Verified by manufacturer 5 days ago
35 dB Rw | 10 mm Toughened Glass
EPD
Certificate type
Single glazed partition system with a 100 mm wide frame and with extruded LOFT transoms and/ or mullions.
All sectors: Commercial: Education; Healthcare; MoD; Airport; Rail; Industrial; Hospitality; Residential; Public.
Consult manufacturer for further details.
Single glazed partition system with a 100 mm wide frame and with extruded LOFT transoms and/ or mullions.
Features and benefits:
Please note that acoustic, fire rated and structural certification and support for Planet products and systems is available on a project-specific basis. Please contact the specification team directly for further information.
Color | Other Guidance for specification option: Polyester powder-coated or anodized. Silver Guidance for specification option: Polished and linished. |
Finish | Anodized Guidance for specification option: Etched and anodized. Polished Powder-coated |
Material | Aluminium Guidance for specification option: 6063 T6. Glass |
Shape | Manufacturer guidanceTo suit project requirements; consult manufacturer for further details. |
Length | Bespoke |
Width | 100 mm |
Height | Bespoke |
Warranty description | Manufacturer guidanceDealt with on a project specific basis as part of the O&M process; consult manufacturer for details. |
Uniclass | |
CAWS | K30/130 Relocatable partition system K30/10 Relocatable partition system |
Product range |
Third-party certification | ISO 9001-UKAS (Quality); ISO 14001-UKAS (Environmental); Constructionline-Gold; Acclaim (SIPP); Achilles (Building confidence, SIPP); EPD - material accreditation & compliance; FIS Member; Considerate Construction; FORS Bronze; Build Profile.Guidance for specification option: EPD - material accreditation & compliance: Consult manufacturer for details (glass, PPC, aluminium, timber, ironmongery, waste, adhesive and more). |
Unit size | |
Thickness | 100 mm. |
Partition height (nominal) | Manufacturer guidanceInsert requirements. For partitions over 3000 mm high, consult with manufacturer. |
Width (nominal) | Manufacturer guidanceInsert requirements. For partitions over 1200 mm wide, consult with manufacturer. |
Deflection allowance (maximum) | |
Head | No deflection; 27 mm-deep x 100 mm-wide channel.±15 mm deflection; 60 mm-deep x 100 mm-wide channel.±25 mm deflection; 90 mm-deep x 100 mm-wide channel.±40 mm deflection; 146 mm-deep x 100 mm-wide channel. |
Floor | Manufacturer guidanceConsult with manufacturer for system weight. |
Verticals | 27 mm-deep x 100 mm-wide channel. |
Panel partition type | Framed glass - single offset glazed - with extruded LOFT transoms and/or mullion profiles. |
Framing, fixing points and joints | 27 mm-deep x 100 mm-wide base/ abutment tracks.Guidance for specification option: Corners: glass-to-glass joints. |
Solid panels | |
Type | Not required.Back painted glass.Steel faced boards.Veneered panels.Magnetic white board film. |
Finish and colour | Not applicable.To match frame.Polyester powder-coated, RAL.Guidance for specification option: Insert colour requirement. Polished and chemically brightened.Linished and chemically brightened.Etched and anodized.Guidance for specification option: Insert requirement. Timber veneer type, finish and matching.Guidance for specification option: Insert requirement. |
Joint treatment | |
Type | Mullion, transom: 27 mm-deep x 100 mm-wide extruded profile. Corners: 100 x 100 mm corner box with abutment tracks. |
Finish and colour | Polyester powder-coated, RAL.Guidance for specification option: Insert colour requirement. Polished and chemically brightened.Linished and chemically brightened.Etched and anodized.Guidance for specification option: Insert requirement. |
Glazed panels | |
Type | Offset-single, 10 mm toughened glass.Guidance for specification option: Additional manufacturer options;
Consult manufacturer for details. Manufacturer guidanceConsult manufacturer to ensure compliance with test/ assessment data. |
Integral blinds | n/a.Guidance for specification option: Not suitable for this system. |
Additional features | None.Double glazed/ boarded tech panel to incorporate room booking systems, access control and other electronics. |
Door arrangement | |
