Verified by manufacturer 5 days ago
RP50SS
Constructionline
Certificate type
ISO 9001 Quality Management
Certificate type
Acclaim Accreditation
Certificate type
Range of roof penetration fittings used for cables and pipes, providing a safe routing solution to the internal environment.
Suitable for the following roof types:
Compatible with the following roof weathering materials:
Can be used for:
Roof penetration fittings with an upstand and removable weathering hood. The top of the upstand has a gasket to protect the services as they exit the upstand. Can be used to provide entry/ exit for cables and services through the weathering layer.
50 mm version available for smaller cables and pipes, and 110 and 150 mm versions for larger cables and pipes.
Features and benefits:
Color | Silver Grey |
Finish | Powder-coated |
Material | Stainless steel Aluminium EPDM Bitumen Guidance for specification option: SBS-modified bitumen. Styrene butadiene |
Shape | Other |
Length | 150 mm Guidance for specification option: RP150. 300 mm Guidance for specification option: SS. Fixing plate. 400 mm Guidance for specification option: SP. PVC sheet. Fixing plate: 230 mm. 500 mm Guidance for specification option: SBS. Bitumen sheet. Fixing plate: 230 mm. |
Width | 150 mm Guidance for specification option: RP150. 300 mm Guidance for specification option: SS. Fixing plate. 400 mm Guidance for specification option: SP. PVC sheet. Fixing plate: 230 mm. 500 mm Guidance for specification option: SBS. Bitumen sheet. Fixing plate: 230 mm. |
Height | 300 mm 400 mm 600 mm Bespoke Manufacturer guidanceUpstand height. |
Warranty description | Ten year Guidance for specification option: See warranty statement for details. |
Uniclass | |
CAWS | J41/14 Reinforced bitumen membrane inverted roof covering J31/130 Inverted roof coating J41/125 Single-layer reinforced bitumen membrane inverted roof covering J41/120 Built-up reinforced bitumen membrane inverted roof covering J31/12 Inverted roof coating J31/5 Cold deck roof coating J31/120 Warm deck roof coating J41/110 Built-up reinforced bitumen membrane warm deck roof covering Q37/130 Extensive green roof Q37/120 Simple intensive green roof Q37/110 Intensive green roof J41/115 Single-layer reinforced bitumen membrane warm deck roof covering J41/130 Built-up reinforced bitumen membrane cold deck roof covering J41/12 Reinforced bitumen membrane cold deck roof covering J41/10 Reinforced bitumen membrane warm deck roof covering J41/135 Single-layer reinforced bitumen membrane cold deck roof covering J31/110 Cold deck roof coating J31/10 Warm deck roof coating |
Material | Stainless steel.Guidance for specification option:
|
Factory finish | |
Coating | Stainless steel components: Manufacturer's standard. |
Colour | Stainless steel components: Manufacturer's standard. |
Configuration | Base plate, upstand, hood, gasket and bitumen-coated stainless steel flange.Guidance for specification option: Refer to drawings where appropriate. |
Dimensions | |
Services requirements | 48 mm. |
Integral kerb | 300 mm.400 mm.600 mm.Manufacturer guidanceUpstand heights. |
Accessories | Manufacturer guidanceConsult manufacturer and insert requirements. |
Finish | Bitumen-coated. Manufacturer guidanceFlange finish. |
Contains Red List materials | No |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Material | Stainless steel Aluminium EPDM Bitumen Guidance for specification option: SBS-modified bitumen. Styrene butadiene |
Recyclability | Yes |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 60 % |
Expected Life | 30 year |