NBS Source
I'm a manufacturer

Bauderflex Warm Roof System - Self Adhered

Verified by manufacturer 1 year ago

Bauder Ltd Third party certifications:
  • EPD

    EPD

    Certificate type

  • BBA Agrément Certificate

    BBA Agrément Certificate

    Certificate type

  • CCPI System

    CCPI System

    Certificate type

Two-layer, self adhered, warm roof, bitumen membrane waterproofing system suitable for new build and refurbishment applications.

Jump to:
BOS
+44 (0)1473 257671 Website

Application

Suitable for new build and refurbishment applications and can be used in warm, cold and inverted roof scenarios, including green roof applications.

Description

Bitumen warm roof system, incorporating torch-on bitumen capping sheet with self-adhered bitumen underlayer, insulation and self-adhered bitumen air and vapour control layer (AVCL).

Bauderflex Roof System is suitable for a variety of applications on both new build and refurbishment projects and can be used in warm, cold and inverted roof scenarios. Includes the option of using a root resistant cap sheet, making this waterproofing system suitable for green roof situations.

See BBA certification 10/4744. Bauderflex can meet current UK Building Regulations Part B for external fire protection, and can feature torch-free and safe to torch installation on combustible details.


Features and benefits:

  • Capping sheets with tensile strength up to 800 N/50mm.
  • Withstands climatic extremes of over 100⁰C variation.
  • Patented self-adhesive DUO products. The "DUO" lap technology ensures thorough sealing of lap joints, even in lower temperatures.
  • Expandable graphite fire retardant prevents spread of flame.
  • Heavy duty, robust and extremely tough.
  • Service life in excess of 30 years as stated in BBA certificate 10/4744.
  • Resistant to European climatic conditions.
  • Membrane resists impact and tearing.
  • Can satisfy requirements of Part B of Building Regulations.


Torch-Free/ Safe to Torch Zone Detailing:

Bauder was the first manufacturer to pledge its support to the Safe2Torch initiative, introduced by the National Federation of Roof Contractors (NRFC) in July 2017. The torch-free detailing designs specifically deliver secure and safe installations in the vicinity of combustible construction materials located on, or connected to, the roof such as timber substrates or upstands; abutments to cladding, roof tiles, slates or thatch; or debris such as dry leaf material that is at risk from ignition.

Torch-free detailing can be integrated into all bituminous waterproofing solutions to give versatile, safe installation techniques for all roof types, site conditions and budgets.

The waterproofing flashing should be turned up by at least 150 mm around features such as rooflights, parapets and service pipes passing through the roof, detail work to upstands, edge details, flashings, etc. The membrane should not be taken up in one piece. Consult manufacturer for further information.


Features and benefits of Torch-Free/ Safe to Torch Zone Detailing:

  • Complete range of self-adhesive bitumen membranes.
  • Installation follows industry best practice and conforms to BS 8217: 2005.
  • 4.2 mm-thick elastomeric KSO SN, KSO ALP SN and KSO P-SN cap sheets.
  • Hot air welding of membrane laps in the torch-free zone.
  • Bauder polyisocyanurate (PIR) insulation bonded with polyurethane (PUR) adhesive in warm roof construction.
  • Can comply with Building Regulations Approved Document B – Fire Safety.
  • Manufactured to BS EN 13707: 2004 Reinforced Bitumen Membrane Sheets.
  • Reduces risk of fire caused by installation.
  • Practical solution so that installation programme times are achievable.
  • Robust waterproofing without compromising system longevity.

General information

Color

Black

Finish

Mineral

Material

Bitumen

Shape

Square

Rectangle

Warranty description

-

Manufacturer guidance

Guarantee options could include ‘Product’, ‘Product and Workmanship’ and ‘Product, Workmanship and Design’ Guarantees. All guarantees available for this system are subject to the works being carried out in accordance with the Bauder specification and being installed by a Bauder Approved installer. For full details and further information regarding guarantees and alternative systems, consult manufacturer.

Uniclass

Ss_30_40_30_72 Reinforced bitumen membrane warm roof covering systemsPrimary

CAWS

J41/10 Reinforced bitumen membrane warm deck roof covering

J41/110 Built-up reinforced bitumen membrane warm deck roof covering

Product range

Built-Up Bituminous Systems

Specification data - Reinforced bitumen membrane warm roof covering systems

Preparation

-

Horizontal work

Bauder Activator-Primer (Canister) APR01.

