NBS Source
I'm a manufacturer

GreenCoat® PLX Colour Coated Steel Fully Supported Traditional Angle Seam Facade Cladding - Standing Seam Roof

Verified by manufacturer today

Metal Solutions Limited Third party certifications:
  • EPD

    EPD

    Certificate type

  • R EACTION TO FIRE - CLASSIFICATION REPORT EUI-22-000041

    R EACTION TO FIRE - CLASSIFICATION REPORT EUI-22-000041

    Certificate type

  • ISO 9001 Quality Management

    Certificate type

  • IATF 169492016

    IATF 169492016

    Certificate type

GreenCoat PLX Pural standing seam can be used for roofs with a pitch of 3–7 degrees on buildings with humidity class of between 1–4 dwellings with high occupancy. Other uses - facade cladding.

Jump to:
+44 (0)1204 491800 Website

Application

The product can be used to cover complex surfaces such as barrel vaulted roofs and domes etc. It can be laid on a ventilated timber substrate, composite panel and direct onto insulation, using special warm roof fixing clips. Can also be employed to clad small surfaces such as dormers, fascias or gables.


As well as being used in a roofing application the system can also be used as traditional standing seam wall cladding, also known as angle seam cladding. This system offers tremendous opportunity to change cover widths to add interest to a facade project.


Installation:

A list of Approved Installers by postcode is available on request. Contact Email:

gaynor@metalsolutions.uk.com

Description

GreenCoat ® PLX Colour Coated Steel Angle Seam for use in Fully Supported Facade Applications.

The 25 mm single locked standing seam is formed by interlocking the sides of adjoining panels by single welting the top of the upstand of the seam.

The final fold is turned parallel to the cladding surface. This means it is less watertight than the double lock standing seam.

The angled standing seam is used for vertical cladding where a more definitive visual line is required and is not recommended for slopes below 35°

Features and benefits:

  • Manufactured from a specialist sustainable colour coated steel made with rapeseed coating.
  • Material - A1 fire rated.
  • Seams are available in 25 mm or 38 mm formats.
  • The system can be provided as a complete roof kit including all flashing, matching rainwater products and ancillaries.

Substructure:

Suitable substructure materials:

  • Ventilated 18 mm-thick weather and boil proof (WPB) plywood.
  • Ventilated oriented strand board OSB3.
  • Composite panel.
  • Rigid insulation.
  • Profiled metal deck.
  • Non-combustible options available.

Underlay:

ISO-Mat Pro® underlay is recommended for cold roof applications.

ISO-Mat Metal® underlay is recommended for warm roof applications.

Available from:

roofing-tool.com

Clips:

  • Fixed: 25 mm clips.
  • Sliding: 25 mm clips
  • Fixings to suit substrate.

Installation:

Contact Metal Solutions for a list of Approved Installers by postcode

Email

gaynor@metalsolutions.uk.com

General information

Color

Black

Grey

Silver

White

Bronze

Show more

Finish

Coated

Smooth

Textured

Material

Steel

Shape

Rectangle

Length

6000 mm

Width

430 mm

Height

0.6 mm

Warranty description

50 year

Guidance for specification option:

Technical warranty.

25 year

Guidance for specification option:

Aesthetical warranty.

Uniclass

Ss_25_20_50_11 Carbon steel sheet fully supported wall-covering systemsPrimary

CAWS

H31/10 Metal

H31/120 Metal

Specification data - Carbon steel sheet fully supported wall-covering systems

Standards

To ISO9001, EN 13501-1: A1, Broof EN-13501-5, REACH (1907/2006/EC), CLP (1272/2008/EC), EN-ISO 1716, EN-14782, EN – 14783, EN-10169, EN-10346, EN-10219, EN-10025-2, EN-10025-3, EN-10025-6, EN-10130, EN-10268, EN-10346, EN-10021, EN-10204.

Alloy

Carbon steel.

Colour/ Finish

Nordic Night Black.

Guidance for specification option:

GreenCoat PLX Pural BT or GreenCoat PLX Pro BT finish, insert requirements.

Mountain Grey.

Guidance for specification option:

GreenCoat PLX Pural BT or GreenCoat PLX Pro BT finish, insert requirements.

Anthracite Grey.

Guidance for specification option:

GreenCoat PLX Pural BT or GreenCoat PLX Pro BT finish, insert requirements.

Metallic Dark Silver.

Guidance for specification option:

GreenCoat PLX Pural BT finish.

Metallic Silver.

Guidance for specification option:

GreenCoat PLX Pural BT finish.

Show more

Size and profile

Guidance for specification option:

Optimised panel widths are based on available coil widths (some colours will vary).

Cladding: 430 mm wide (x 6 metres long maximum).

Consult manufacturer and insert requirements.

System accessories

25 mm Fixed clips, RFC-25, breather membrane.

30 mm Fixed clips, RFC-30, structured underlay.

38 mm Fixed clips, SM-EFK-38, breather membrane.

