NBS Source
I'm a manufacturer
Compare variants

Enclosed Automatic Transfer Switches (ATS) - Automatic Transfer Switching Equipment

Verified by manufacturer 6 days ago

Enclosed ATS, no bypass

ABB Ltd Variant:

Range of enclosed automatic transfer switches with bypass options.

Jump to:
+44 (0)24 7636 8500 Website

Application

Automatic transfer switching equipment.

Description

Range of enclosed automatic transfer switches with bypass options.


Features and benefits:

  • Available with single bypass, dual bypass, overlapping neutral (single/ dual bypass) or no bypass.
  • Easy to install.
  • Safety and protection: reduces risk of operator injury.
  • Optimum interface: simplifies connectivity.
  • TruONE® automatic commissioning capabilities.
  • Continuous operation.
  • Energy efficiency.
  • Optimized logistics.
  • Space saving.
  • Steel enclosures IP41 or IP54 options
  • Stainless Steel enclosures options for outdoor use IP65
  • Mimic and Fire Fighters Panels Available

General information

Color

Grey

Finish

Painted

Material

Steel

Guidance for specification option:

Enclosure.

Shape

Rectangle

Square

Length

250 mm

300 mm

400 mm

500 mm

600 mm

Width

600 mm

800 mm

1000 mm

1200 mm

Height

600 mm

800 mm

1000 mm

1200 mm

1400 mm

Show more

Uniclass

Pr_60_70_48_88 Transfer switching equipment (TSE)Primary

Specification data - Transfer switching equipment (TSE)

Standards

To IEC 60947-3 and 60947-6-1.

Short-circuit capability

PC.

Method of controlling transfer

ATSE.

Operating sequence

I-O-II.

Operating mechanism

Automatic.

Guidance for specification option:

Consult manufacturer for details.

Rated operational voltage (Ue)

415 V.

Rated impulse withstand voltage (Uimp)

6 kV.

Rated insulation voltage (Ui)

800 V.

Rated operational current (Ie)

40 A.

Guidance for specification option:

Available for OMD300 and OMD800 controllers only.

63 A.

Guidance for specification option:

Available for OMD300 and OMD800 controllers only.

100 A.

Guidance for specification option:

Available for OMD300 and OMD800 controllers only.

160 A.

Guidance for specification option:

Available for Level 2 (DIP) and Level 3 (LCD) controllers only.

250 A.

Guidance for specification option:

Available for Level 2 (DIP) and Level 3 (LCD) controllers only.

400 A.

Guidance for specification option:

Available for Level 2 (DIP) and Level 3 (LCD) controllers only.

630 A.

Guidance for specification option:

Available for Level 2 (DIP) and Level 3 (LCD) controllers only.

800 A.

Guidance for specification option:

Available for Level 2 (DIP) and Level 3 (LCD) controllers only.

1000 A.

Guidance for specification option:

Available for Level 2 (DIP) and Level 3 (LCD) controllers only.

1250 A.

Guidance for specification option:

Available for Level 2 (DIP) and Level 3 (LCD) controllers only.

1600 A.

Guidance for specification option:

Available for Level 2 (DIP) and Level 3 (LCD) controllers only.

Utilization category

Guidance for specification option:

Consult manufacturer's literature for details and insert requirements.

Rated operational frequency

50–60 Hz.

Number of poles

Four.

Rated short-time withstand current (Icw)

30–400 A, 100 ms: 18–30 kA.
260–800 A, 100 ms: 42 kA; 500 ms: 30 kA.
800–1600 A, 100 ms: 50 kA; 500 ms: 50 kA.

Rated short-circuit making capacity (Icm)

Manufacturer's standard.

Guidance for specification option:

Dependent on switch size, consult manufacturer for details.

Service conditions

Normal.

Terminals

Guidance for specification option:

Consult manufacturer for options and insert requirements.

Controls

-

Type

Open style operation, OMD300 controller.

Open style operation, OMD800 controller.

Open style, Level 2 DIP controls.

Guidance for specification option:

Bottom entry.

Source 1 and Source 2 connections on bottom, load connections on top.

Open style, Level 3 LCD controls.

Guidance for specification option:

Bottom entry.

Source 1 and Source 2 connections on bottom, load connections on top.

Display type

Manufacturer's standard.

Guidance for specification option:

Dependent on control type specified. Consult manufacturer for details.

Illuminated display to indicate the following conditions

Manufacturer's standard.

Guidance for specification option:

Dependent on control type specified. Consult manufacturer for details.

Communication module

Integral with controls to allow remote monitoring and operation of switch.

Guidance for specification option:

Consult manufacturer's literature for options and insert details under Accessories below.

Enclosure

-

Ingress protection (minimum)

To IEC 60529, IP65.

Impact protection (minimum)

Manufacturer's standard.

Material

Low-carbon sheet steel.

Finish

Manufacturer's standard.

Colour

Grey.

Integral features

No bypass.

Accessories

Guidance for specification option:

Consult manufacturer's literature for options and insert requirements, or omit.

Intruder resistance

SR2.

Sustainability data

Material

Steel

Guidance for specification option:

Enclosure.