Type | IsoTec micro framed leaf in door frame, single leaf, single action.IsoTec micro framed leaf in door frame, unequal leaves, single action.IsoTec micro framed leaf in door frame, double leaves, single action.IsoPro framed leaf in door frame, single leaf, single action.IsoPro framed leaf in door frame, unequal leaves, single action.IsoPro framed leaf in door frame, double leaves, single action. |
Door frames | Planet A131 aluminium door frame, with single leaf set.Planet A131 aluminium door frame, with unequal leaf doors.Planet A131 aluminium door frame, with double doors. |
Door panels | |
Type | Planet IsoTec 12 mm door leaf – non-acoustic.Guidance for specification option: Suitable for use in:
Planet IsoTec 12 mm door leaf – 34 dB Rw.Guidance for specification option: Suitable for use in Planet aluminium door frame, with single leaf set only. Planet IsoPro, single glazed metal framed door leaf – 34 dB Rw.Guidance for specification option: Suitable for use in Planet aluminium door frame, with single leaf set only. Planet IsoPro, double glazed metal framed door leaf – 34 dB Rw.Guidance for specification option: Suitable for use in Planet aluminium door frame, with single leaf set only. Planet IsoPro, single glazed metal framed door leaf – 36 dB Rw.Guidance for specification option: Suitable for use in Planet aluminium door frame, with single leaf set only. Planet IsoPro, double glazed metal framed door leaf – 39 dB Rw.Guidance for specification option: Suitable for use in Planet aluminium door frame, with single leaf set only. Planet IsoPro, double glazed metal framed door leaf – 42 dB Rw.Guidance for specification option: Suitable for use in Planet aluminium door frame, with single leaf set only. Timber 44 mm leaf on hinges – 29 dB on to carpet.Guidance for specification option: Suitable for use in Planet aluminium door frame, with single leaf set only. Timber 44 mm leaf on hinges – 32 dB on to carpet.Guidance for specification option: Suitable for use in Planet aluminium door frame, with single leaf set only. Timber 54 mm rebated leaf on hinges – 33 dB on to carpet.Guidance for specification option: Suitable for use in Planet aluminium door frame, with single leaf set only. Timber 54 mm rebated leaf on hinges – 38 dB on to solid floor.Guidance for specification option: Suitable for use in Planet aluminium door frame, with single leaf set only. Timber 54 mm rebated leaf on hinges – 40 dB on to aluminium threshold.Guidance for specification option: Suitable for use in Planet aluminium door frame, with single leaf set only. Planet IsoPro, double glazed metal framed door leaf (non-rebated) – 31 dB Rw.Guidance for specification option: Suitable for use in:
Planet IsoPro, double glazed metal framed door leaf (rebated) – 33 dB.Guidance for specification option: Suitable for use in Planet aluminium door frame, with unequal leaf doorset only. Planet IsoPro, double glazed metal framed door leaf (rebated) – 35 dB.Guidance for specification option: Suitable for use in Planet aluminium door frame, with unequal leaf doorset only. Planet IsoPro, double glazed metal framed door leaf (rebated) – 36 dB.Guidance for specification option: Suitable for use in Planet aluminium door frame, with unequal leaf doorset only. Planet IsoPro, single glazed metal framed door leaf (non-rebated) – non-acoustic.Guidance for specification option: Suitable for use in Planet aluminium door frame, with double leaf doorset only. Timber 44 mm leaf on hinges – non-acoustic.Guidance for specification option: Suitable for use in Planet aluminium door frame, with double leaf doorset only. Timber 54 mm rebated leaf on hinges – non-acoustic.Guidance for specification option: Suitable for use in Planet aluminium door frame, with double leaf doorset only. |
Vision panels | Not required.Required.Guidance for specification option: Available with timber door leaves only; consult manufacturer for details and insert requirements. |
Ceiling | |
Type | Manufacturer guidanceConsult manufacturer for interface detail and insert requirements. |
Method of support | Manufacturer guidanceConsult manufacturer for support detail and insert requirements. |
Perimeters, skirtings, sills | 27 mm-deep x 100 mm-wide aluminium channel. |
Trims | Mullion, transom: 27 mm-deep x 100 mm-wide extruded profile. |
