NBS Source
I'm a manufacturer

Compare variants

Corner Protection Angle - Corner Guards
Corner Protection Angle - Corner Guards

Verified 23 days ago

Yeoman Shield, trading name of Harrison Thompson & Co Ltd

Standard corner protectors

Verified 23 days ago

Yeoman Shield, trading name of Harrison Thompson & Co Ltd

Trims

Summary
Corner protection angle providing protection to vulnerable corners.
Corner protection angle providing protection to vulnerable corners.
Application

Suitable for use in hospitals, supermarkets, nursing homes, schools, banks, airports, offices and any other areas which are subject to damage by impact or abrasion.

Suitable for use in hospitals, supermarkets, nursing homes, schools, banks, airports, offices and any other areas which are subject to damage by impact or abrasion.

Description

Yeoman Shield Corner Protection Angles and Trims provide protection to vulnerable corners from impact damage caused by either vehicular or pedestrian traffic and are available in a range of sizes and materials. Corner Protection Angles and Trims are suitable for use in hospitals, supermarkets, nursing homes, schools, banks, airports, offices and any other areas which are subject to damage by impact or abrasion.

Consult manufacturer for fixing instructions.

Approvals:

Extruded Textured Material fire tested to:

  • B-s2,d0.
  • BS EN 13823:2010 + A1:2014.
  • BS EN ISO 11925 - 2: 2010.
  • BS EN 13501 - 1: 2007 + A1:2009.
  • BS 476: Part 7: 1997 - The surface spread of flame of products - Class 1Y.
  • BS 476: Part 6: 1989 + A1:2009- Fire propagation for products - Class 0 - As defined in the latest Building Regulations, Approved Document B (Fire Safety).

VOC Emissions

Yeoman Shield PVC-U Falmouth Wall & Door Protection panels have been tested for VOC to ISO 16000-10:2006 Indoor air - Part 10.

 The test showed the following results:

  •  <10 µg/m²h for TVOC.
  • <5 µg/m²h for formaldehyde.

 

The interpretation of these results by BRE are if all the walls (less door and window) of the 30 m³ reference room described in BS EN 16515‑2017 (with a ventilation rate of 0.5 air changes per hour) were clad with the Yeoman Shield PVC-U Falmouth Wall & Door Protection Panels, the increase in TVOC in the room would

be <20 µg/m³ for TVOC and <10 µg/m³ for formaldehyde and these are deemed to be low.

 

BREEAM Hea 02 has limits of 300 µg/m³ for TVOC and 100 µg/m³ for formaldehyde, so the theoretical increases in TVOC and formaldehyde from using the PVC-U sheet are deemed as low.

Yeoman Shield Corner Protection Angles and Trims provide protection to vulnerable corners from impact damage caused by either vehicular or pedestrian traffic and are available in a range of sizes and materials. Corner Protection Angles and Trims are suitable for use in hospitals, supermarkets, nursing homes, schools, banks, airports, offices and any other areas which are subject to damage by impact or abrasion.

Consult manufacturer for fixing instructions.

Approvals:

Extruded Textured Material fire tested to:

  • B-s2,d0.
  • BS EN 13823:2010 + A1:2014.
  • BS EN ISO 11925 - 2: 2010.
  • BS EN 13501 - 1: 2007 + A1:2009.
  • BS 476: Part 7: 1997 - The surface spread of flame of products - Class 1Y.
  • BS 476: Part 6: 1989 + A1:2009- Fire propagation for products - Class 0 - As defined in the latest Building Regulations, Approved Document B (Fire Safety).

VOC Emissions

Yeoman Shield PVC-U Falmouth Wall & Door Protection panels have been tested for VOC to ISO 16000-10:2006 Indoor air - Part 10.

 The test showed the following results:

  •  <10 µg/m²h for TVOC.
  • <5 µg/m²h for formaldehyde.

 

The interpretation of these results by BRE are if all the walls (less door and window) of the 30 m³ reference room described in BS EN 16515‑2017 (with a ventilation rate of 0.5 air changes per hour) were clad with the Yeoman Shield PVC-U Falmouth Wall & Door Protection Panels, the increase in TVOC in the room would

be <20 µg/m³ for TVOC and <10 µg/m³ for formaldehyde and these are deemed to be low.

 

BREEAM Hea 02 has limits of 300 µg/m³ for TVOC and 100 µg/m³ for formaldehyde, so the theoretical increases in TVOC and formaldehyde from using the PVC-U sheet are deemed as low.

Product certifications
Digital objects
Color
Black, Blue, Brown, Cream, Green, Grey, Orange, Pink, Purple, Red, White, Yellow, Other
Black, Blue, Brown, Cream, Green, Grey, Orange, Pink, Purple, Red, White, Yellow, Other
Finish
Micro-textured, Smooth
Micro-textured, Smooth
Material
Stainless steel, PVC-U, Rubber
Stainless steel, PVC-U, Rubber
Shape
Other
Other
Length
2500 mm, 1250 mm
2500 mm, 1250 mm
Width
75 mm, 50 mm, 38 mm
75 mm, 50 mm, 38 mm
Height
Bespoke
Bespoke

Specification

Classification data
Material
Yeoman Shield extruded PVC-U, 3 mm thick.
Yeoman Shield extruded PVC-U, 2 mm thick.
Fire rating
To BS 476-7, Class 1 and BS 476-6: 1989 + A1:2009, Class 0.
To BS 476-7, Class 1 and BS 476-6: 1989 + A1:2009, Class 0.
Finish
-
-
Colour
-
-
Texture
Strippled.
Smooth.
Size
75 x 75 mm, 1.25 m long., 75 x 75 mm, 2.5 m long., 50 x 50 mm, 1.25 m long., 50 x 50 mm, 2.5 m long., 38 x 38 mm, 1.25 m long., 38 x 38 mm, 2.5 m long., Bespoke.
65 x 65 mm, 3.5 m long., 50 x 50 mm, 3.5 m long., 38 x 38 mm, 3.5 m long., 25 x 25 mm, 3.5 m long., 80 x 80 mm, 3.5 m long.
Fixing
To be supplied with double-sided adhesive tape attached., Not required.
To be supplied with double-sided adhesive tape attached., Not required.

Additional properties

Angle
90°., 135°., Bespoke.
Manufacturer's standard.

Sustainability data

Material
Stainless steel, PVC-U, Rubber
Stainless steel, PVC-U, Rubber