Verified by manufacturer 3 months ago
50 mm.
BBA Agrément Certificate
Certificate type
Low lambda non-combustible stone wool insulation for ventilated facades.
NyRock® Rainscreen 032 is a stone wool insulation product specifically developed for use within ventilated cladding systems, as well as sealed systems such as curtain walling.
Manufactured using patented technology, NyRock Rainscreen 032 has a more efficient fibre structure that increases the density of air pockets trapped within each slab. This results in an improved thermal performance when compared to traditional stone wool products.
Once installed, the product’s high density works in combination with a factory applied water repelling agent to give improved resistance to rain ingress during construction.
The product can be fitted around brackets and other awkward details, and when tightly butted, adjacent slabs effectively ‘knit’ together to provide a continuous insulating layer, reducing heat losses that would otherwise be caused by gaps.
For optimum thermal performance in framed structures, combine NyRock Rainscreen Slab 032 with NyRock Frame Slab 032.
Features and benefits:
For use on steel frame, timber frame, or masonry walls in
conjunction rainscreen cladding:
For use on steel frame or timber frame with a brick outer leaf:
Color | Yellow |
Material | Stonewool |
Shape | Rectangle |
Length | 1200 mm |
Width | 600 mm |
Height | 50 mm 55 mm 60 mm 65 mm 70 mm |
Uniclass | |
CAWS | H92/776 Thermal insulation P10/217 Insulation slabs fixed to backing wall H11/110 Curtain walling H11/780 Thermal insulation P10/42 Mineral wool insulation slabs fixed to backing wall |
Standard | To EN 13501-1, BS EN 13162. |
Thickness | 50 mm.Manufacturer guidanceConsult manufacturer's literature for example U-values based on various cladding systems, with or without NyRock Frame Slab 032. |
Edges | Square. |
Density | Manufacturer's standard. |
Thermal conductivity (maximum) | 0.032 W/m·K. |
Compressive strength (minimum) | Manufacturer's standard. |
Fire performance | To BS EN 13501-1, A1. |
Sound insulation rating | Manufacturer's standard.Guidance for specification option: Consult manufacturer's literature for details. |
Vapour resistivity | 5.9 MNs/gm. |
Cavity barriers | Manufacturer guidanceInsert requirements. Manufacturer recommends the use of SP Firestop vertically and SP Firestop or SP Firestop OSCB horizontally, depending on outer leaf. Consult manufacturer's literature for details. |
Fixing | Manufacturer guidanceTo be secured to the substrate with metal and polypropylene fixings; consult manufacturer's literature for details and insert requirements. Horizontal joints should be staggered and all joints tight butted. |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Recyclability | Can be recycled |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 1 | |
- | 1 |
FirePro® Ablative Coated Batt - Stone wool with ablative coating
Flexi®
HardRock® Multi-Fix (DD)
HardRock® UB34 - Insulation
NyRock® Cavity Slab 032 - Masonry Cavity Wall Insulation
NyRock® Frame Slab 032 - Insulation
RainScreen Duo Slab®
ROCKWOOL® Acoustic Infills
ROCKWOOL® HP Partial Fill Cavity Slabs - Insulation
ROCKWOOL® Insulation Slabs – RWA45, RW3, RW4 and RW5