25 mm Sliding clips, RSC-25, breather membrane.

30 mm Sliding clips, RSC-30, structured underlay.

Show more

Carriers

Guidance for specification option:

As design.

Roofing substrate

18 mm Plywood.

Guidance for specification option:

The European Standard is EN 636-3 - for use in exterior conditions including liquid, water or water vapour in damp but ventilated locations.

Service Class 3 in Euro Code 5 covers plywood to be used in climate conditions leading to a higher moisture content than in service class 2.

The minimum board thickness must be 18 mm (or layers of thinner boards that combine to achieve the minimum 18 mm thickness for curved coverings).

The plywood face laminate must be free of knots and defects and should as a minimum be "Good one side". shuttering ply is not suitable.

18 mm OSB (Oriented Strand Board).

Guidance for specification option:

Also known as sterling board, it is formed by layered flakes of wood in specific orientation. Its wooden strips are compressed and bonded together with wax and resin adhesive. It is a cost effective option.

Care must be exercised when used as a substrate under traditional metal roofing and should be protected from moisture during construction. It is advised that screw fixings are used to ensure good pull-out values.

24 mm Timber or sarking board decking.

Guidance for specification option:

Complies with 8S5268: Part 2 (strength class SC3), or EN 1611-1:1999 (sawn timber normally with a maximum moisture content of 22%).

There are some woods which are not compatible with roofing metals, due to high acid content.

UK recommended practice is a range of 18 mm to 25 mm thickness, in widths of 100 mm to 125 mm and laid with 3–5 mm gaps between the boards parallel to the eaves.

In some cases, because of the nature of the building's structure, a diagonal boarding layout is used.

It is particularly important to note that timber protectives, preservatives and adhesives used in plywood board construction can react with the roofing metal and if applicable, suitable separation layers must be used.

Rigid insulation.

Guidance for specification option:

Insulation must be structurally self-supporting or supported when installed so that it will not sag and form unvented voids or cause loss of thermal efficiency.

An insulation used as a directly supporting substrate must have a minimum compression strength of 50kPa (0.5kg/cm2) with deformation limited to a maximum of 10%.

The insulation must also be dimensionally stable up to 100C. Warm roof fixings including stainless toothed plate and sliding clip, plastic peg and fixing screws are used in conjunction with an insulated deck.

Composite panel.

Guidance for specification option:

The composite panel is constructed from factory produced interlocking steel or aluminium panels, encasing an insulation core (PIR or other). The panels are laid across the roof or wall supporting rafters or rails.

The interlocking joints must be sealed with gaskets or sealant and taped according to the manufacturer's recommendations, with sealed metal closures to hips ridges, verges, eaves and penetrations. The total area and abutments must be sealed airtight.

This type of construction gives a good vapour sealed substrate and can be quickly constructed.

Show more

Manufacturer guidance

Choice of base substrates, further guidance from manufacturers own technical team.

Typical system build up:

•            Interior Finish.

•            Vapour Barrier.

•            Insulation.

•            Breather Membrane.

•            Ventilated Air Space (minimum of 38 mm for wall) created with the use of timber battens or a non-combustible bracket and rail system.

•            Fully supported substrate (see options).

•            Breather Membrane.

•            Metal Panels.

Cavity barriers

Guidance for specification option:

to design specification.

Fasteners

Timber, stainless screw, SPT-R-S-4.3x20-RS.

Timber, annular ringshank nail, RSN-SS25.

Metal, stainless screw, SX2-D9-4.8x22 or DS3-SS-SF-4.8x16.

Manufacturer guidance

Fasteners to suit substrate.

Separating layer

Breather membrane.

Guidance for specification option:

The breather membrane must comply with EN 13859-1 for roofs and EN 13859-2 for walls and must also be CE compliant.

The breather membrane must be fully supported, lapped and sealed and then further sealed to all surrounding abutments and surface penetrations.

ISO-Mat Pro® underlay.

Guidance for specification option:

Recommended for cold roof applications.

ISO-Mat Metal® underlay.

Guidance for specification option:

Recommended for warm roof applications.

Envirotect Class B-S1, Envirotect Class B-S1, D0 fire walling membrane

Guidance for specification option:

Can be used when a non-combustible option is required.

Insulation

Guidance for specification option:

Traditional angled seam cladding does not have any specific requirement with regard to the insulation.

Insulation must be structurally self-supporting or supported when installed so that it will not sag and form unvented voids or cause loss of thermal efficiency. An insulation used as a directly supporting substrate must have a minimum compression strength of 50 kPa (0.5 kg/cm²) with deformation limited to a maximum of 10%. The insulation must also be dimensionally stable up to 100℃.

All insulation must be kept dry and protected prior to metal covering being laid.

Vapour barrier

Alutrix 600 Vapour Barrier.

Guidance for specification option:

Some manufacturer's recommendations for warm roof constructions require a minimum of 5 screw fixings per M2 through the VB, therefore this type of VB must have the properties of self-sealing around screw fixings when penetrated. In this instance, it is accepted that a VB with an aluminium foil face and a polymer bitumen core and self-adhesive properties offers the best performance. Alutrix complies with this requirement.

