NBS Source
I'm a manufacturer

iQ Toro Static Conductive

Verified by manufacturer 6 months ago

Tarkett

Homogeneous vinyl sheet floor covering, suitable for a wide range of uses.

Jump to:
+44 (0)1233 746020 Website

Application

  • Suitable for a wide range of uses, ranging from education and healthcare to offices and public buildings.
  • Permanently static-conductive flooring for use in operating theatres, laboratories, x-ray and clean rooms.


Description

Homogeneous static control vinyl sheet floor covering, suitable for a wide range of uses ranging from education and healthcare, to offices and public buildings. The quality and composition of the overall thickness, combined with third generation PUR, means that iQ Toro SC needs no wax or polish, improving maintenance properties.


Features and benefits:

  • Timeless design and fresh colour offering.
  • iQ unique surface restoration.
  • iQ PUR reinforced.
  • High performance wear class P.
  • Multicolour and plain weld rods.
  • Conforms to BS EN 649 and is CE marked.
  • Suitable for underfloor heating up to maximum of 27°C.
  • Ease of decontamination rated 'Excellent' to ISO 8690/ DIN 25415.
  • Phthalate-Free.
  • Environmental Product Declaration.
  • Material Health Statement.
  • Tarkett Circular Selection.
  • Clean installation off-cuts 100% closed-loop recyclable. Free of charge collection via Tarkett ReStart.

General information

Color

Grey

Black

White

Beige

Yellow

Show more

Manufacturer guidance

Range of 14 colours available, consult manufacturer for details.

Finish

Smooth

Material

Vinyl

Guidance for specification option:

Homogeneous.

Shape

Rectangle

Length

23000 mm

Width

2000 mm

Height

2 mm

Warranty description

Ten year

Uniclass

Pr_35_57_71_67 Polyvinyl chloride (PVC) sheetsPrimary

CAWS

M50/150 Sheeting

M50/20 Sheeting

Product range

Sheeting / Homogeneous Vinyl

Specification data - Polyvinyl chloride (PVC) sheets

Standard

To BS EN 14041 and BS EN ISO 10581 for homogeneous vinyl flooring.

Use class

To BS EN ISO 10874, class 34.

Guidance for specification option:

Commercial.

To BS EN ISO 10874, class 43.

Guidance for specification option:

Industrial.

Recycled content

To BS EN ISO 14021, 25.5%.

Width

2000 mm.

Guidance for specification option:

To EN ISO 24341.

Thickness

2.0 mm.

Guidance for specification option:

To ISO 24346.

Colour and pattern

3093 101 Grey.

3093 102 Dark grey.

3093 578 Grey.

3093 103 Black.

3093 570 White.

3093 104 Beige.

3093 572 Light yellow.

3093 573 Brown yellow.

3093 105 Yellow beige.

3093 574 Light brown.

3093 575 Brown.

3093 107 Light blue.

3093 576 Green.

3093 100 Light grey.

Manufacturer guidance

Range of 14 colours available, consult manufacturer for details.

Roll length

23 m.

Guidance for specification option:

To EN ISO 24341.

Binder

Type I.

Guidance for specification option:

To EN ISO 10581.

Surface treatment

iQ PUR.

Residual indentation (to EN-ISO 24343-1)

0.02 mm.

Guidance for specification option:

Best measured value.

Manufacturer guidance

Required value: ≤ 0.10 mm.

Castor chair continuous use (to ISO 4918)

Suitable.

Electrostatic charge (to EN 1815)

< 2 kV.

Cleanroom particle emission (to ISO 14644-1)

ISO class 4.

VOC emission to ISO 16000-6, EN 10580

≤ 10 μg/m³.

Guidance for specification option:

After 28 days.

Manufacturer guidance

  • AgBB/ DIBt: Confirm.
  • Indoor air quality: Platinum.
  • Floor score: SCS certified.

Light fastness (to BS EN ISO 105 B02)

Level 7.

Chemical resistance (to EN-ISO 26987)

Excellent.

Bacteria resistance (to EN846)

Does not favour growth.

Manufacturer guidance

Part C.

Ramp slip resistance (to DIN 51130)

R9.

Slip resistance (to EN 13893)

μ ≥ 0.3.

Reaction to fire (to BS EN 11925-2 and BS EN 13501-1)

Pass, Bfl-s1.

Fire behaviour (to BS EN ISO 9239-1)

≥ 8 kW/m².

Total weight (to EN ISO 23997)

2950 g/m².

Wear layer thickness

2.0 mm.

Guidance for specification option:

To ISO 24340.

Electrical insulation to ground (to DIN VDE 0100)

Ri ≤ 5 x 10^4 Ω.

Manufacturer guidance

Part 600.

Electrical resistance (to EN 1081)

R ≤ 10^9 Ω.

Guidance for specification option:

ESD-approval SP method 2472.

R1: 5 x 10^4 ≤ R ≤ 10^6 Ω.

Guidance for specification option:

ESD-approval SP method 2472.

R2: 5 x 10^4 ≤ R ≤ 10^6 Ω.

Guidance for specification option:

ESD-approval SP method 2472.

R 5 x 10^4 ≤ R ≤ 10^6 Ω.

Guidance for specification option:

EN/ IEC 61340-4/ 100 V.

≤ 3.5 x 10^7 Ω.

Guidance for specification option:

EN/ IEC 61340-4-5.

Accessories

Tarkett ReStart recycling service.

Guidance for specification option:

For installation waste, to be carried out by the architect/ main contractor/ flooring contractor. Ensures CO2 savings.

Sustainability data

Contains Red List materials

No

Country of product manufacture

Sweden

Embodied carbon

A1-A3 (production stage) as defined in BS EN 15804

6.02 kg CO₂ eq/m²

Self declared

Recyclability

100%

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

25.5 %