Verified by manufacturer over a year ago
Max Compact Interior F-Quality Single Sided
High-pressure laminate panel for interior use.
Suitable for interior use including wall cladding, railing infill panels, furniture, tables, desks, column cladding and lab equipment etc. Typical application in wet and sanitary rooms and areas where heavy duty use occurs.
FunderMax Compact are high-pressure laminate (HPL) double-sided panels for interior use.
Features and benefits:
Shape | Rectangle |
Color | Manufacturer guidancePanel core is black with laminate finish applied to each side. |
Finish | Matt Embossed |
Material | Laminate Guidance for specification option: High-pressure laminate panels (HPL) according to EN 438-4. |
Size | 2140 x 1060 mm 2140 x 1060 mm 4100 x 1854 mm 2800 x 1300 mm 2800 x 1854 mm |
Uniclass | |
CAWS | K13/140 Proprietary laminated plastics-veneered panel lining K13/145 Proprietary plastics cladding Q40/30 Proprietary fencing Q40/430 Proprietary fencing |
Grade | HPL/ EN 438-4/ CGS. |
Fire rating | Manufacturer guidanceTo EN 13501-1: Euroclass B - s2, d0 for 4-20 mm, Euroclass B - s1, d0 for 6-20 mm if mounted with a maximum gap of 15 mm B1 “schwer entflammbar” according to DIN 4102-1. |
Thickness | 2–20 mmGuidance for specification option: 2–20 mm except 2800 x 1854 mm only 2–15 mm. (2–4 mm single sided). |
Panel size | |
Length | 2140 mm.2800 mm.4100 mm. |
Width | 1060 mm.1300 mm.1854 mm. |
Edges | Non-bevelled cut edges as standard.Guidance for specification option: Edge processing is possible. |
Finish | Fine hammer embossed.Guidance for specification option: Fine hammer embossed (top side), Melamine sanded (reverse side). Matt.Guidance for specification option: Matt (top side), Melamine sanded (reverse side). |
Colour | Black.Guidance for specification option: (core), surfaces are available in a wide range of decors, see manufacturer's literature for details. |
Specials | Not required.Fine hammer embossed or matt (surface). |
Apparent density | DIN 52350/ EN ISO 1183 ≥1.35 g/cm³. |
Flexural strength to EN ISO 178 | ≥80 MPa. |
E-Modulus to EN ISO 178 | ≥9000 MPa. |
Coefficient of thermal expansion to EN 61340-4-1 | 20 x 10^-6 1/K. |
ThermalConductivity | 0.3 W/mK. |
Water vapour diffusion resistance | 17.200 μ. |
Resistance against stress abrasion to EN 438-2 | ≥150 U. |
Resistance against scratching to EN 438-2 | ≥3 Degree (4 N). |
Susceptibility to cracking to EN 438-2 | ≥4. |
Light fastness to EN 438-2 | ≥4. |
Fixing | Guidance for specification option: A variety of options for fixing exist, including mechanical fastening, consult the manufacturer for details and insert requirements. |
Contains Red List materials | Manufacturer guidanceThe panels do not contain organic halogens (or chlorine, fluorine, bromine, etc.) compounds such as are found in greenhouse gases or PVC. They contain neither asbestos nor wood protection agents (fungicides, pesticides,etc.) and are free of sulfur, mercury and cadmium. |
Country of material origin | Austria |
Recyclability | Manufacturer guidanceMade from 65% natural fibre panels. Production waste is used to generate energy in Fundermax's green energy district heating plants. |