Verified by manufacturer 8 months ago
Suspended ceiling system with lay-in mineral ceiling tiles with a special polyester membrane finish providing high ISO clean room performance.
Suitable for computer rooms and clean room environments.
Suspended ceiling system with lay-in mineral ceiling tiles with a special polyester membrane finish providing high ISO clean room performance.
Features and benefits:
Color | White |
Finish | Coated |
Material | Mineral Steel |
Shape | Square Rectangle Other |
Warranty description | 15 year Guidance for specification option: Product guarantee. 30 year Guidance for specification option: System guarantee. |
Uniclass | |
CAWS | K40/10 Unit/ modular suspended ceilings K40/105 Suspended ceiling system K40/115 Unit/ modular suspended ceiling system |
Product range |
System performance | Guidance for specification option: Insert requirements. |
Ceiling support | Gridline 24 joggled/butt cut, Global White.Guidance for specification option: Gridline 24 Cross Tees are designed to work with Gridline 24, a 24 mm exposed grid system for suspended ceilings. These cross tees come with standard SureLock clip for secure connections to main runners, providing better alignment for easier ceiling installation and easy disconnection when access to the ceiling soffit is required. Baked polyester paint finish. Gridline 24 joggled/butt cut, Black.Guidance for specification option: Gridline 24 Cross Tees are designed to work with Gridline 24, a 24 mm exposed grid system for suspended ceilings. These cross tees come with standard SureLock clip for secure connections to main runners, providing better alignment for easier ceiling installation and easy disconnection when access to the ceiling soffit is required. Baked polyester paint finish. Gridline 24 Corrosive Resistant, Global White.Guidance for specification option: Consult manufacturer for options and insert requirements. Corrosive Resistant TL+ Cross Tees are finished with a special corrosion resistant paint for better performance in high humidity environments - recommended when system is to be installed in areas >90% relative humidity. These cross tees are Durability Class C (EN 13964:2004 + A1:2006) and have completed a 700 hours salt spray test (EN ISO 9227). Clean Room 24, Global White.Guidance for specification option: Exposed 24 mm co-extruded grid system for clean rooms and non-magnetic areas. They can be used in clean rooms with ISO 4 classification in accordance with ISO 14644-1:1999. |
Support fasteners | Guidance for specification option: Insert requirements to suit substrate. |
Ceiling units | 600 x 600 x 15 mm, board edge, Global White.1200 x 600 x 15 mm, board edge, Global White.Manufacturer guidance
|
Barriers in ceiling void | |
Fire barriers | Guidance for specification option: Consult manufacturer for options and insert requirements, or omit. |
Acoustic barriers | Guidance for specification option: Consult manufacturer for options and insert requirements, or omit. |
Plenum barriers | Guidance for specification option: Consult manufacturer for options and insert requirements, or omit. |
System accessories | Guidance for specification option: Consult manufacturer for options and insert requirements, or omit. |
Weight | Infill units: 5.3 kg/m². |
ThermalConductivity | Infill units: 0.06 W/m·K. |
Reaction to fire | To EN 13501-1, infill units: Euroclass A2-s1, d0; support grid: Euroclass A1. |
Sound absorption | Infill units: αw = 0.15; Class E. Manufacturer guidanceWeighted sound absorption coefficient (alpha w). Rating for random incidence sound absorption determined in accordance with EN ISO 11654. Measured values obtained in accordance with EN ISO 20354 are converted into octave bands, plotted on a graph and compared to a standard reference curve until a 'best fit' is obtained. The derived αw will vary between 0.00 and 1.00. |
Sound attenuation | Infill units: Dnfw = 36 dB. Manufacturer guidanceDnfw rating derived from laboratory measurement of room-to-room airborne sound insulation of suspended ceiling with plenum above. Rating determined in accordance with EN ISO 717-1 from measurements made in accordance with ENIS0 10848-2 over the third-octave band frequency range 100–3150 Hz. |
Noise reduction coefficient | Infill units: 0.10. |
Formaldehyde emissions | Infill units: To EN 13964, formaldehyde emission level E1 = Best test result possible. |
Colour (Light reflectance value (LRV) | Infill units: 78%. |
Cleanroom classification | To ISO 14644-1: ISO 5. |
Material | Mineral Steel |
Recyclability | 100% |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 39 % |