NBS Source
I'm a manufacturer

Compare variants

Bauder LiquiTOP Insulated System - Cold Applied
Bauder LiquiTOP Insulated System - Cold Applied

Verified 8 months ago

Bauder Ltd

LiquiTOP 3COAT System

Verified 8 months ago

Bauder Ltd

LiquiTOP System

Summary
Cold liquid applied, warm roof system suitable for new build and refurbishment applications.
Cold liquid applied, warm roof system suitable for new build and refurbishment applications.
Third party certification
Digital objects
Color
Grey
Grey
Finish
Smooth
Smooth
Material
Polyurethane
Polyurethane
Shape
Formless
Formless
Length
Bespoke
Bespoke
Width
Bespoke
Bespoke

Specification

System performance
Warm roof system.
Warm roof system.
Preparation
-
-
Horizontal work
Bauder SA Bonding Primer., Bauder Activator Primer.
Bauder SA Bonding Primer., Bauder Activator Primer.
Skirtings and vertical work
Relevant LiquiTOP Primer.
Relevant LiquiTOP Primer.
Air and vapour control layer
TEC DBR 06., KSD FBS.
TEC DBR 06., KSD FBS.
Insulation
-
-
Type
PIR FA-TE Flatboard Insulation., BauderPIR FA G16 foil-faced tapered insulation.
PIR FA-TE Flatboard Insulation., BauderPIR FA G16 foil-faced tapered insulation.
Carrier membrane
-
-
Type
DBR 06 Carrier membrane.
DBR 06 Carrier membrane.
Liquid-applied waterproofing
-
-
Type
Bauder LiquiTOP PU, three coats.
Bauder LiquiTOP PU, two coats.
Reinforcement
Bauder LiquiTOP Glass Fibre Mat.
Bauder LiquiTOP Glass Fibre Mat.
System accessories
Bauder GRP Water Check Trim., Bauder 100/60 GRP Trim Angle., BauderPVC ABL-R 75, vertical outlets., BauderPVC ABL-R 110, vertical outlets., BauderPVC ABL-R 160, vertical outlets., BauderSYN KFK-R UNI universal leaf guard for vertical outlets., BauderPVC NLF-R 50 emergency overflow., Bauder Lightning Conductor Clips., Bauder Rooflights., None.
Bauder GRP Water Check Trim., Bauder 100/60 GRP Trim Angle., BauderPVC ABL-R 75, vertical outlets., BauderPVC ABL-R 110, vertical outlets., BauderPVC ABL-R 160, vertical outlets., BauderSYN KFK-R UNI universal leaf guard for vertical outlets., BauderPVC NLF-R 50 emergency overflow., Bauder Lightning Conductor Clips., Bauder Rooflights., None.

Additional properties

Fire performance
To DD CEN/TS 1187 (test 4)/ EN 13501-5, BROOF(t4).
To DD CEN/TS 1187 (test 4)/ EN 13501-5, BROOF(t4).
Colour:
Dark Grey RAL 7011., Mist Grey RAL 7040.
Dark Grey RAL 7011., Mist Grey RAL 7040.