NBS Source
I'm a manufacturer

Compare variants

VMZINC Standing Seam Cold Roofing - Vented Cold Roof System
VMZINC Standing Seam Cold Roofing - Vented Cold Roof System

Verified 2 months ago

VMZINC UK

Standing seam roof on open gap boarding (cold, vented)

Verified 2 months ago

VMZINC UK

Standing seam roof on plywood (cold, vented)

Summary
Vented cold roof systems for buildings with humidity classes between 1 and 4 using VMZINC on an open gap softwood boarding (compatible) substrate.
Vented cold roof systems for buildings with humidity classes between 1 and 4 using VMZINC on an open gap softwood boarding (compatible) substrate.
Application

Suitable for buildings in 1 to 4 humidity classes (dwellings with high occupancy, sport halls, etc) with pitches from 3° to the vertical (as well as soffits).

Suitable for buildings in 1 to 4 humidity classes (dwellings with high occupancy, sport halls, etc) with pitches from 3° to the vertical (as well as soffits).

Description

Vented cold roof systems for buildings with humidity classes between 1 and 4 using VMZINC on an open gap softwood boarding (compatible) substrate.

Standing Seam Roof on open gap boarding (cold, vented):

  • Vented cold roof system for buildings with humidity classes between 1 and 4 using VMZINC on an open gap softwood boarding (compatible) substrate.
  •  A minimum 50 mm continuous air gap must be left clear beneath the roof boarding. Continuous ventilation openings are made at the ridge and eaves. In order to maintain the integrity of the roof, a VMZINC breather membrane should be installed on the cold side of the insulation, and a vapour control layer appropriate to the building’s humidity levels laid on the warm side of the insulation.
  • VMZINC must be installed directly over the open-gap softwood boarding without the use of any membrane. The boarding should be clean and dry, 100–150 mm wide, 18 or 24 mm thick, according to the rafter centres.
  • The roof boards are fixed perpendicularly to the direction of the pitch leaving a 3–5 mm gap between them. They are securely fixed to the structure.

Features and benefits:

  • A very versatile and easy to install substrate.
  • Flexible because it also permits complex shapes to be clad in zinc.
  • Excellent pull-out resistance.
  • Easy installation using traditional clips.
  • BRE EN 15804 EPD.

System build-up:

  • Interior finish;
  • Vapour control layer;
  • Insulation;
  • VMZINC Membrane;
  • 50 mm ventilated air space (minimum);
  • Rafter;
  • Batten;
  • Open-gap timber boarding;
  • VMZINC Standing Seam.

____________________________________________________________________________

Standing Seam Roof on plywood (cold, vented):

  • Vented cold roof system for buildings with humidity classes between 1 and 4 using VMZINC Plus on a plywood (non-compatible) substrate.
  • VMZINC PLUS is installed on the plywood. A minimum 50 mm continuous air gap must be left clear beneath the plywood. Continuous ventilation openings are made at the ridge and eaves at least 10 mm wide protected by insect mesh and correspond to BS 5250: 2002.
  •  VMZINC Membrane can be used between the VMZINC PLUS and the plywood, although this is optional but may have the advantage of protecting the plywood prior to the installation of the zinc. The ideal thickness of the plywood is 18 mm and it must be weather and boil proof. WBP plywood is more precisely described as EN 314-2 (bond class 2) and EN 636-2 (timber performance).
  • It is also recommended to install a vapour control layer on the warm side of the insulation.

Features and benefits:

  • Provides a continuous rigid deck for the VMZINC PLUS.
  • Plywood decking is readily available and widely used.
  • Excellent pull-out resistance.
  • BRE EN 15804 EPD.

System build-up:

  • Interior finish;
  • Vapour control layer;
  • Insulation;
  • VMZINC Membrane;
  • 50 mm ventilated air space (minimum);
  • Rafter;
  • Batten;
  • Plywood;
  • VMZINC PLUS Standing Seam.

VMZINC PLUS:

A product which allows zinc to be installed on ventilated plywood as well as specific warm (non-ventilated) substrates. The product consists of VMZINC (in all finishes) having a 60 µm coating applied to the underside thus allowing a more varied amount of substrates to be used and eliminating the risk of the formation of white rust on the underside of the zinc standing seam panels. VMZINC PLUS resists to an abrasion of 140 L when tested in accordance with ASTM D 968.

____________________________________________________________________________

Life Cycle Analysis (LCA):

VMZINC undertakes Life Cycle Analysis (LCA) tests on its products and publishes Environmental Product Declarations (EPDs), such as BRE Environmental Profiles. These provide users with comprehensive, reliable and transparent information on relevant environmental characteristics. The information is also used by VMZINC as the basis for its eco-design approach.

