Mechanically fixed brick slip system.

Jump to:
Request BIM
01483 898125 Website

Application

Mechanically fixed brick slip system suitable for new build, retrofit and recladding projects.

It can be applied to various substrates:

  • SFS.
  • Concrete frame.
  • Brickwork.
  • blockwork
  • Timber frame.
  • Insulated carrier panels.
  • Existing buildings.

The system can incorporate insulation to upgrade the thermal performance of existing building and meet U-value targets for new build designs.

  • High rise applications.
  • Low rise applications.
  • Mixed use developments.
  • Data centers.
  • Warehousing.
  • Industrial.
  • Commercial.

Description

Briklok™ is a drained and ventilated cladding system that combines traditional brick detailing and modern construction techniques.

Use with natural clay brick slips to create the warmth and texture of a traditional brick façade

The system uses a kerf design to mechanically fix the slips to the Briklok™ profiles. No resins or adhesives are used to secure the brick slips.

Features and benefits:

  • RJ Facades partner with Ibstock Futures to fabricate Ibstock bricks and 3rd party bricks into Briklok™ slips.
  • Slips are cut from a natural brick, with no bonded corners.
  • Complex detailing made simple. Projecting bricks, corduroy effects are easily integrated.
  • Adjustable to meet site tolerances +/-1 mm per brick course.
  • Off-site prefabrication of column / pier details - increasing accuracy and reducing installation time.
  • Designed for simple cavity barrier installation. The Briklok™ interlocking rail system provides a continuous aluminium backing surface facing into the rainscreen cavity. This gives a solid and continuous surface to compress the vertical cavity barrier against.
  • Briklok™ system has been tested to TGD19 in conjunction with FSi Horizontal Ventilated Cavity Barriers rated at E90 I30, and achieved a combined rating of E90 I30
  • When tested to BS EN 13501-1, the components and the system achieved Euroclass A1
  • Made in UK using low carbon Hydro 4.0 Anodized aluminium - the lowest available in the UK.

General information

Color

Silver

Other

Finish

Anodized

Material

Aluminium

Stainless steel

Brick

Shape

Other

Length

Bespoke

Width

Bespoke

Manufacturer guidance

Minimum 62 mm.

Maximum 67 mm.

Height

Bespoke

Warranty description

25 year

Uniclass

Ss_25_20_70_25 Drained and back-ventilated rainscreen cladding systemsPrimary

CAWS

F10/110 Clay facing brickwork

F10/5 Facing brickwork

H92/120 Rainscreen cladding

Specification data - Drained and back-ventilated rainscreen cladding systems

Classification data

Thermal insulation

Mineral wool slab insulation.

Guidance for specification option:

Recommended Insulation Type. Insert requirements or omit.

Mineral fibre slab insulation.

Guidance for specification option:

Insert requirements or omit.

Phenolic foam boards.

Guidance for specification option:

Insert requirements or omit.

Polyisocyanurate (PIR) foam boards.

Guidance for specification option:

Insert requirements or omit.

Polyurethane (PUR) foam boards.

Guidance for specification option:

Insert requirements or omit.

Manufacturer guidance

Please consult RJ Facades with required U-value and they will calculate using three-dimensional analysis. Insert requirements.

Breather membrane

-

Material

-

Manufacturer guidance

Required. Vapour-permeable sheets not provided. Please consult RJ Facades for guidance and best practice recommendations. Insert requirements.

Fasteners

Stainless steel nails.
Carbon steel wire nails.
Staples.

Manufacturer guidance

Dependant on chosen breather membrane. Consult breather membrane manufacturer and insert requirements or omit.

Secondary support structure

T-profile.
L-profile.
Structural top hats.
Structural C-profiles.

Cavity fire barriers

-

Horizontal

-

Manufacturer guidance

Briklok system has been tested to TGD-019 in conjunction with cavity barrier system FSi Silverliner OSCB1 Horizontal Ventilated Cavity Barriers rated E90 I30, achieved a combined rating of E90 I30, unaffecting the performance of the barrier.

Consult manufacturer and insert requirements or omit.

Vertical

-

Manufacturer guidance

The briklok interlocking rail system provides a continuous aluminium backing surface facing into the rainscreen cavity. This gives a solid and continuous surface to compress vertical cavity barrier against.

Consult manufacturer and insert requirements or omit.

Cladding panels

-

Material

Clay brick slips.

Panel joints

Closed joints.
Sealed joints.

Reveals

-

Manufacturer guidance

Reveals are accommodated as part of the system. Please consult RJ Facades for further details and insert requirements.

System accessories

Insect guard mesh.
Metal drip trims.
Metal finishing trims.
Silicone construction joint sealants.

Manufacturer guidance

Consult RJ Facades for further details and insert requirements.

Material grade

Anodized Aluminium EN AW-6063 T6.

Brackets

EVT II L-brackets - aluminium.
EVT II L-brackets - stainless steel.
EVT II U-brackets - aluminium.
EVT II U-brackets - stainless steel.

Manufacturer guidance

Available in a range of sizes. Consult manufacturer for further details and insert requirements.

Fixings

Stainless steel.

Guidance for specification option:

Consult manufacturer and insert requirements.

Secondary fixings

-

Manufacturer guidance

Consult manufacturer and insert requirements or omit.

Standards

To BS EN 771-1.

Guidance for specification option:

(Brick slip design only).

Certification

UKAS/ UL Winmark approval/ CWCT (sequence B).

Sustainability data

Country of product manufacture

United Kingdom

Material

Aluminium
Stainless steel
Brick
Carbon dioxide equivalent

Carbon dioxide equivalent, as defined in BS EN 15804

Certified

Stage
Normalised unit (kg CO₂ eq/kg)
Declared unit (kg CO₂ eq/unit)
Stage:A1–A3 ('Production stage')
Normalised unit :
Declared unit : 4.0

Recyclability

100% Recyclable

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

44 %

Expected Life

60 year

Product certifications

Product certifications

UKAS

UKAS

Briklok UKAS UL International Product Certification

CWCT Certificate

CWCT Certificate

Briklok CWCT Report (sequence B)

REACTION TO FIRE - CLASSIFICATION REPORT EUI-22-000041

REACTION TO FIRE - CLASSIFICATION REPORT EUI-22-000041

Briklok Warringtonfire A1 Fire Classification

UKAS

UKAS

RJ Facades UL UKAS R40530 Rev 7

EPD

EPD

RJ Facades EPD - Briklok

Literature

Briklok™ Brick Slip

Briklok™ Brick Slip