Verified by manufacturer 22 hours ago
UKAS
Certificate type
EN 13501-1 (Efectis)
Certificate type
CWCT Certificate
Certificate type
A1 non-combustible hook on cassette cladding system (secret fix) ; PVDF pre-coated solid aluminium panel; CWCT Standards tested; 30-year warranty; 100% compliance with Building Regulations.
Drained and back-ventilated rainscreen cladding systems.
The Hook on Cassette System is folded aluminium cassette panel that utilizes Futural 'hook on' panel, which combines contemporary aesthetics with uncomplicated fixing methods allowing for rapid installation time. It features Futural Cladding panels, support rails and brackets, and colour matched fixings.
It is a quick, cost-effective and CWCT tested cladding system solution which is available in both 2 and 3 mm aluminium and unlimited colour range.
Futural Cladding Panel
A1 non-combustible solid aluminium manufactured from marine grade aluminium and PVDF coatings; it is highly durable and impact resistant, yet available in unlimited colour range.
Compliant standards:
Features and benefits:
Color | Beige Black Blue Bronze Brown |
Finish | PVdF Gloss Matt Textured Smooth |
Material | Aluminium |
Shape | Rectangle Other |
Length | 2500 mm 3200 mm 4000 mm Bespoke |
Width | 1250 mm 1500 mm Bespoke |
Height | 2 mm 3 mm Bespoke |
Warranty description | 30 year |
Uniclass | |
CAWS | H92/120 Rainscreen cladding |
Description | A1 cassette cladding system (hook on/ secret fix). |
System manufacturer | FUTURAL (UK) LTD. |
Thermal insulation | Guidance for specification option: Mineral wool insulation, supplied by others; insert requirements. |
Breather membrane | |
Material | Guidance for specification option: Fire rated breather membrane, supplied by others; insert requirements. |
Fasteners | Guidance for specification option: Supplied by others; insert requirements. |
Secondary support structure | Futural aluminium support structure.Guidance for specification option: Insert requirements. |
Cavity fire barriers | |
Horizontal | Guidance for specification option: Seek specialist information from specialist manufacturers and insert requirements. |
Vertical | Guidance for specification option: Seek specialist information from specialist manufacturers and insert requirements. |
Cladding panels | |
Material | Futural aluminium cassette panels, 2 mm thick.Futural aluminium cassette panels, 3 mm thick.Manufacturer guidance
|
Panel joints | 20 mm standard joints in both vertical and horizontal directions. Closed joints. |
Reveals | Guidance for specification option: Insert requirements or omit. |
System accessories | Guidance for specification option: All necessary accessories are available including, flashings, copings, bullnose and drainage channel. Insert requirements, or omit if none required. |
Panel size | Guidance for specification option: Insert requirements.
|
Panel | Guidance for specification option: Refer to Futural Colour Chart and insert requirements, or contact manufacturer for full list of colour options. Manufacturer guidancePanel colour. |
Surface finish | PVDF coating. |
Fire performance | Non-combustible. Guidance for specification option: All system components are A1/ A2 non-combustible. |
Contains Red List materials | No |
Country of product manufacture | United Kingdom |
Material | Aluminium |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | 8.6 kg CO₂ eq/unit Self declared |
Recyclability | 100% |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 99.5 % |