Guidance for specification option:

Synthetic rubber resin-based primer, developed to provide the necessary preparation of substrates prior to the installation of self-adhesive and torch-applied membranes. The spray application offers improved film thickness speed of application (by up to 50% over roller applied products) and quick drying in a matter of minutes.

  • Coverage: Approximately 96 g/m² (300 mm wide spray one coat, 192 g/m² two coats). Two coats may be required for very porous substrates.
  • Application temperature: +5 to +30°C.
  • Drying time (at 10°C): 5–10 minutes.
  • Colour: Black.
  • Recoat time if left exposed: Four hours.
  • Suitable substrates: Oriented strand board (OSB); plywood; timber; concrete; lightweight concrete or cementitious materials; metal; Bauder self-adhesive underlayers; existing asphalt and bitumen membranes; polyisocyanurate (PIR) insulation.

Non-suitable substrates: Mica finished surfaces (e.g. KSD FBS); Laminated paper-foil faced insulation; expanded polystyrene (EPS) or extruded polystyrene (XPS) insulations; BauderROCK or mineral wool insulation; BauderGLAS or cellular glass insulation; copper; thermoplastic waterproofing membranes.

Skirtings and vertical work

As 'Horizontal work'.

Air and vapour control layer

-

Type

KSD FBS.

Guidance for specification option:

Robust, self-adhesive elastomeric bitumen air and vapour control layer (AVCL), with a mica finished upper surface to allow easy bonding of insulation using appropriate Bauder Insulation Adhesive. One side lap features an 80 mm wide glass fleece along the underside, and a 100 mm strip of aluminium foil above. The other side lap has a thermofusible film on the top surface. This arrangement ensures that laps are heat sealed using hot air or gas torch as appropriate to extrude a bitumen bead, thus ensuring waterproofing integrity.

  • Width: 1.08 m.
  • Length: 10 m.
  • Thickness: 2.5 mm.
  • Weight: 2.5 kg/m².
  • Reinforcement: Polyester coated aluminium foil and 200 g/m² glass fleece.
  • Tensile strength: Length and Diagonal ≥ 1000 N/50mm.
  • Cold bending test: -25°C.
  • Elongation at break: Length and Diagonal ≥ 2%.


DS1 DUO.

Guidance for specification option:

Self-adhesive elastomeric bitumen air and vapour control layer with patented “DUO” lap technology to ensure thorough sealing of lap joints, even in lower temperatures. The product also features thermally activated bitumen stripes on its top surface to provide the bonding compound for the insulation boards. Allows for cleaner, safer and faster installation than traditional torch applied membranes.

  • Width: 1.08 m.
  • Length: 7.5 m.
  • Thickness: 3.5 mm.
  • Weight: 4.5 kg/m².
  • Reinforcement: Polyester coated aluminium foil and 60 g/m² glass fleece.
  • Tensile strength: Length ≥400 N/50mm and Diagonal ≥ 300 N/50mm.
  • Cold bending test: -25°C.
  • Elongation at break: Length and Diagonal ≥ 2%.

Attachment

Self adhesive.

Insulation

-

Type

BauderGLAS Flatboard.

Guidance for specification option:

Insert required thickness.


Can only be used with PU Insulation Adhesive – Tin (with ‘water-overmist’) or PU Insulation Adhesive – Twin cartridge.


Cellular glass insulation suitable for projects that require a high level of compressive strength and/ or to be non-combustible.


  • Type: Cellular glass flatboard insulation board.
  • Facing: Glass tissue or none faced (depending upon system).
  • Density: 100 kg/m³.
  • Board size: Contact manufacturer for options.
  • Thickness (Flatboard): 50 mm, 60 mm, 70 mm, 80 mm, 90 mm, 100 mm, 110 mm, 120 mm, 130 mm, 140 mm, 150 mm, 170 mm, 180 mm (also available in Tapered).
  • Thermal conductivity: 0.036 W/m·K (may vary dependent on thickness specified).
  • Compressive strength: 0.5 N/mm².


BauderGLAS Tapered.

Guidance for specification option:

Insert required thickness.


