NBS Source
I'm a manufacturer
Compare variants

Masonry Reinforcement SBS30W60

Verified by manufacturer 7 days ago

Galvanized

Tec Ties Ltd Variant:
Third party certifications:
  • ISO 9001 Quality Management

    Certificate type

  • DoP

    DoP

    Certificate type

Bed joint reinforcement for strengthening masonry walls.

Jump to:
+44 (0)1663 749361 Website

Application

  • For structural use within walls and partitions.
  • Stainless steel can be used on both inner and external bricks or blocks.
  • Galvanized is suited to internal walls.

Description

MSF Masonry Reinforcement, also known as brickspan, or bed joint reinforcement is primarily used to strengthen walls. Stainless steel can be used on both inner and external bricks/blocks whereas galvanized is more suited to internal walls. The masonry reinforcement aids to reduce cracking and provide general support.


The reinforcement comes at a standard length of 2.7 metres, and is available in a range of wire diameters making the range versatile, and able to fit any combination of brick or block width. Available in both stainless and galvanized, including 3.0 mm, 3.5 mm, 4.0 mm and 5.0 mm (or equivalent after being flattened). Usually packed and shipped in packs of either 40 lengths, or 20 lengths (depending on the weight and size of the reinforcement), however, orders are not tied to these figures, and any amount can be ordered.


Features and benefits:

  • 2700 mm lengths reduce the required amount of laps.
  • Lengths can be supplied in any required width or amount, regardless of pack quantity.
  • A 20 mm cover on each side, allowing for site tolerance (with code stating a minimum of 15 mm).
  • In addition to the stock sizes, widths can be manufactured to suit any block or brick size.
  • Special shapes including ‘T’ sections and corner pieces can also be manufactured.

General information

Color

Silver

Material

Stainless steel

Steel

Shape

Rectangle

Length

2700 mm

Width

175 mm

150 mm

100 mm

60 mm

Uniclass

Pr_20_96_71_83 Stainless steel bed joint reinforcementPrimary
Pr_20_96_71_10 Carbon steel bed joint reinforcement

CAWS

F30/43 Meshwork joint reinforcement

F30/270 Meshwork joint reinforcement

Specification data - Stainless steel bed joint reinforcement

Standard

To BS EN 845-3.

Configuration of bed joint reinforcement

Welded wire ladder.

Dimensions

-

Wire size

3 mm.

3.5 mm.

4.0 mm.

5.0 mm.

Ladder or truss width (overall)

60 mm.

Guidance for specification option:

For 102 mm brick, 100 mm or 125 mm blockwork.

100 mm.

Guidance for specification option:

For 140 mm or 150 mm blockwork.

150 mm.

Guidance for specification option:

For 190 mm or 200 mm blockwork.

175 mm.

Guidance for specification option:

For 215 mm blockwork.

Reinforcement material

Galvanized steel.

Yield strength

S00 N/mm².

Manufacturer guidance

Characteristic yield strength of longitudinal wires.

Bond strength

5990 N.

TensileStrength

15% Greater than yield stress.

Sustainability data

Contains Red List materials

No

Country of product manufacture

United Kingdom

Material

Stainless steel

Steel

Recyclability

100%

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

0 %

Third party certifications

ISO 9001 Quality Management

ISO 9001 Quality Management

ISO 9001 :2015

DoP

DoP

Tecties DOP SBS30W60

Literature

Masonry reinforcement ladder rack 30w60

Masonry reinforcement ladder rack 30w60