Verified by manufacturer 2 days ago
EPD
Certificate type
High ductility, fibre-reinforced thixotropic mortar for concrete and masonry reconstruction.
Suitable for use in non-structural repair applications on stone, brick and concrete. Levelling of reinforced concrete and blockwork surfaces, prior to tiling.
Metric R2 Fix is an EN 1504 class R2 mortar for repairing and levelling concrete structures and anti-cracking interventions.
Features and benefits:
Color | Grey |
Finish | Unfinished |
Material | Cement Fibre cement Polymer-modified cement |
Shape | Formless |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Uniclass | |
CAWS | C41/610 Mortar repair of cracks C42/315 Protective coating to reinforcement C42/310 Repair mortar |
Classification data | |
Standard | To BS EN 1504-3. |
Mortar type | Fibre-reinforced thixotropic. |
Performance requirement class | R2. |
Mass | 1340 kg/m³. Guidance for specification option: Apparent volumetric mass. |
Aggregate | Silicate - carbonate. |
Grading category | To EN 12192-1, 0–0.5 mm. |
Density | 1750 kg/m³. |
Application temperature range | +5°C to +35°C. |
Reaction to fire | Class A1. |
Typical compressive strength | ≥15 N/mm². |
Chloride Ion content | ≤0.05%. |
Adhesion | To EN 1504-3, >2 N/mm² |
Capillary absorption | ≤0.5 kg/m²/√h. |
Freeze/ Thaw Resistance | ≥0.8 MPa. |
Country of product manufacture | Italy |
Material | Cement Fibre cement Polymer-modified cement |
Carbon dioxide equivalent | |
Carbon dioxide equivalent, as defined in BS EN 15804 Certified | |
Stage Normalised unit (kg CO₂ eq/kg) Declared unit (kg CO₂ eq/kg) Stage:A1–A3 ('Production stage') Normalised unit 0.268 (kg CO₂ eq/kg) : Declared unit 0.268 : Lower emissions | |
Recyclability | Recyclable |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 25 % |