200 kVA
Three-phase distribution pre-fabricated substation.
Outdoor 12 kV MV-LV Substation.
Performance up to 12 kV: 200 kVA to 2000 kVA.
Three-phase distribution pre-fabricated substation.
Features and benefits:
Color | Grey Other |
Finish | Painted Powder-coated |
Material | Stainless steel |
Shape | Rectangle |
Length | 2850 mm 3000 mm 3800 mm 3750 mm |
Width | 1700 mm 2000 mm 2400 mm 2800 mm Manufacturer guidanceDepth. |
Height | 2100 mm |
Warranty description | 18 months |
Uniclass |
Classification data | |
Description | Metalclad distribution substation. |
System performance | To IEC 62271-202. |
Transformers | Distribution transformers. Guidance for specification option: Distribution transformers: A standard range of distribution transformers rated 200, 315, 500, 800, 1000, 1250, 1500 or 1600 kVA. |
High-voltage (HV) switchgear | Schneider Electric medium voltage range switchgear. Guidance for specification option: Schneider Electric range switchgear: RN2d ring main unit, Ringmaster range CN2 circuit breaker or SN6 switch disconnector. |
Low-voltage (LV) switchgear | Schneider Electric low voltage NS feeder pillar. Guidance for specification option: Schneider Electric low voltage NS feeder pillar: Outgoing LV ways to suit connected loads, utilizing the latest Masterpact MTZ ACB and Compact NSX MCCB or SAIF/Shielded Fusegear, utilizing Schneider Electric’s fusegear technology. |
Accessories | Not required. Remote terminal unit. AC/ DC convertors. Power factor correction equipment. Harmonic control. Remote monitoring. Transformer liquid temperature indicator. High fire point fluid (Midel 7131). |
Configuration | Adjacent sides substation arrangement. Guidance for specification option: HV and LV flanges on adjacent sides of transformer tank. In-line substation arrangement. Guidance for specification option: HV and LV flanges on opposite narrow end of tank – “in line”. Unit substation arrangement. Guidance for specification option: HV and LV flanges on same side of transformer tank. Manufacturer guidanceDependent upon substation configuration, the substation has one/ two/ three access doors to the HV and LV compartments which are held by two-point latching (top and bottom). The latching handle is padlockable and covered by a hinged flap which is also padlockable. In addition to the front doors, the enclosure has side doors which are designed to hinge outwards during installation to ensure good access for cable jointers. After installation, the side doors are held closed by internal bolts. Access for operation, maintenance and the connection of additional LV cables is from the front doors only. |
Tank type | Free-breathing. Hermetically sealed. |
Power | Up to 12 kV. |
ApparentPower | 200 kVA. |
Overall sound power level | 52 dB(A). |
Load | Load loss: 2015 W. No load loss: 225 W. |
Frequency | 50 Hz. |
Ingress protection (IP) rating | IP54. Guidance for specification option:
|
Enclosure | Integral corrosion resistant stainless steel enclosure. Guidance for specification option: Enclosure: An integral corrosion resistant stainless steel enclosure, polyester powder coated. |
Colour | Dark Grey. Guidance for specification option: Colour ref 632 or BS 381C. Other. Manufacturer guidanceTo ISO 12944, Category C4 Very High Durability paint. |
Ventilation | Ventilation mesh/ grill. Ventilation louvres. |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Manufacturing plant location | |
Material | Stainless steel |
Expected Life | 20 year |