NBS Source
I'm a manufacturer

FireStop Ei60 Double Glazed Partition System

Verified by manufacturer 5 days ago

Radii Third party certifications:
  • ISO 9001 Quality Management

    Certificate type

  • ISO 45001 Health and Safety Management

    Certificate type

  • ISO 14001 Environmental Management Systems

    Certificate type

  • ISO 140-3/ ISO 717-1 Sound Reduction Index Test Report

    ISO 140-3/ ISO 717-1 Sound Reduction Index Test Report

    Certificate type

Double glazed fire rated steel framed partition system.

Jump to:
+44 (0)20 7952 4830 Website

Application

All sectors: Commercial, Education, Healthcare, MOD, Airport & Rail, Industrial, Hospitality, Residential, & Public. Consult manufacturer for details.

Description

Double glazed fire rated steel framed partition system.


Features and benefits:


  • The FireStop glazed partitioning and door range achieves up to Ei60 (integrity + insulation) on fixed screens and up to Ei60 on doors. Utilizing robust thermally broken and insulated steel profiles it offers extreme levels of fire protection for even the most stringent of fire requirements, making it suitable for even the most demanding of applications.
  • Also available in Ei60 single glazed format or Ei30 (single or double glazed). All specified separately.


Please note that acoustic, fire rated and structural certification and support for our products and systems is available on a project-specific basis. Please contact the specification team directly for further information.

General information

Color

Other

Guidance for specification option:

Any RAL code.

Finish

Powder-coated

Guidance for specification option:

Polyester powder-coated.

Material

Steel

Glass

Shape

-

Manufacturer guidance

To suit project requirements; consult manufacturer for further details.

Length

Bespoke

Width

Bespoke

Height

Bespoke

Warranty description

-

Manufacturer guidance

Dealt with on a project specific basis as part of the O&M process; consult manufacturer for details.


Uniclass

Pr_25_71_57_60 Partition panelsPrimary
Ss_25_12_65_65 Panel partition systems

CAWS

K30/130 Relocatable partition system

K30/10 Relocatable partition system

Product range

Fire Rated Systems / FireStop

Specification data - Partition panels

Third party accreditation

ISO 9001-UKAS (Quality); ISO 14001-UKAS (Environmental); Constructionline-Gold; Acclaim (SIPP); Achilles (Building confidence, SIPP); EPD - material accreditation & compliance; FIS Member; Considerate Construction; FORS Bronze; Build Profile.

Guidance for specification option:

EPD - material accreditation & compliance: Consult manufacturer for details (glass, PPC, aluminium, timber, ironmongery, waste, adhesive and more).

Unit size

-

Thickness

108 mm.

120 mm.

Partition height (nominal)

-

Manufacturer guidance

Consult with manufacturer to ensure compliance with certification.


Width (nominal)

-

Manufacturer guidance

Consult with manufacturer to ensure compliance with certification.


Deflection allowance (maximum)

-

Head

Excluding deflection, excluding blinds: 60 mm-deep x 108-mm wide steel insulated channel.

Excluding deflection, including blinds: 60 mm-deep x 120-mm wide steel insulated channel.

±25 mm deflection, excluding blinds: 112 mm-deep x 141 mm-wide steel insulated two-part channel.

±25 mm deflection, including blinds: 112 mm-deep x 155 mm-wide steel insulated two-part channel.

Floor

-

Manufacturer guidance

Consult with manufacturer for system weight.


Verticals

Excluding blinds: 60 mm-deep x 108 mm-wide steel insulated channel.

Including blinds: 60 mm-deep x 120 mm-wide steel insulated channel.

Manufacturer guidance

Corners: glass-to-glass joints.

Panel partition type

Frameless glass - double glazed.

Framing, junctions, corners

As Verticals.

Joint treatment

-

Type

Butt jointed glazing; double glazed, fire-rated silicone joints.

Guidance for specification option:

Consult with manufacturer to ensure compliance with test/assessment data.

  • Primary fire rated glazing (17 mm): fire rated silicone.
  • Secondary sacrificial glazing: (10-21.5 mm).
  • Vertex PVC translucent cross dry joint, (1.5 mm visible, glass edge prep required).
  • Linea PET-G translucent or black dry joint (5 mm visible, glass edge prep required).
  • Nova SAA / PPC aluminium dry joint (13 mm visible, glass edge prep required).
  • Solar PVC-U translucent ‘H’ joint (12 mm visible).
  • Acrylic glazing tape, translucent (2 mm visible).


Finish and colour

Coloured silicone.

Guidance for specification option:

Consult manufacturer and insert requirements.

Glazed panels

-

Type

Primary fire rated glazing: 17 mm annealed multi-laminate fire glass; Secondary sacrificial glazing: (10-21.5 mm)/

Integral blinds

Tilt / turn manual venetian blinds with blind control knob (fire risk side only).

Guidance for specification option:

Two panels maximum.


Tilt / turn battery powered venetian blinds, remote control operation.

Guidance for specification option:

One white sensor battery pack per blind.


Not required.

Door arrangement

-

Type

-

Manufacturer guidance

Consult with manufacturer for details and insert requirements.


Door frames

-

Manufacturer guidance

Consult with manufacturer for details and insert requirements.


Door leafs

-

Type

-

Manufacturer guidance

Consult with manufacturer for details and insert requirements.


Ceiling

-

Type

-

Manufacturer guidance

Consult manufacturer for interface detail and insert requirements.


Method of support

-

Manufacturer guidance

Consult manufacturer for support detail and insert requirements.


Perimeters, skirtings, sills

Excluding blinds: 60 mm-deep x 108 mm-wide steel insulated channel.

Including blinds: 60 mm-deep x 120 mm-wide steel insulated channel.

