Verified by manufacturer 11 days ago
High-specification embossed (No Foil) multi-layer damp-proof course (DPC) specifically developed for use on brownfield and contaminated construction sites.
High-specification embossed multi-layer damp-proof course (DPC) specifically developed for use on brownfield and contaminated construction sites.
Designed to be sufficiently durable to build into perimeter cavity and load bearing walls as part of a gas barrier membrane system to resist moisture and ground gases, including volatile organic compounds (VOCs), hydrocarbons and others, such as methane, radon and CO₂.
Feature and benefits:
Color | Grey |
Finish | Embossed |
Material | Polyethylene Polymer |
Shape | Rectangle |
Length | 20000 mm |
Width | 300 mm 450 mm 550 mm 600 mm 650 mm |
Height | 0.5 mm Guidance for specification option: Thickness. |
Uniclass | |
CAWS | F30/360 Gas-resistant damp-proof courses/ cavity trays F30/54 Gas-resistant dpcs/ cavity trays |
Material | Polyethylene (PE)/ ethylene vinyl alcohol (EVOH). |
Compatibility | Suitable for use with adjoining gas-resistant dpms. |
Colour | Grey. |
Thickness | 0.5 mm. |
Roll width | 300 mm. 450 mm. 550 mm. 600 mm. 650 mm. |
Roll length | 20 m. |
Weight | 483 g/m². |
Reaction to fire | To DIN EN ISO 11925-2/ EN 13501-1, Class E. |
Watertightness | To DIN EN 1928 - Method B, watertight (at 60 kPa - 24 h and 500 kPa - 72 h). |
Resistance to impact | To DIN EN 12691 - 350 mm drop, watertight. |
Static load resistance | To DIN EN 12730, 20 kg (pass). |
Durability | Against thermal ageing at 60 kPa to DIN EN 1928, watertight. |
Puncture resistance | 3 mm puncture force to ASTM D2582, 36.9 N. |
Tensile strength | To ASTM D638-03, machine direction (MD) 20.9 N/50mm; cross direction (CMD) 23 N/50mm. |
Elongation | To ASTM D882-02, machine direction (MD) 739%; cross direction (CMD) 1078%. |
Tear resistance | Nail shank to DIN EN 12310-1. DIN EN ISO 291-23/50-2, machine direction (MD) 428 N; cross direction (CMD) 404 N. |
Shear resistance of joints (to EN 12317-2) | To DIN EN 12317-2, machine direction (MD) 228 N/50mm; cross direction (CMD) 166 N/50mm. |
Water vapour transmission | To DIN EN 1931 - Method B, 0.767 g/m²/day. |
Methane permeability | To ISO 15105-1, ≤0.09 mL/m²/day/atm. |
Radon permeability | To SP method 3873, 1.2E-12 m²/s. |
Carbon dioxide transmission rate | To ISO 15105-1, 0.37 mL/m²/day/atm. |
Accessories | None. Rhinoplast Evolution gas barrier. Guidance for specification option: Can be specified separately. Rhinoplast single-sided gas-resistant detail strip. Guidance for specification option: 75 mm wide, 20 m roll. LT Jointstrip double-sided tape. Guidance for specification option: 50 mm wide, 15 m roll. Gas resistant detailing strip. Guidance for specification option: 300 mm wide, 20 m roll. |
Material | Polyethylene Polymer |