Pyrobel T Vision Line
Pyrobel T Vision Line
Pyrobel T Vision Line

Verified 5 months ago

AGC Glass UK Ltd

Pyrobel-T EI60-34 VL

Verified 5 months ago

AGC Glass UK Ltd

Pyrobel-T EI30-22 VL

Verified 5 months ago

AGC Glass UK Ltd

Pyrobel-T EI30-27 VL

Summary
Butt-jointed system using multiple panes of Pyrobel T clear laminated fire-resistant safety glass.
Butt-jointed system using multiple panes of Pyrobel T clear laminated fire-resistant safety glass.
Butt-jointed system using multiple panes of Pyrobel T clear laminated fire-resistant safety glass.
Color
Clear
Clear
Clear
Material
Glass
Glass
Glass
Length
Bespoke
Bespoke
Bespoke
Width
Bespoke
Bespoke
Bespoke
Height
Bespoke
Bespoke
Bespoke

Specification

General requirements
Glass generally.
Glass generally.
Glass generally.
Third-party certification
Certifire CF 5746.
Certifire CF 5746.
Certifire CF 5746.
Laminate glass type
Fire and safety.
Fire and safety.
Fire and safety.
Thickness
34.0 mm.
22.0 mm.
26.8 mm.
Outer leaf
Manufacturer's standard.
Manufacturer's standard.
Manufacturer's standard.
Inner leaf
Manufacturer's standard.
Manufacturer's standard.
Manufacturer's standard.
Interlayer to glass leaves
Manufacturer's standard.
Manufacturer's standard.
Manufacturer's standard.
Body colour
Clear., Extra clear (Clearvision).
Clear., Extra clear (Clearvision).
Clear., Extra clear (Clearvision).
Pattern
Transparent.
Transparent.
Transparent.
Performance requirements
-
-
-
Fire resistance
-
-
-
Integrity
To BS EN 13501-2, E 60 minutes.
To BS EN 13501-2, E 30 minutes.
To BS EN 13501-2, E 30 minutes.
Insulation
To BS EN 13501-2, EI 60 minutes.
To BS EN 13501-2, EI 30 minutes.
To BS EN 13501-2, EI 30 minutes.
Light
Transmission: 81%; Reflection: 8%.
Transmission: 87%; Reflection: 9%.
Transmission: 84%; Reflection: 8%.
Sound attenuation
To EN 12758 Rw (C; Ctr): 42 (-2; -2) dB.
To EN 12758 Rw (C; Ctr): 39 (-1; -3) dB.
To EN 12758 Rw (C; Ctr): 40 (-2; -2) dB.
Impact resistance
To BS EN 12600, 1B1.
To BS EN 12600, 1B1.
To BS EN 12600, 1B1.

Additional properties

Overall size
-
-
-
Thermal conductivity
To EN 673, 5.0 W/m²K.
To EN 673, 5.2 W/m²K.
To EN 673, 5.1 W/m²K.
Grades
Internal.
Internal.
Internal.
Average panel weight
75 kg/m².
49 kg/m².
60 kg/m².

Sustainability data

Contains Red List materials
No
No
No
Country of material origin
Europe
Europe
Europe
Country of product manufacture
Europe
Europe
Europe
Recyclability
100%
100%
100%