Manufacturer guidance

Corners: glass-to-glass joints.

Hardware

-

Manufacturer guidance

Consult manufacturer and insert requirements.


Seals

Primary fire glass: intumescent silicone.

Other features

-

Manufacturer guidance

Consult manufacturer and insert requirements or leave blank.


Product Reference

FireStop Ei60 Double Glazed Partition System

Manifestation

Allowance of 2 nr rows 50 mm dots or square (minimum) Opal Frost.

Guidance for specification option:

Insert requirements.


Artwork and custom manifestation to client design.

Guidance for specification option:

Insert requirements.


Manufacturer guidance

To architects choice and in accordance with the requirements of Approved Document K.


StrengthGrade

-

Manufacturer guidance

Consult with the manufacturer to ensure the system complies with current regulations BS 5234:1992 non load-bearing screens not protecting a change in adjacent floor level of >380 mm.


For glass load resistance criteria;

  • BS 5234 not applied to “all glass partition screens”.
  • Nominal line load criteria of “short-term impact load” utilised.
  • 0.36 kN/m applied as linear load at 1100 mm above FFL.
  • Glass deflection limited to L/65 or 25 mm, whichever is less under load.
  • Maximum deflection and stress in accordance with the glass performance requirements of EN 572/ EN 12150/ EN 12543/ EN 14179 (where heat soaked).


Building regulations Part N (BS 6262 & BS EN 12600) + InsStucEng publication “structural use of glass in buildings” insert as required:

  • 0.36 kN/m (default load).
  • 0.74 kN/m.
  • 1.5 kN/m.


BS 6180:2011 barriers in and about buildings for Atria or protected change in adjacent floor level of >380 mm.

Horizontal uniformly distributed line load 1100 mm above FFL (glass deflection limited to L/65 or 25 mm, whichever is less relative to glass fixings).

Structural glass based on line-load and attendant UDL + point load, insert as required:

  • 0.74 kN/m.
  • 1.5 kN/m.
  • 3.0 kN/m.


Acoustic performance

47 dB Rw.

Guidance for specification option:

Excluding blinds.


48 dB Rw.

Guidance for specification option:

Excluding blinds.


49 dB Rw.

Guidance for specification option:

Including blinds.

50 dB Rw.

Guidance for specification option:

Including blinds.

Fire insulation

Ei60 (60/60 integrity and insulation).

Partition

Frameless glass - double glazed.

Fasteners

To manufacturer's specification, type, length and frequency to suit substrates.

Joint treatment

Butt jointed glazing.

Samples required

-

Manufacturer guidance

Consult with manufacturer.


Sustainability data

Contains Red List materials

No

Guidance for specification option:

No substance on the “Candidate List of Substances of Very High Concern for authorisation” derived under REACH is present either above the limits for registration with the European Chemicals Agency or in excess of 1 weight–% of the product.

Country of material origin

United Kingdom

Country of product manufacture

United Kingdom

Material

Steel

Glass

Recyclability

100%

Guidance for specification option:

Steel and glass.

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

-

Manufacturer guidance

17–28% for glass.

15–20% for steel.

Third party certifications

Third party certifications

ISO 9001 Quality Management

ISO 9001 Quality Management

ISO 9001 Certificate

ISO 45001 Health and Safety Management

ISO 45001 Health and Safety Management

ISO 45001 Certificate

ISO 14001 Environmental Management Systems

ISO 14001 Environmental Management Systems

ISO 14001 Certificate

ISO 140-3/ ISO 717-1 Sound Reduction Index Test Report

ISO 140-3/ ISO 717-1 Sound Reduction Index Test Report

Firestop Ei60 Multi-pane Double Glazed Partitioning System Acoustic Certificate

ISO 140-3/ ISO 717-1 Sound Reduction Index Test Report

ISO 140-3/ ISO 717-1 Sound Reduction Index Test Report

Firestop Ei60 Multi-pane Double Glazed Partitioning System with integral blind Acoustic Certificate

Literature

ISO14001 Certificate of Registration

ISO14001 Certificate of Registration

ISO45001 Certificate of Registration

ISO45001 Certificate of Registration

ISO9001 Certificate of Registration

ISO9001 Certificate of Registration

Radii Client Support & Aftercare Flyer

Radii Client Support & Aftercare Flyer

Similar products from Radii

2D Demountable Relocatable Crosswall System - Modular Wall System

2D Demountable Relocatable Crosswall System - Modular Wall System

Align Flush Bonded Glazed Pivoting Door - Pivoting Door

Align Flush Bonded Glazed Pivoting Door - Pivoting Door

FireClear100 Double  Glazed Partition System

FireClear100 Double Glazed Partition System

FireClear20  Single Glazed Partition System

FireClear20 Single Glazed Partition System

FireClear54 Double Glazed Partition System

FireClear54 Double Glazed Partition System

FireEco Ei30 Double Glazed Timber Framed Fire Rated Glass Partition System

FireEco Ei30 Double Glazed Timber Framed Fire Rated Glass Partition System

FireEco Ei30 Single Glazed Timber Framed Fire Rated Glass  Partition System

FireEco Ei30 Single Glazed Timber Framed Fire Rated Glass Partition System

FireEco Ei60 Double Glazed Timber Framed Fire Rated Glass Partition System

FireEco Ei60 Double Glazed Timber Framed Fire Rated Glass Partition System

FireEco Ei60 Single Glazed Timber Framed Fire Rated Glass  Partition System

FireEco Ei60 Single Glazed Timber Framed Fire Rated Glass Partition System

FirePro E120 Single Glazed Fire Rated Glass Partition System and Ei60 Fire Door

FirePro E120 Single Glazed Fire Rated Glass Partition System and Ei60 Fire Door