NBS Source
I'm a manufacturer
Compare variants

12340 PD Panic Sashlock

Verified by manufacturer 3 months ago

DIN

Glutz UK Ltd Variant:

Mortice lock, panic D.

Jump to:
+44 (0)1376 348808 Website

Application

For use in commercial buildings, e.g. nursing homes, schools and sports halls.

Description

Mortice lock, panic D, for connecting or corridor doors. In daytime and night-time operation, the external lever handle can be coupled or decoupled via the cylinder by turning a key until it stops. When the panic function is activated from inside, the external lever handle is automatically coupled and access from the outside therefore becomes possible at any time (passage function).


Note: Thumbturn cylinders must not be used, with the exception of E-thumbturn cylinders with cam resetting. When using a standard cylinder, the key must always be removed. Lever handles must be fixed rotating on plates/ roses (easyfix®).


Features and benefits:

  • Mortice lock with panic D function.
  • Centred lock case with single-throw 20 mm deadbolt ejector.
  • By turning a key until it stops, the lock is locked/ unlocked and the external lever handle simultaneously coupled/ decoupled.
  • When locked, the external lever handle is decoupled if the panic function is activated, the external lever handle is automatically coupled.
  • Quiet closing due to the comfort latch with dampened latch throw.
  • Lever handle bearing with no backlash due to the two-part split clamp follower.
  • Linear lever handle operation and holding up torque.
  • Reversible due to the reversible DIN L/R latch.
  • Panic function reversible inwards/ outwards.
  • Follower turning angle 32°.

General information

Color

Silver

Finish

Matt

Material

Stainless steel

Length

230 mm

235 mm

Height

18 mm

20 mm

24 mm

Uniclass

Pr_30_36_08_24 Door latchesPrimary

CAWS

P21/24 Door locks

P21/515 Door locks

Specification data - Door latches

Standard

To EN 12209:2003+AC:2005, EN 1125 and EN 179.

Classification grades (minimum)

-

Category of use

Grade 3.

Durability

Grade M.

Door mass and closing force

Grade 5.

Suitability for use on fire-resisting and/ or smoke control doorset

Grade 1.

Safety

Grade 0.

Corrosion resistance and temperature

Grade F.

Security and drill resistance

Grade 4.

Key identification requirement

Grade 0.

Latch or lock type

Mortice lock.

Backset

55 mm.

65 mm.

80 mm.

Material and finish

Matt stainless steel faceplate.

Manufacturer guidance

Other finishes on request.

Cut-outs

RZ.

PZ.

Locks with follower

9 mm.

Forend

Radiussed, 20 x 235 mm.

Radiussed, 24 x 235 mm.