NBS Source
I'm a manufacturer
Compare variants

Application

Suitable for use with misaligned doors, timber doors, glass doors and aluminium doors.

Description

The new ES8100, also known as the V-lock, contains a high torque motorised bolt which moves into a V shaped Strike Plate, pulling the door into alignment, when locked.


The ES8100 incorporates many improvements over its predecessor, the ES8000, including a higher preload rating of 100kg, Door Position Monitoring, integrated LED lock status and diagnostics visual indication, increased door misalignment correction from 7mm to 12mm, an IP53 rating for external door applications and simple, one-step, PTO/PTL onsite configuration.


The ES8100 can be mounted either vertically or horizontally but cannot be mounted in the floor. The ES8100 V-lock can be mortice mounted and concealed from view or surface mounted, with the inclusion of an optional kit.


Features and benefits:

  • A high holding force of 1000kg
  • Integrated LED lock status and diagnostics visual indication making installation easier
  • Door Position and Lock Status Monitoring
  • To EN 14846

General information

Color

Silver

Finish

Stainless steel

Material

Stainless steel

Shape

Rectangle

Length

256 mm

Width

41 mm

Height

256 mm

Warranty description

Two year

Uniclass

Pr_30_36_08_84 Special function door locksPrimary

CAWS

P21/26 Special function door locks

P21/530 Special function door locks

Product range

TRIMEC Electric Locking / TRIMEC Electromechanical Bolts

Specification data - Special function door locks

Standards

To EN 14846.

Accessories

Not required.

ES8000-IK-FD30 , TRIMEC ES8000 V-LOCK INTUMESCENT KIT TO SUIT FD30

ES8000-IK-FD60, TRIMEC ES8000 V-LOCK INTUMESCENT KIT TO SUIT FD60

Lock type

V-lock.

Motorised bolt lock.

Category of use

Medium duty.

Material and finish

Stainless steel lock body and faceplate.

Glass door kit

Not required.

218000-000.

Voltage

12–24 V d.c.

Guidance for specification option:

12V (+15% - 0%) 24V(+/- 15%).

Current

Minimum 1 A regulated supply.

Monitoring

COM, NO, NC.

Guidance for specification option:

NO terminal, NC terminal and COM terminal.

Voltage free changeover contacts rated at 48 dc/100mA.

Manufacturer guidance

Door status monitor.

Security

To AS4145.2- 1993, Passed S3.

Strength

1000 kg.

Guidance for specification option:

Maximum; with supported strike plate.

Mechanism endurance

300 000 operations.

OperationalTemperatureRange

-20°C to + 60°C.

BoltSize

11 mm diameter.

Bolt projection

20.5 mm.

Sustainability data

Contains Red List materials

No

Country of product manufacture

Australia

Recyclability

-

Manufacturer guidance

Metals widely recycled.