Can only be used with PU Insulation Adhesive – Tin (with ‘water-overmist’) or PU Insulation Adhesive – Twin cartridge.


Cellular glass insulation suitable for projects that require a high level of compressive strength and/ or to be non-combustible.

  • Type: Cellular glass tapered insulation board.
  • Facing: Glass tissue or none faced (depending upon system).
  • Density: 100 kg/m³.
  • Board size: Contact manufacturer for options.
  • Thickness (Tapered): 50 mm, 60 mm, 70 mm, 80 mm, 90 mm, 100 mm, 110 mm, 120 mm, 130 mm, 140 mm, 150 mm, 170 mm, 180 mm.
  • Thermal conductivity: 0.036 W/m·K (may vary dependent on thickness specified).
  • Compressive strength: 0.5 N/mm².


BauderROCK Flatboard.

Guidance for specification option:

Insert required thickness.


Can only be used with PU Insulation Adhesive – Tin (with ‘water-overmist’) or PU Insulation Adhesive – Twin cartridge or mechanically fixed.


Mineral fibre insulation suitable for projects that require a high level of sound reduction and/ or to be non-combustible, and has a zero GWP and ODP rating.

  • Type: Dual density mineral wool flatboard insulation board.
  • Facing: Top: 300 g/m² glass fibre fleece; Bottom: Unfaced.
  • Density: 160 kg/m³.
  • Board size: 1200 x 1000 mm.
  • Board thickness (Flatboard): 60 mm, 85 mm, 105 mm, 115 mm, 150 mm, 170 mm, 185 mm (also available in Tapered).
  • Thermal conductivity: 0.039 W/m·K (may vary dependent on thickness specified).
  • Compressive strength: >0.12 N/mm² (minimum 0.08 N/mm²).


BauderROCK Tapered.

Guidance for specification option:

Insert required thickness.


Can only be used with PU Insulation Adhesive – Tin (with ‘water-overmist’) or PU Insulation Adhesive – Twin cartridge or mechanically fixed.


Mineral fibre insulation suitable for projects that require a high level of sound reduction and/ or to be non-combustible, and has a zero GWP and ODP rating.

  • Type: Dual density mineral wool tapered insulation board.
  • Facing: Top: 300 g/m² glass fibre fleece; Bottom: Unfaced.
  • Density: 160 kg/m³.
  • Board size: 1200 x 1000 mm.
  • Board thickness (Tapered): 60 mm, 85 mm, 105 mm, 115 mm, 150 mm, 170 mm, 185 mm.
  • Thermal conductivity: 0.039 W/m·K (may vary dependent on thickness specified).
  • Compressive strength: >0.12 N/mm² (minimum 0.08 N/mm²).


BauderVIP TE 60 mm Flatboard.

Guidance for specification option:

  • Type: Vacuum insulation panel with pyrogenic silica vacuum core, 40 mm.
  • Facing: Top: High density PIR, 17 mm; Bottom: Rubber granulate, 3 mm.
  • Density: 13 kg/m².
  • Standard board sizes: 1000 x 1000 mm and 1000 x 500 mm.
  • Standard board thickness: 60 mm.
  • Thermal conductivity: 0.009 W/m·K.


BauderVIP TE 80 mm Flatboard.

Guidance for specification option:

  • Type: Vacuum insulation panel with pyrogenic silica vacuum core, 60 mm.
  • Facing: Top: High density PIR, 17 mm; Bottom: Rubber granulate, 3 mm.
  • Density: 17 kg/m².
  • Board sizes: 1000 x 1000 mm, 1000 x 500 mm.
  • Board thickness: 80 mm.
  • Thermal Conductivity: 0.009 W/m·K.
  • Compressive strength: >0.12 N/mm².


PIR FA G16 foil-faced tapered insulation.

Guidance for specification option:

Insert required thickness.


  • Type: Rigid closed-cell polyisocyanurate (PIR) roofboard: To BS EN 13165.
  • Facing: Black aluminium foil to both faces.
  • Density: >30 kg/m³.
  • Standard board size: 1200 x 1200 mm.
  • Board thickness: Contact manufacturer for options.
  • Thermal conductivity: 0.022 W/m·K (may vary dependent on thickness specified).
  • Compressive strength: >0.12 N/mm².
  • PIR index: >250 (extremely high dimensional stability).


PIR FA-TE Flatboard.