Alutrix FG35 Primer.

Guidance for specification option:

to be used on porous substrates.

Some manufacturer's recommendations for warm roof constructions require a minimum of 5 screw fixings per M2 through the VB, therefore this type of VB must have the properties of self-sealing around screw fixings when penetrated. In this instance, it is accepted that a VB with an aluminium foil face and a polymer bitumen core and self-adhesive properties offers the best performance. Alutrix complies with this requirement.

Manufacturer guidance

Vapour Barrier membranes must comply with EN 13859-2 for walls and must also be CE compliant.

For fully supported metal roofs the VB must have a minimum water vapour resistance of 4000MNs/g and comply to BS SO 12572.

The VB must have a resistance against a supported column of water 2M high for a period of 15 mins to comply with DIN EN 20811.

All roofs must have a Vapour Barrier regardless of being ventilated, unventilated cold or warm in design. The VB must be positioned below the insulation, or for vertical cladding, behind the insulation and on the warm side of the construction.

Joints

Single lock cross welt 18 mm.

Weight

0.6 mm material weight 4.62 kg/m².

Guidance for specification option:

System weight dependant on seam centres.

Reaction to fire

To EN 13501-1, A2-s1,d0.

Sustainability data

Contains Red List materials

No

Country of material origin

Sweden

Country of product manufacture

United Kingdom

Manufacturing plant location

Material

Steel

Embodied carbon

A1-A3 (production stage) as defined in BS EN 15804

2.63 kg CO₂ eq/kg

Recyclability

95%

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

20 %

Third party certifications

Third party certifications

EPD

EPD

Greencoat colour coated steel EPD

R EACTION TO FIRE - CLASSIFICATION REPORT EUI-22-000041

R EACTION TO FIRE - CLASSIFICATION REPORT EUI-22-000041

Greencoat PLX Pural BT - Fire Accreditation

R EACTION TO FIRE - CLASSIFICATION REPORT EUI-22-000041

R EACTION TO FIRE - CLASSIFICATION REPORT EUI-22-000041

Greencoat Pro BT Fire certifications

ISO 9001 Quality Management

ISO 9001 Quality Management

ISO 9001 Metal Solutions

ISO 9001 Quality Management

ISO 9001 Quality Management

SSAB-Europe-Management-system-certificate-9001-EN-2018-03

IATF 169492016

IATF 169492016

SSAB IATF 169492016

Literature

SSAB - 2019 UK GreenCoat story

SSAB - 2019 UK GreenCoat story

SSAB EPD GreenCoat - color coated steel sheets and coils

SSAB EPD GreenCoat - color coated steel sheets and coils

SSAB - GreenCoat Colours

SSAB - GreenCoat Colours

SSAB-GreenCoat-EPD-Color-Coated-Steel-Sheets

SSAB-GreenCoat-EPD-Color-Coated-Steel-Sheets

SSAB - GreenCoat-European guarantee

SSAB - GreenCoat-European guarantee

SSAB - GreenCoat Inspection and maintenance

SSAB - GreenCoat Inspection and maintenance

SSAB - GreenCoat Installation Guide

SSAB - GreenCoat Installation Guide

SSAB - GreenCoat PLX Pro BT

SSAB - GreenCoat PLX Pro BT

SSAB - GreenCoat PLX Pural BT

SSAB - GreenCoat PLX Pural BT

SSAB - GreenCoat Pro BT

SSAB - GreenCoat Pro BT

SSAB - GreenCoat Pural BT

SSAB - GreenCoat Pural BT

SSAB Greencoat Pural BT, Pural BT Matt VTT-S-00613-18

SSAB Greencoat Pural BT, Pural BT Matt VTT-S-00613-18

SSAB PX29354-1 EN 13501-1  Emea AB

SSAB PX29354-1 EN 13501-1 Emea AB

Metal Solutions Snow Guard System

Metal Solutions Snow Guard System

Metal Solutions Rainwater System

Metal Solutions Rainwater System

Metal Solutions - ISO 9001 2015 Certificate

Metal Solutions - ISO 9001 2015 Certificate

Greencoat - Broof EN13501-5

Greencoat - Broof EN13501-5

Case studies

GreenCoat PLX Pural Metallic Dark Silver - Private Residence, Killearn

GreenCoat PLX Pural Metallic Dark Silver - Private Residence, Killearn

GreenCoat PLX Pro Mountain Grey - 'Tranquil London Extension'

GreenCoat PLX Pro Mountain Grey - 'Tranquil London Extension'

GreenCoat PLX Nordic Night Black - 'The Devil is in the Details'

GreenCoat PLX Nordic Night Black - 'The Devil is in the Details'

GreenCoat PLX Glacial Green - Aspext, Wick Lane, London E3

GreenCoat PLX Glacial Green - Aspext, Wick Lane, London E3