Verified by manufacturer 24 days ago
CU2-L500 fire damper
DoP
Certificate type
UK Conformity Assessed (UKCA)
Certificate type
Hygiene requirements to VDI 6022
Certificate type
Classification report acc. to EN 13501-3
Certificate type
Rectangular EIS fire damper for duct sizes up to W1500 x H1000 mm, with a fire resistance up to 120 minutes, for motorized and non-motorized applications. (previously known as FD or FSD / MFSD)
Rectangular EIS fire damper for duct sizes up to W1500 x H1000 mm, with a fire resistance up to 120 minutes, for motorized and non-motorized applications.
(previously known as FD or FSD / MFSD)
CU2 Certified installations and sealing methods
CU2 Fields of application:
CU2 Building applications:
Rectangular EIS fire damper for duct sizes up to W1500 x H1000 mm, with a fire resistance up to 120 minutes, for motorized and non-motorized applications.
(previously known as FD or FSD / MFSD)
CU2 Distinct Product Features (incl. specifications)
CU2 User benefits:
CU2 Range:
CU2 Configurations & options:
Notes:
Color | White |
Material | Calcium silicate |
Shape | Rectangle Square |
Length | 400 mm Guidance for specification option: Casing depth, standard CU2 model. 500 mm Guidance for specification option: Casing depth, CU2-L500 model. Bespoke Guidance for specification option: Casing depth, extended to prevent the damper blade from exceeding the damper casing, CU2L model. |
Width | 200 mm 250 mm 300 mm 350 mm 400 mm |
Height | 200 mm 250 mm 300 mm 350 mm 400 mm |
Warranty description | One year |
Uniclass | |
CAWS | U90/443 Dampers, fire/ smoke |
Standard | |
Fire dampers | To EN 15650:2010. |
Test | To EN 1366-2, up to 500 Pa. |
Classification | To EN 13501-3. |
Arrangement | Single-blade. |
Classification | Guidance for specification option: To EN 13501-3, up to EI 120 (ve ho i <-> o) S - (500 Pa) depending on installation method; consult manufacturer and insert details. |
Material | Tunnel casing: Calcium silicate.Guidance for specification option: Consult manufacturer for details of other components. |
Accessories | UL inspection shutter.Guidance for specification option: Set of two. EQ equipotential connection.PG20 connection to ducts with 20 mm flanges.Guidance for specification option: Note: This supersedes the standard PG30 connection and cannot be combined with the PG40, PM or PP options. PG40 connection to ducts with 40 mm flanges.Guidance for specification option: Note: This supersedes the standard PG30 connection and cannot be combined with the PG20, PM or PP options. PM connection to ducts by insertion.Guidance for specification option: Note: This supersedes the standard PG30 connection and cannot be combined with the PG20, PG40 or PP options. This type of connection is used in case of lack of space for a standard PG30 frame. PP flange - no connection.Guidance for specification option: This type of frame is used on one side of a fire damper that ends into a room. Possible on mechanism side instead of PG30 connection (at order time). Note: This supersedes the standard PG30 connection and cannot be combined with the PG20, PG40 or PM options. None. |
Fusible links | |
Fusing temperature | 72°C. |
Dimensions | Guidance for specification option: Consult manufacturer's literature for performance details and insert requirements:
Standard units weigh 9.8–85.3 kg dependent on size required; consult manufacturer's literature for details. Intermediate dimensions available on request. Note that heights ≥275 and ≤299 mm are not available. |
Pressure loss | Guidance for specification option: Insert details, dependent on required damper size and air flow/air speed; consult manufacturer's technical literature for details. |
Air tightness | Class B. Class C. Guidance for specification option: Air-tightness class C against EN 1751 (for W >800, or H >600 mm) (option EN1751_C). Manufacturer guidanceTo EN 1751. |
Thermal release mechanism | Actuator - ONE T 24 V. Actuator - ONE T 230 V. Actuator - ONE-X 24 V. Guidance for specification option: Motor with an integrated control module, used in combination with the ZENiX controls solution by Rf-Technologies. Actuator - ONE-X 230 V. Guidance for specification option: Motor with an integrated control module, used in combination with the ZENiX controls solution by Rf-Technologies. Actuator - Belimo 24 V. |
Integral accessories | PG30 connection to ducts with 30 mm flanges. Guidance for specification option: Tunnel casing extension:
|
Third-party certification | UKCA marked 2822-UKCA-CPR-0057. |
Country of material origin | Europe |
Country of product manufacture | Belgium |
CR120 - Circular EIS Fire Damper (max Ø 315mm) - Fire Damper
CR2 - Circular EIS Fire Damper (max Ø 630mm) - Fire Damper
CR60 - Circular EIS Fire Damper (max Ø 315mm) - Fire Damper
CR60-1S - "ZERO liabilities" - EIS Circular Fire Damper (max Ø 315mm) - Fire Damper
CU-LT - Rectangular EIS Fire Damper (max W800 x H600 mm) - Fire Damper
CU2/B - Large Rectangular EIS Fire Damper - Maximum Four Individual Fire Dampers
CU4 - Rectangular EIS 4Hours Fire Damper - Fire Damper