Structureseal GPT is a pre-applied, unique blended polyethylene membrane with a bonded geotextile for pre-applied waterproofing applications, where ground gas or VOC protection is also required.
The product is pre-applied for use in basements and sub-structures, floor slabs at ground level, boundary line applications and retaining walls. Can be applied to:
Pre-applied, Type A tanking membrane, suitable for use where protection against the ingress of hazardous ground gases, volatile organic compounds (VOCs) and hydrocarbons is required.
Features and benefits:
Color | Grey |
Finish | Textured Other Smooth |
Material | Other Polyethylene |
Shape | Rectangle Other |
Length | 25000 mm |
Width | 1900 mm |
Height | 1.5 mm |
Warranty description | Ten year |
Uniclass | |
CAWS | J40/140 Loose-laid plastics or rubber sheet gas-retardant membranes J40/145 Loose-laid weldable polyethylene gas-retardant membranes J40/35 Loose-laid plastics or rubber gas-retardant membranes |
Material | Ethylene-vinyl alcohol copolymer (EVOH). |
Purpose | Gas retardance.Water resistance. |
Performance characteristics | |
Tensile strength (minimum) | >550 N/50 mm / >400 N/50 mm.Guidance for specification option: Machine direction (MD) / Cross machine direction (CD) Manufacturer guidanceTo EN 12310-1 |
Tear resistance | 300 N / 400 N.Guidance for specification option: Machine direction (MD) / Cross machine direction (CD) Manufacturer guidanceTo EN 12310-1 |
Resistant to underground gases | Carbon dioxide.Guidance for specification option: Carbon dioxide permeability (to BS EN ISO 15105-1): 3.01 ml/m²/day/atm. Methane.Guidance for specification option: Methane gas permeability (to BS EN ISO 15105-1): 0.13 ml/m²/day/atm. Radon.Guidance for specification option: Radon permeability (SP Method 3873): 3 x 10-12m².s. Hydrocarbons.VOC. |
Physical properties | |
Colour | Grey. |
Weight (minimum) | Guidance for specification option: 33 kg per roll. |
Dimensions | |
Thickness (minimum) | 1.5 mm. |
Width (minimum) | 1.9 m. |
Roll length (minimum) | 25 m. |
Sealed Laps | Adjacent laps (welded or taped), 100 mm wide (onto selvedge). |
Water vapour transmission | To BS EN 1931, 0.14 g/m²/day. |