Guidance for specification option:

Insert required thickness.


  • Type: Rigid closed-cell polyisocyanurate (PIR) roofboard: To BS EN 13165.
  • Facing: Aluminium foil to both faces.
  • Density: >30 kg/m³.
  • Standard board size: 1200 x 600 mm.
  • Board thickness: 30 mm, 40 mm, 50 mm, 60 mm, 80 mm, 100 mm, 120 mm, 140 mm, 160 mm.
  • Thermal conductivity: 0.022 W/m·K (may vary dependent on thickness specified).
  • Compressive strength: >0.12 N/mm².
  • PIR index: >250 (extremely high dimensional stability).

Fixing

PU Insulation Adhesive – Tin.

Guidance for specification option:

Not for foil to foil applications (e.g. FA-TE to FA-TE).

Activator-Primer (Canister) APR01 – Black.

PU Insulation Adhesive – Twin cartridge.

Waterproof covering

-

First layer

-

Type

BauderTEC Sprint DUO.

Guidance for specification option:

Peel off release film, foil faced, 2 mm thick.

Attachment

Self-adhesive.

Top layer

-

Type

PYE PV 200 S4.

Guidance for specification option:

High performance, elastomeric bitumen, mica finished capping sheet, 4.2 mm thick. No UV protection, only suitable for applications where it is totally covered; not for exposed roofs.


  • Width: 1 m.
  • Length: 10 m.
  • Thickness: 4.2 mm.
  • Weight: 5 kg/m².
  • Surface: Top: Mica; Bottom: Thermofusible polyethylene.
  • Reinforcement: 250 g/m² recycled spunbond polyester.
  • Cold bending test: -25°C.
  • Softening point: >100°C.
  • Tensile strength: Length >800 N/50mm; transverse >800 N/50mm.
  • Elongation at break: Length >35%; transverse >35%.


Bauder K4E Capping Sheet, Brown.

Guidance for specification option:

High performance, elastomeric bitumen, mineral finished, capping sheet, 4.2 mm thick.


Expandable graphite fire retardant is also incorporated to reduce spread of flame.

  • Width: 1 m.
  • Length: 7.5 m.
  • Thickness: 4.2 mm.
  • Weight: 5.5 kg/m² (Charcoal Grey); 5 kg/m² (Grey Slate, Brown).
  • Surface: Top mineral chippings.
  • Bottom: Thermofusible polyethylene.
  • Reinforcement: 250 g/m² spunbound polyester.
  • Cold bending test: -30°C.
  • Softening point: >110°C.
  • Tensile strength: length >800 N/50mm; transverse >800 N/50mm.
  • Elongation at break: length >40%; transverse >40%.


Bauder K4E Capping Sheet, Charcoal Grey.

Guidance for specification option:

High performance, elastomeric bitumen, mineral finished, capping sheet, 4.2 mm thick.


Expandable graphite fire retardant is also incorporated to reduce spread of flame.

  • Width: 1 m.
  • Length: 7.5 m.
  • Thickness: 4.2 mm.
  • Weight: 5.5 kg/m² (Charcoal Grey); 5 kg/m² (Grey Slate, Brown).
  • Surface: Top mineral chippings.
  • Bottom: Thermofusible polyethylene.
  • Reinforcement: 250 g/m² spunbound polyester.
  • Cold bending test: -30°C.
  • Softening point: >110°C.
  • Tensile strength: length >800 N/50mm; transverse >800 N/50mm.
  • Elongation at break: length >40%; transverse >40%.


Bauder K4E Capping Sheet, Grey Slate.

Guidance for specification option:

High performance, elastomeric bitumen, mineral finished, capping sheet, 4.2 mm thick.


Expandable graphite fire retardant is also incorporated to reduce spread of flame.

  • Width: 1 m.
  • Length: 7.5 m.
  • Thickness: 4.2 mm.
  • Weight: 5.5 kg/m² (Charcoal Grey); 5 kg/m² (Grey Slate, Brown).
  • Surface: Top mineral chippings.
  • Bottom: Thermofusible polyethylene.
  • Reinforcement: 250 g/m² spunbound polyester.
  • Cold bending test: -30°C.
  • Softening point: >110°C.
  • Tensile strength: length >800 N/50mm; transverse >800 N/50mm.
  • Elongation at break: length >40%; transverse >40%.