Vented cold roof systems for buildings with humidity classes between 1 and 4 using VMZINC on an open gap softwood boarding (compatible) substrate.

Standing Seam Roof on open gap boarding (cold, vented):

  • Vented cold roof system for buildings with humidity classes between 1 and 4 using VMZINC on an open gap softwood boarding (compatible) substrate.
  •  A minimum 50 mm continuous air gap must be left clear beneath the roof boarding. Continuous ventilation openings are made at the ridge and eaves. In order to maintain the integrity of the roof, a VMZINC breather membrane should be installed on the cold side of the insulation, and a vapour control layer appropriate to the building’s humidity levels laid on the warm side of the insulation.
  • VMZINC must be installed directly over the open-gap softwood boarding without the use of any membrane. The boarding should be clean and dry, 100–150 mm wide, 18 or 24 mm thick, according to the rafter centres.
  • The roof boards are fixed perpendicularly to the direction of the pitch leaving a 3–5 mm gap between them. They are securely fixed to the structure.

Features and benefits:

  • A very versatile and easy to install substrate.
  • Flexible because it also permits complex shapes to be clad in zinc.
  • Excellent pull-out resistance.
  • Easy installation using traditional clips.
  • BRE EN 15804 EPD.

System build-up:

  • Interior finish;
  • Vapour control layer;
  • Insulation;
  • VMZINC Membrane;
  • 50 mm ventilated air space (minimum);
  • Rafter;
  • Batten;
  • Open-gap timber boarding;
  • VMZINC Standing Seam.

____________________________________________________________________________

Standing Seam Roof on plywood (cold, vented):

  • Vented cold roof system for buildings with humidity classes between 1 and 4 using VMZINC Plus on a plywood (non-compatible) substrate.
  • VMZINC PLUS is installed on the plywood. A minimum 50 mm continuous air gap must be left clear beneath the plywood. Continuous ventilation openings are made at the ridge and eaves at least 10 mm wide protected by insect mesh and correspond to BS 5250: 2002.
  •  VMZINC Membrane can be used between the VMZINC PLUS and the plywood, although this is optional but may have the advantage of protecting the plywood prior to the installation of the zinc. The ideal thickness of the plywood is 18 mm and it must be weather and boil proof. WBP plywood is more precisely described as EN 314-2 (bond class 2) and EN 636-2 (timber performance).
  • It is also recommended to install a vapour control layer on the warm side of the insulation.

Features and benefits:

  • Provides a continuous rigid deck for the VMZINC PLUS.
  • Plywood decking is readily available and widely used.
  • Excellent pull-out resistance.
  • BRE EN 15804 EPD.

System build-up:

  • Interior finish;
  • Vapour control layer;
  • Insulation;
  • VMZINC Membrane;
  • 50 mm ventilated air space (minimum);
  • Rafter;
  • Batten;
  • Plywood;
  • VMZINC PLUS Standing Seam.

VMZINC PLUS:

A product which allows zinc to be installed on ventilated plywood as well as specific warm (non-ventilated) substrates. The product consists of VMZINC (in all finishes) having a 60 µm coating applied to the underside thus allowing a more varied amount of substrates to be used and eliminating the risk of the formation of white rust on the underside of the zinc standing seam panels. VMZINC PLUS resists to an abrasion of 140 L when tested in accordance with ASTM D 968.

____________________________________________________________________________

Life Cycle Analysis (LCA):

VMZINC undertakes Life Cycle Analysis (LCA) tests on its products and publishes Environmental Product Declarations (EPDs), such as BRE Environmental Profiles. These provide users with comprehensive, reliable and transparent information on relevant environmental characteristics. The information is also used by VMZINC as the basis for its eco-design approach.

Product certifications
Digital objects
Color
Blue, Green, Grey, Red, Brown
Blue, Green, Grey, Red, Brown
Finish
Natural, Pre-treated
Natural, Pre-treated
Material
Zinc
Zinc
Shape
Rectangle, Other
Rectangle, Other
Length
13000 mm, Bespoke
13000 mm, Bespoke
Width
430 mm, 530 mm, 600 mm, Bespoke
430 mm, 530 mm, 600 mm, Bespoke
Height
25 mm
25 mm
Warranty description
50 year
50 year

