Application

Suitable for use in shingle cladding applications.

Description

Roofinox® Stainless Steel Shingles for use in Fully Supported Facade Applications. Shingle cladding (also referred to as flat lock or single lock cladding) can be installed in horizontal and vertical panel systems or using small shaped tiles.

The shingles can be square, rectangular, rhomboid, triangular or bespoke shapes and are popular in providing designers with a choice of finishes and patterns using traditional metals. Shingles have folded hems approximately 25 mm wide, fixed to the substrate using cleats or clips. Due to the flexibility of the system and the many alternative shapes and sizes the designer has a wide choice of options.

General information

Color

Black

Bronze

Gold

Other

Finish

Coated

Matt

Material

Stainless steel

Length

Bespoke

Width

Bespoke

Height

Bespoke

Warranty description

60 year

Uniclass

Ss_25_20_50_85 Stainless steel sheet fully supported wall-covering systemsPrimary

CAWS

H75/150 Stainless steel fully supported covering to dormers

H75/130 Stainless steel fully supported wall covering

H75/5 Stainless steel sheet fully supported covering to dormers

Specification data - Stainless steel sheet fully supported wall-covering systems

Classification data

Membrane

Breather membrane.

Manufacturer guidance

The breather membrane must comply with EN 13859-1 for roofs and must also be CE compliant.

The breather membrane must be fully supported, lapped and sealed and then further sealed to all surrounding abutments and surface penetrations.

Insulation

-

Manufacturer guidance

Shingle cladding does not have any specific requirement with regard to the insulation. Insulation must be structurally self-supporting or supported when installed so that it will not sag and form unvented voids or cause loss of thermal efficiency. An insulation used as a directly supporting substrate must have a minimum compression strength of 50 kPa (0.5 kg/cm²) with deformation limited to a maximum of 10%. The insulation must also be dimensionally stable up to 100°C. All insulation must be kept dry and protected prior to metal covering being laid.

Air and vapour control layer

Alutrix 600 / Metal Shield

Guidance for specification option:

A compatible Primer to be used on porous substrates.

Some manufacturer's recommendations for warm cladding or roof constructions require a minimum of 5 screw fixings per M2 through the VB, therefore this type of VB must have the properties of self-sealing around screw fixings when penetrated. In this instance, it is accepted that a VB with an aluminium foil face and a polymer bitumen core and self-adhesive properties offers the best performance. Alutrix & Metal Shield comply with this requirement.

Manufacturer guidance

Vapour Barrier membranes must comply with EN 13859-1 for walls or roofs and must also be CE compliant.

For fully supported metal cladding or roofs, the VB must have a minimum water vapour resistance of 4000MNs/g and comply to BS SO 12572. The VB must have a resistance against a supported column of water 2M high for a period of 15 mins to comply with DIN EN 20811.

All cladding or roofs must have a Vapour Barrier regardless of being ventilated, unventilated cold or warm in design. The VB must be positioned behind/ below the insulation and on the warm side of the construction.

Carrier

As design.

Substrate

18 mm plywood exterior grade.

Guidance for specification option:

The European Standard is EN 636-3 - for use in exterior conditions including liquid, water or water vapour in damp but ventilated locations. Service Class 3 in Euro Code 5 covers plywood to be used in climate conditions leading to a higher moisture content than in service class 2.

The minimum board thickness must be 18 mm (or layers of thinner boards that combine to achieve the minimum 18 mm thickness for curved coverings). The plywood face laminate must be free of knots and defects and should as a minimum be "good one side". Shuttering ply is not suitable.

18 mm OSB-3 or better (oriented strand board).

Guidance for specification option:

Also known as sterling board, has been developed over the past 20 years and is formed by layered flakes of wood in specific orientation. Its wooden strips are compressed and bonded together with wax and resin adhesive.

It is comparatively cost effective and therefore has been increasingly used as a substrate for cladding or roofing systems. However, care must be exercised when used as a substrate under traditional metal cladding or roofing and should be protected from moisture during construction. It is advised that screw fixings are used to ensure good pull-out values.

24 mm timber or sarking board decking.

Guidance for specification option:

It complies with 8S5268: Part 2 (strength class SC3), or EN 1611-1:1999 (sawn timber normally with a maximum moisture content of 22%). There are some woods which are not compatible with cladding or roofing metals, due to high acid content.

UK recommended practice is a range of 18 mm to 25 mm thickness, in widths of 100 mm to 125 mm and laid with 3–5 mm gaps between the boards parallel to the eaves. In some cases, because of the nature of the building's structure, a diagonal boarding layout is used.

It is particularly important to note that timber protectives, preservatives and adhesives used in plywood board construction can react with the cladding or roofing metal and if applicable, suitable separation layers must be used.

