Flat

Verified 4 months ago

MSA Safety (Latchways)

WalkSafe® – Half valley

Verified 4 months ago

MSA Safety (Latchways)

WalkSafe® – Valley

Summary
Walkway designed suitable for Standing Seam, Composite, BUOS and Membrane roof finishes. WalkSafe provides a level, anti-slip surface and can prevent damage to the roofing finish. Fully BBA Certified.
Walkway designed suitable for Standing Seam, Composite, BUOS and Membrane roof finishes. WalkSafe provides a level, anti-slip surface and can prevent damage to the roofing finish. Fully BBA Certified.
Walkway designed suitable for Standing Seam, Composite, BUOS and Membrane roof finishes. WalkSafe provides a level, anti-slip surface and can prevent damage to the roofing finish. Fully BBA Certified.
Application

Designed to provide a level, anti-slip means of traversing roofs.

Suitable for use on:

  • Standing seam.
  • Composite panels.
  • Built up on site metal roofing.
  • Secret fix metal roofing.
  • Membrane roofing to various substrates.

Designed to provide a level, anti-slip means of traversing roofs.

Suitable for use on:

  • Standing seam.
  • Composite panels.
  • Built up on site metal roofing.
  • Secret fix metal roofing.
  • Membrane roofing to various substrates.

Designed to provide a level, anti-slip means of traversing roofs.

Suitable for use on:

  • Standing seam.
  • Composite panels.
  • Built up on site metal roofing.
  • Secret fix metal roofing.
  • Membrane roofing to various substrates.
Description

A range of walkways designed to provide a level, anti-slip means of traversing roofs – including corrugated and standing seam roof constructions – for access and maintenance. A safety tread incorporated in the top plank provides safe footing, even in wet conditions.


WalkSafe® modular panels are manufactured, to order, from extruded unplasticized polyvinyl chloride (PVC-U). The panels are clipped together on-site using integral fasteners. Fixing through the roof membrane is not required under normal conditions.


When used on flat roofs, the roof deck must comply with BS 629. When used over roof waterproofing membranes, the waterproofing layer should have a minimum static indentation rating of L3, when tested to MOAT No 27:1983, to ensure sufficient resistance to damage.


Accessories include:

  • Fall-proof covers: When used over fragile roofing materials in roof valleys or at parapets and north-light roofs, provide suitable protection to the material, enabling it to meet the requirements of CDM Regulations and the recommendations of HS/ G33 'Health and Safety in Roof Work'.
  • Rooflight covers: Provide passive/ collective protection where access close to potentially fragile roof lights is required.

A range of walkways designed to provide a level, anti-slip means of traversing roofs – including corrugated and standing seam roof constructions – for access and maintenance. A safety tread incorporated in the top plank provides safe footing, even in wet conditions.


WalkSafe® modular panels are manufactured, to order, from extruded unplasticized polyvinyl chloride (PVC-U). The panels are clipped together on-site using integral fasteners. Fixing through the roof membrane is not required under normal conditions.


When used on flat roofs, the roof deck must comply with BS 629. When used over roof waterproofing membranes, the waterproofing layer should have a minimum static indentation rating of L3, when tested to MOAT No 27:1983, to ensure sufficient resistance to damage.


Accessories include:

  • Fall-proof covers: When used over fragile roofing materials in roof valleys or at parapets and north-light roofs, provide suitable protection to the material, enabling it to meet the requirements of CDM Regulations and the recommendations of HS/ G33 'Health and Safety in Roof Work'.
  • Rooflight covers: Provide passive/ collective protection where access close to potentially fragile roof lights is required.

A range of walkways designed to provide a level, anti-slip means of traversing roofs – including corrugated and standing seam roof constructions – for access and maintenance. A safety tread incorporated in the top plank provides safe footing, even in wet conditions.


WalkSafe® modular panels are manufactured, to order, from extruded unplasticized polyvinyl chloride (PVC-U). The panels are clipped together on-site using integral fasteners. Fixing through the roof membrane is not required under normal conditions.


When used on flat roofs, the roof deck must comply with BS 629. When used over roof waterproofing membranes, the waterproofing layer should have a minimum static indentation rating of L3, when tested to MOAT No 27:1983, to ensure sufficient resistance to damage.


Accessories include:

  • Fall-proof covers: When used over fragile roofing materials in roof valleys or at parapets and north-light roofs, provide suitable protection to the material, enabling it to meet the requirements of CDM Regulations and the recommendations of HS/ G33 'Health and Safety in Roof Work'.
  • Rooflight covers: Provide passive/ collective protection where access close to potentially fragile roof lights is required.
Product certifications
Digital objects
Color
White, Silver
White, Silver
White, Silver
Finish
-
-
-
Material
PVC-U
PVC-U
PVC-U
Shape
Rectangle
Rectangle
Rectangle
Length
3000 mm, Bespoke
3000 mm, Bespoke
3000 mm, Bespoke
Width
600 mm
600 mm
600 mm
Warranty description
25 year
25 year
25 year

Specification

Classification data
Decking and flooring
-
-
-
Material
Manufacturer's standard.
Manufacturer's standard.
Manufacturer's standard.
Applied anti-slip treatment
Manufacturer's standard.
Manufacturer's standard.
Manufacturer's standard.
System accessories
Fall-proof cover., Rooflight cover.
Fall-proof cover., Rooflight cover.
Fall-proof cover., Rooflight cover.

Additional properties

Colour
Brown., Silver grey., White.
Brown., Silver grey., White.
Brown., Silver grey., White.
Fire performance
To BS 476-7, class 1Y.
To BS 476-7, class 1Y.
To BS 476-7, class 1Y.
Type
Flat.
Half valley.
Valley.

Sustainability data

Country of material origin
United Kingdom
United Kingdom
United Kingdom
Country of product manufacture
United Kingdom
United Kingdom
United Kingdom
Material
PVC-U
PVC-U
PVC-U
Recyclability
Fully recyclable
Fully recyclable
Fully recyclable
Recycled content
100 %
100 %
100 %