Hardware | Manufacturer guidanceSee appropriate door specification for applicable ironmongery options and insert requirements. |
Seals | Clear perimeter compression seals.Black perimeter compression seals. |
Cable management and outlets | Not required.As Glazed panels - Additional features.Guidance for specification option: Double glazed/ boarded Tech Panel to incorporate room booking systems, access control and other electronics. |
Other features | Manufacturer guidanceConsult manufacturer and insert requirements or leave blank. |
Product Reference | LOFT100 Offset Single Glazed Panel Partition System (True) |
Manifestation | Allowance of 2 nr rows 50 mm dots or square (minimum) Opal Frost. Guidance for specification option: Insert requirements. Artwork and custom manifestation to client design. Guidance for specification option: Insert requirements. Manufacturer guidanceTo architects choice and in accordance with the requirements of Approved Document K. |
StrengthGrade | Manufacturer guidanceConsult with the manufacturer to ensure the system complies with current regulations BS 5234:1992 non load-bearing screens not protecting a change in adjacent floor level of >380 mm. For glass load resistance criteria;
Building regulations Part N (BS 6262 & BS EN 12600) + InsStucEng publication “structural use of glass in buildings” insert as required:
BS 6180:2011 barriers in and about buildings for Atria or protected change in adjacent floor level of >380 mm. Horizontal uniformly distributed line load 1100 mm above FFL (glass deflection limited to L/65 or 25 mm, whichever is less relative to glass fixings). Structural glass based on line-load and attendant UDL + point load, insert as required:
|
Acoustic performance | 35 dB Rw. Manufacturer guidanceTo comply to EN ISO 10140-2 and ISO 717-1: Acoustics vary according to framework/glazing options subject to further design development. |
Partition | Framed glass - single offset glazed - with extruded LOFT transoms and/ or mullions. |
Fasteners | To manufacturer's specification, type, length and frequency to suit substrates. |
Joint treatment | 27 mm-tall LOFT mullion and/ or transom. |
Finish/ Colour | Polyester powder-coated, RAL. Guidance for specification option: Insert colour requirement. Polished and chemically brightened. Linished and chemically brightened. Etched and anodized. Guidance for specification option: Insert requirement. |
System accessories | Manufacturer guidanceTech panels, access control - consult with manufacturer for details. |
Samples required | Manufacturer guidanceConsult with manufacturer. |
Contains Red List materials | No Guidance for specification option: No substance on the “Candidate List of Substances of Very High Concern for authorisation” derived under REACH is present either above the limits for registration with the European Chemicals Agency or in excess of 1 weight–% of the product. |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Material | Aluminium Guidance for specification option: 6063 T6. Glass |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | 82.3 kg CO₂ eq/m² Guidance for specification option: There will be slight variances in embodied carbon if different glass thicknesses, etc, are used. These embodied carbon figures are for 1 m² of each type of partition – modules A1-A3 including biogenic carbon. The EPD for the single glazed partition systems is based on powder-coated aluminium-framed single-glazed partition systems using 12.8 mm laminated glass, without a door. |
Recyclability | 100% Guidance for specification option: Aluminium and glass. |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | Manufacturer guidance17–28% for glass. 70% for aluminium. |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 2 | |
- | 1 |
FireClear100 Double Glazed Fire Rated Partition System
FireClear20 Single Glazed Fire Rated Partition System
FireClear54 Double Glazed Fire Rated Partition System
FireEco Ei30 Double Glazed Fire Rated Partition System
FireEco Ei30 Single Glazed Fire Rated Partition System
FireEco Ei60 Double Glazed Fire Rated Partition System
FireEco Ei60 Single Glazed Fire Rated Partition System
FirePro E120 Single Glazed Partition System And Ei 60 Doorset
FirePro E30 Double Glazed Partition System And Doorset
FirePro E30 Single Glazed Partition System and Doorset