Rigid insulation.

Guidance for specification option:

Insulation must be structurally self-supporting or supported when installed so that it will not sag and form unvented voids or cause loss of thermal efficiency. An insulation used as a directly supporting substrate must have a minimum compression strength of 50 kPa (0.5 kg/cm²) with deformation limited to a maximum of 10%. The insulation must also be dimensionally stable up to 100C. Warm cladding or roof fixings including stainless toothed plate and sliding clip, plastic peg and fixing screws are used in conjunction with an insulated deck.

Composite panel.

Guidance for specification option:

The composite panel is constructed from factory produced interlocking steel or aluminium panels, encasing an insulation core (PIR or other). The panels are laid across the wall or roof supporting rafters or rails.

The interlocking joints must be sealed with gaskets or sealant and taped according to the manufacturer's recommendations, with sealed metal closures to hips ridges, verges, eaves and penetrations. The total area and abutments must be sealed airtight. 0.7 mm thick outer face is recommended. This type of construction gives a good vapour sealed substrate and can be quickly constructed.

Non-combustibles.

Guidance for specification option:

Alternative non-combustible supporting substrates, such as metal profiled sheets and fire rated sheathing boards are now commonplace due to changes in building regulations. These are a direct substitute for plywood or similar and should be evaluated based on their pull-out values. When a metal profiled sheet is used, fixings must be rivets or self-drilling screws.

Cavity barriers

-

Horizontal

To BS 9991.

Vertical

To BS 9991.

Sheet underlay

-

Material

ISO-Mat Pro® underlay.

Guidance for specification option:

The underlay is recommended for cold vented substrate applications.

Envirotect Class B-s1,d0 fire membrane.

Guidance for specification option:

Can be used when a non-combustible option is required.

Stainless steel

0.4/ 0.5 mm thick stainless Steel 316L (1.4401) → Austenitic, ~16–18% Cr, ~10–12% Ni, plus ~2% Mo (for extra corrosion resistance).

Vertical joints

-

Form

Single lock cross welt 18 mm.

Fasteners to substrate

Timber - stainless screw, SPT-R-S-4.3x20-RS.
Timber - annular ringshank nail, RSN-SS25.
Timber - Paslode IM45 25 mm Nail - 142201.
Metal - stainless screw, SX2-D9-4.8x22.
Metal - stainless screw, DS3-SS-SF-4.8x16.

System accessories

Flat Lock Clips

Guidance for specification option:

30 mm clips – RFLC-30 – breather membrane

Manufacturer guidance

All associated flashings to match can be fabricated from coil by Metal Solutions Ltd as per typical details and industry standards.

Associated rainwater goods in various sizes and profiles are available in the same material. Consult manufacturer for details and insert requirements.

System completion

Operation and maintenance manual

Colour/ Finish:

Classic.

Guidance for specification option:

Standard finish.

Classic (commonly used in wall applications and rainwater goods only).

Tin matte.

Guidance for specification option:

Standard finish.

Tin matte (commonly used for roofing applications only).

Chroma.
Dura Black.
Dura Bronze.
Dura Champagne.
Dura Rose-Gold.
Pearl.
Plasma.
Plus Matte.
Proton.
Spectra Sedona.
Spectra Vulcano.
Spectra Vulcano Plus.

Size and profile

-

Manufacturer guidance

Optimised shingle sizes will be based from available coil widths (although some colours will vary):

Typical sizes will be 530 x 530 mm, 430 x 430 mm and 230 x 230 mm visible face. All other sizes are available.

Consult manufacturer and insert requirements.

Weight

0.5 mm material weight 4 kg/m².

Guidance for specification option:

System weight dependent on seam centres.

Fire classification

Reaction to fire: A1 To EN 13501-5.
External Fire Performance: Class BROOF (t1).

Sustainability data

Contains Red List materials

No

Country of material origin

Austria

Country of product manufacture

United Kingdom

Material

Stainless steel
Carbon dioxide equivalent

Carbon dioxide equivalent, as defined in BS EN 15804

Self-declared

Stage
Normalised unit (kg CO₂ eq/kg)
Declared unit (kg CO₂ eq/kg)
Stage:A1–A3 ('Production stage')
Normalised unit : 1.7 (kg CO₂ eq/kg)
Declared unit : 1.7

Recyclability

100%

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

95 %

Expected Life

100 year

Literature

Metal Solutions Limted - Shingles Leaflet

Metal Solutions Limted - Shingles Leaflet

Metal Solutions Shingle System

Metal Solutions Shingle System

Similar products from Metal Solutions Limited

Roofinox Stainless Steel Snaplock® Seam Cladding

Roofinox® Stainless Steel Standing Seam Facade Cladding