Verified by manufacturer 4 months ago
Façade system with up to 30 minutes' of fire protection.
Suitable for external use in protecting building roofs and inside areas against fire risks.
Fire-resistant façade, fully tested in accordance with EN 13643-3, providing 30 minutes' of fire resistance in the vertical and roof area, meeting the requirements of fire resistance classes EI30 and EW30. The multi-functional aluminium construction is visually identical to a standard Schüco façade allowing a harmonious façade design throughout with a 50 mm profile face width.
The system can be used in the vertical area due to its CE marking in accordance with EN 13830 and country-specific approvals are available for the skylight area.
Features and benefits:
Standards:
Color | Silver Other |
Finish | Powder-coated Anodized |
Material | Aluminium Glass |
Width | Bespoke |
Height | Bespoke |
Uniclass | |
CAWS | H11/110 Curtain walling |
System performance | Fire performance to BS EN 13501: F30; G30; EI30; EW30.Guidance for specification option: Consult manufacturer’s literature for further details. |
Framing | |
Frame members | Aluminium curtain wall frame sections, polyester powder-coated.Guidance for specification option: Insert colour requirements. Aluminium curtain wall frame sections, anodized.Manufacturer guidanceMinimum face width: 50 mm. Uf-value of frame: To EN ISO 10077-2, ≥1.1 W/m²K. |
Frame accessories | Manufacturer guidanceConsult manufacturer for options and insert requirements, or omit. |
Fasteners | Manufacturer's standard. |
Cladding units | |
Glass units | Manufacturer guidanceInsert requirements, 13–52 mm thick. |
Glazing accessories | Manufacturer guidanceInsert requirements or omit. |
Panels and facings | |
Material | Aluminium.Not required. |
Thermal insulation | Manufacturer guidanceInsert requirements or omit. |
Internal linings | Manufacturer guidanceInsert requirements or omit. |
Fasteners | Manufacturer's standard. |
Perimeter seals | Manufacturer's standard. |
System accessories | Manufacturer guidanceConsult manufacturer for options and insert requirements, or omit. |
Face width | 50 mm. |
Thermal transmittance (U-Value) | Manufacturer guidanceInsert requirements or consult manufacturer for values. Uf value of frame: ≥ .1 W/m²K. |
Burglar resistance | Manufacturer guidanceInsert requirements; up to EN 1627, RC 2 (WK2). |
Air permeability | To EN 12152, Class AE. |
Watertightness | To EN 12154, Class RE 1200. |
Resistance to wind load | To EN 12179, 1.2 kN/m². Guidance for specification option: Permissible load (in kN/m²), Positive wind load: +1.2, negative wind load: -1.2. Increased load (in kN/m²), Positive wind load: +1.8, negative wind load: -1.8. |
Impact resistance | To EN 14019, I5/ E5. |
Standards | To DIN 4102; EN 1364; EN 13501-2; DIN EN 13830. Guidance for specification option: CE marked. |
Label | Schueco ‘IoF’ ID tag with QR code. Guidance for specification option: Internet of facades (IoF) ID tag with unique QR code linked to the product data, ongoing maintenance instructions and installation records. |
Country of material origin | United Kingdom |
Material | Aluminium Glass |
Platform | Compatible | Version |
---|---|---|
- | 1 |
Add-On Construction (AOC)
Blast-resistant stick curtain walling façade system - FW 60+ XR
Concealed vent stick curtain walling façade system - FWS 60 CV
Fire-resistant Steel Stick Curtain Walling Façade System - VISS Fire
Fire-resistant stick curtain walling façade system - FW 60+ BF
Fire-resistant stick curtain walling façade system - FW50+ FR60
Highly Thermally Insulated Steel Stick Curtain Walling Façade System - VISS 50
Highly Thermally Insulated Steel Stick Curtain Walling Façade System - VISS 60
Slimline Panorama design stick curtain walling façade system - FWS 35 PD
Slimline stick curtain walling façade system - FWS 50 SG