SPEEDLINE Twin Frame I Stud Partition Systems Utilising Siniat Board
SPEEDLINE Twin Frame I Stud Partition Systems Utilising Siniat Board
SPEEDLINE Twin Frame I Stud Partition Systems Utilising Siniat Board

Verified 10 months ago

Metsec (voestalpine Metsec)

Verified 10 months ago

Metsec (voestalpine Metsec)

Verified 10 months ago

Metsec (voestalpine Metsec)
Summary
Lightweight plasterboard partition system.
-
-
Application

Wall partitions.

-
-
Description

Lightweight, quick to construct, cost-effective, compact and able to achieve high levels of fire resistance and sound insulation. The non-load bearing high performance walls, constructed from plasterboard facings on metal studs, offer considerable advantages over traditional heavy masonry construction.


Features and benefits:

  • Acoustics up to 70 Rw dB with Ctr of -10.
  • Suitable for use with Code for Sustainable Homes or BREEAM.
  • Suitable for party wall construction with requirements of +3 to +8 dB DnT,w on ADE requirements of 45 DnT,w + Ctr.
  • Fire resistance up to 120 mins BS 476:Part 22.
  • Structural columns can be incorporated within the partition cavity due to unbraced twin frame design.


Structural performance:

  • Strength grade to BS 5234-2:1992 Annexes A-F.

Fire performance:

  • Fire resistance to BS 476:1987:Part 22.

Acoustic performance:

  • Calculated weighted sound reduction index (Rw) to BS EN ISO 10140-2: 2010.

Installing framing for partitions:

  • Partition height (maximum) calculated based on a limiting deflection of L/240 at 200 Pascals.
-
-
Product certifications
-
-
Length
Bespoke
-
-
Width
210 mm, 250 mm, 270 mm, 300 mm, 320 mm, 340 mm, 350 mm, 370 mm, 380 mm, 450 mm, 490 mm
-
-
Height
Bespoke
-
-

Specification

Classification data
Framing
Twin Speedline 'I' Stud, 50 mm.
-
-
Insulation
Acoustic partition roll, 50+50 mm.
-
-
Linings
-
-
-
Inner layers
Siniat GTEC dB Board, 15 mm.
-
-
Outer layers
Siniat GTEC dB Board, 15 mm.
-
-
Fasteners
Speedline Drywall Screws.
-
-
Joint treatment
Speedline Drywall Fibreglass Tape., Speedline Ready Mix Joint Compound., Speedline Corner Bead Tape.
-
-
System accessories
Speedline Fire Rated Acoustic Sealant., Speedline PB24 Partition Brace., Speedline FS24 Flat Bracing Strip., Speedline Service Support Plate., Speedline Putty Pads.
-
-

Additional properties

Fire resistance
To BS 476:1987:Part 22, 90/ 90 minutes (Integrity/ Insulation).
-
-
Partition height
-
-
-
Nominal thickness
200 mm.
-
-
Calculated weighted sound reduction index (Rw)
69 (-2;-8) Rw dB.
-
-
Centres
600 mm., 400 mm.
-
-
StrengthGrade
Severe duty.
-
-
Head/ Floor channel
Speedline Standard Track., Speedline 32 mm Leg Track., Speedline Deep Track., Speedline Extra Deep Track.
-
-
Standards
To BS 5234-2:1992 Annexes A-F, BS 476:1987:Part 22, BS EN ISO 10140-2: 2010.
-
-