Manufacturer guidance

Not for use with green roof systems.

Attachment

Torch applied.

Detail work

-

Flashings

Not required.

Bauder GRP Trim.

Guidance for specification option:

GRP roof edge Trim for use with Bauder bituminous roof systems. Available colours of either grey or black and a choice of profiles to suit the requirements of most projects.

Bauder Aluminium Termination Bar.

Guidance for specification option:

Natural finish aluminium alternative to a lead counterflashing for use at upstand details to give protection to the top edge of the waterproofing. It should be restricted to use on upstands where a chase cannot be cut into the wall.

Bauder GRP Termination Bar.

Guidance for specification option:

Black glass reinforced plastic (GRP) alternative to a lead counterflashing for use at upstand details to give protection to the top edge of the waterproofing. It should be restricted to use on upstands where a chase cannot be cut into the wall.

Skirtings and upstands

Not required.

Bauder LiquiFIBRE Detailing Kit.

Guidance for specification option:

Fast curing waterproofing resin containing fibre reinforcement that can be used for detailing awkward shapes or inaccessible areas where using LiquiDETAIL is impractical. PMMA-based resin that requires a catalyst and is solvent, isocyanate and halogen free.

Bauder LiquiDETAIL.

Guidance for specification option:

Cold liquid applied fast curing waterproofing resin that can be used on upstands and details. PMMA-based resin that requires the addition of catalyst to trigger curing and is solvent, isocyanate and halogen free.

Welted drips

Required.

Guidance for specification option:

Insert requirement.

Not required.

Cover strips

Required.

Guidance for specification option:

Insert requirement.

Not required.

Ancillary items

Required.

Guidance for specification option:

Insert requirement.

Not required.

System accessories

Not required.

Bauder lightning conductors.

Guidance for specification option:

Lightning conductor clips are a specially designed secure clip that allows for movement.

Type 4: Polyvinyl chloride (PVC) coated or bare conductor.

Bauder insulated rainwater outlets.

Guidance for specification option:

Consult manufacturer for details.

BauderSOLAR F Photovoltaic Mounting System.

Guidance for specification option:

Consult manufacturer for details.

Bauder Rooflights and Opening Vents.

Guidance for specification option:

Consult manufacturer for details.

Sustainability data

Third party certifications

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
Revit
-

4

IFC
-

1

Third party certifications

EPD

EPD

Environmental Product Declaration - RBM

BBA Agrément Certificate

BBA Agrément Certificate

Certificate: Bauderflex Systems 10/4744

CCPI System

CCPI System

Bauder Bauderflex-BauderflexGreen-CCPI

Similar products from Bauder Ltd

Bauder System Airtech Warm Roof System - Self Adhered

Bauder System Airtech Warm Roof System - Self Adhered

Bauder Total Green Roof System PLUS Reinforced Bitumen Membrane Warm Roof Covering System Self-Adhered (with Torch-On Capping Sheet)

Bauder Total Green Roof System PLUS Reinforced Bitumen Membrane Warm Roof Covering System Self-Adhered (with Torch-On Capping Sheet)

Bauder Total Green Roof System Reinforced Bitumen Membrane Warm Roof Covering System - Torch Applied.

Bauder Total Green Roof System Reinforced Bitumen Membrane Warm Roof Covering System - Torch Applied.

Bauder Total Green Roof System Reinforced Bitumen Membrane Warm Roof Covering System Self-Adhered (with Torch-On Capping Sheet)

Bauder Total Green Roof System Reinforced Bitumen Membrane Warm Roof Covering System Self-Adhered (with Torch-On Capping Sheet)

Bauder Total Warm Roof System - Self Adhered

Bauder Total Warm Roof System - Self Adhered

Bauder Total Warm Roof System - Torch Applied

Bauder Total Warm Roof System - Torch Applied

Bauder Total Warm Roof System PLUS - Self Adhered

Bauder Total Warm Roof System PLUS - Self Adhered

Bauderflex Green Warm Roof System - Self Adhered (with Torch-On Capping Sheet)

Bauderflex Green Warm Roof System - Self Adhered (with Torch-On Capping Sheet)

Bauderflex Warm Roof System - Torch Applied

Bauderflex Warm Roof System - Torch Applied