Specification

Classification data
System performance
Structural performance – wind actions, Design of zinc sheet fully supported roof covering systems, Durability, Aesthetic performance, Fire performance
Structural performance – wind actions, Design of zinc sheet fully supported roof covering systems, Durability, Aesthetic performance, Fire performance
Sarking or roof boarding
18 mm open gap softwood boards.
18 mm plywood - EN 314 bond class 2 and EN 636-2 timber performance.
Membrane
VMZINC Membrane.
VMZINC Membrane.
Insulation
As required.
As required.
Air and vapour control layer
-
-
Carrier
Batten (rafters can be metal or timber).
Batten.
Substrate
Not applicable.
Plywood.
Sheet underlay
-
-
Fasteners
Screws as required.
Screws as required.
Zinc
Zinc-titanium-copper (VMZINC®), 0.7 mm thick., Zinc-titanium-copper (VMZINC®), 0.8 mm thick.
Zinc-titanium-copper (VMZINC® PLUS), 0.7 mm thick., Zinc-titanium-copper (VMZINC® PLUS), 0.8 mm thick.
Longitudinal joints
-
-
Form
Standing seam joints.
Standing seam joints.
Fixing standing seam joints
VMZINC clips, 1.4301 (304) stainless steel. The thickness of the fixing clip is 0.5 mm. The sliding clips have a moving component, which is 0.4 mm thick, and a 70 mm long slot.
VMZINC clips, 1.4301 (304) stainless steel. The thickness of the fixing clip is 0.5 mm. The sliding clips have a moving component, which is 0.4 mm thick, and a 70 mm long slot.
Fasteners to substrate
It is recommended that screws be used to secure the clips with three being used per sliding clip. The use of nails offers significantly less resistance, but in the event of using nails, contractors are advised to use ring shank nails.
It is recommended that screws be used to secure the clips with three being used per sliding clip. The use of nails offers significantly less resistance, but in the event of using nails, contractors are advised to use ring shank nails.
Cross joints
-
-
Form
Double lock welts., Roof steps.
Double lock welts., Roof steps.
Eave details
-
-
Form
Dog tooth., Swept eave on 'T' plate with water check.
Dog tooth., Swept eave on 'T' plate with water check.
Fixings
Fixed with cleats using a 6 mm rebate on the substrate.
Fixed with cleats using a 6 mm rebate on the substrate.
Verge details
-
-
Form
Standing seam verge.
Standing seam verge.
Fixing
-
-
Top edge
VMZINC stainless steel sliding clip.
VMZINC stainless steel sliding clip.
Bottom edge
The eave should be fixed to a 'T' plate with water check which must be secured using cleats.
The eave should be fixed to a 'T' plate with water check which must be secured using cleats.
Ridge and hip details
-
-
Form
G3 ridge., Traditional with upstand.
G3 ridge., Traditional with upstand.
Fixings
Ridge clip G3.
Ridge clip G3.

Additional properties

Colour
Natural VMZINC®, natural finish., Standard PIGMENTO® BLUE., Standard PIGMENTO® GREEN., Standard PIGMENTO® BROWN., Standard PIGMENTO® RED., Standard PIGMENTO® GREY., PIGMENTO® STORM GREY., PIGMENTO® CHARCOAL GREY., QUARTZ-ZINC®., ANTHRA-ZINC®., AZENGAR®.
Natural VMZINC®, natural finish., Standard PIGMENTO® BLUE., Standard PIGMENTO® GREEN., Standard PIGMENTO® BROWN., Standard PIGMENTO® RED., Standard PIGMENTO® GREY., PIGMENTO® STORM GREY., PIGMENTO® CHARCOAL GREY., QUARTZ-ZINC®., ANTHRA-ZINC®., AZENGAR®.
Panel length
-
-
Panel width
430 mm., 530 mm., 600 mm.
430 mm., 530 mm., 600 mm.
Custom design
Not required., Required.
Not required., Required.
Standard
To EN 15804, ISO 14001 and ISO 9001.
To EN 15804, ISO 14001 and ISO 9001.
Panel weight
6 kg/m² (approximately).
6 kg/m² (approximately).
Reaction to fire
Fire classification according to EN 13501-1:2002:
A1 (Natural Zinc/ QUARTZ ZINC/ ANTHRA-ZINC/ AZENGAR);
A2-s1,d0 (PIGMENTO and VMZINC).
Fire classification according to EN 13501-1:2002:
A1 (Natural Zinc/ QUARTZ ZINC/ ANTHRA-ZINC/ AZENGAR);
A2-s1,d0 (PIGMENTO and VMZINC PLUS).
Slope
Minimum 3%.
Minimum 3%.

Sustainability data

Contains Red List materials
No
No
Country of material origin
France
France
Country of product manufacture
France
France
Material
Zinc
Zinc
Recyclability
100%
100%
Recycled content
20 %
20 %
Expected Life
100 year
100 year