Verified by manufacturer 7 months ago
Cabin width >1500 mm
The SHERPA® is a space-saving goods-only lift. It is a machine-room-less chain lift for low and medium height buildings with integrated shaft for the transportation of goods without attendant.
The SHERPA® goods lifts are a cost-effective, efficient solution and can be used for a variety of applications. The quick and easy installation does not require any construction modifications and enables uninterrupted day-to-day operations even during assembly.
The SHERPA® goods lifts are ideally suited for use in distribution and logistics companies and can easily be integrated into existing shelving systems and mezzanine levels.
In production facilities, goods can be transported between different levels more quickly and efficiently, thus greatly simplifying and improving process flows.
Whether exhibits, archive files or supplies – with our goods lifts, a quick and safe transport is ensured without affecting visitor traffic in public buildings.
In hospitals and medical facilities, medical supplies, clean laundry and groceries are delivered daily. A centrally located passenger or bed elevator is often not sufficient. Our goods lifts are a sustainable solution for optimising logistics.
In office buildings, the use of goods lifts can significantly relieve and safeguard the existing passenger lifts while increasing the attractiveness of rental space by making the transport of furniture and equipment easy.
Thanks to the fast and safe transportation of everyday necessities, waste and laundry away from the guests in hotels, our goods lifts can make a fundamental contribution to a positive visitor experience.
The installation of our SHERPA® goods lifts permanently enables the fast and safe transport of consumer goods and food between delivery and sales areas in event venues and shopping centres.
Space saving goods-only lift.
Features and benefits:
Technical data Sherpa:
Goods with attendant lift also available, specified separately (ESCORTA®).
Color | Beige Black Blue Bronze Brown Manufacturer guidanceContact manufacturer for any colour. |
Finish | Galvanized |
Material | Steel Guidance for specification option: Galvanized. |
Shape | Rectangle |
Length | Bespoke Manufacturer guidance1200–4500 mm. |
Width | Bespoke Manufacturer guidance900mm to 2,800mm |
Height | Bespoke Manufacturer guidanceCabin height 1,800mm to 2,800mm |
Warranty description | One year |
Uniclass | |
CAWS | X12/110 Vertical lifting platform systems X12/110 Vertical lifting platform systems |
Lift type | Accessible goods-only lift. |
Lift components | Free-standing self-supporting lift shaft; cabin; integrated drive.Guidance for specification option:
|
Door configuration | Single entrance (front only), two floors.Guidance for specification option: Number of entrances/ doors to match number of stops specified (See Lift height below). Single entrance (front only), three floors.Guidance for specification option: Number of entrances/ doors to match number of stops specified (See Lift height below). Single entrance (front only), four floors.Guidance for specification option: Number of entrances/ doors to match number of stops specified (See Lift height below). Single entrance (front only), five floors.Guidance for specification option: Number of entrances/ doors to match number of stops specified (See Lift height below). Single entrance (front only), six floors.Guidance for specification option: Number of entrances/ doors to match number of stops specified (See Lift height below). Doors opposite/ through car, two floors.Guidance for specification option: Insert requirements for number of entrances/ doors (Two, three or four). For each floor, define for each opening whether a double swing door or no door is required. Doors opposite/ through car, three floors.Guidance for specification option: Insert requirements for number of entrances/ doors (Three, four, five or six). For each floor, define for each opening whether a double swing door or no door is required. Doors opposite/ through car, four floors.Guidance for specification option: Insert requirements for number of entrances/ doors (Four, five, six, seven or eight). For each floor, define for each opening whether a double swing door or no door is required. Doors opposite/ through car, five floors.Guidance for specification option: Insert requirements for number of entrances/ doors (Five, six, seven, eight, nine or ten). For each floor, define for each opening whether a double swing door or no door is required. Doors opposite/ through car, six floors.Guidance for specification option: Insert requirements for number of entrances/ doors (6, 7, 8, 9, 10, 11 or 12). For each floor, define for each opening whether a double swing door or no door is required. |
Drive type | Machine room-less. |
Drive position | Integrated in shaft head. |
Speed control | Manufacturer's standard. |
Rated load | Manufacturer guidanceInsert requirements; 500–4500* kg. Individually configured lifts have a load range of 500–3000* kg. Maximum load is also dependent on cabin size specified; consult manufacturer for full details. |
Pit opening | Required. Guidance for specification option: Pit depth required is between 70 and 150 mm, dependent on load capacity. Consult manufacturer for details. Not required (ramp). Guidance for specification option: Chequered plate metal, primed in RAL 9016 Pebble grey as standard. Other colours and/ or a side bevel available on request. |
Cabin | 2000 x 2500 x 2000 mm. Guidance for specification option: Width x depth x height. Bespoke. Guidance for specification option: Insert requirements:
|
System accessories | None. Frequency converter. Fire-rated doors, E120/ EI05/ EW30. Fire-rated doors, E120/ EI15/ EW60. Door dampers. Guidance for specification option: Prevents the door slamming shut with subsequent noise generated. Also protects the door and the door hinges. Note: Not classified as fire-resistant under EN 81-58. |
Lift height | Manufacturer guidanceInsert requirements for:
|
Shaft | Manufacturer guidanceInsert requirements:
|
Colour | Galvanized. Powder-coated. Guidance for specification option: Consult manufacturer for colour options and insert requirements. All common Classic RAL colours are available (metallic and neon colours are not possible). Manufacturer guidanceShaft colour/ finish. |
Control cabinet | Manufacturer guidanceInsert placement requirements:
Painted in RAL 7035 as standard. Ingress protection: IP54 without a frequency converter; IP44 with a a frequency converter. The size of the control cabinet will vary depending on the lift configuration; consult manufacturer for details. |
Speed | 0.2 m/s. |
Door configuration | Double swing doors only. Guidance for specification option: Cabin width >1500 mm only. Double swing/ no door combinations. Guidance for specification option: Cabin width >1500 mm only. Specify front and back combinations of door/ no door requirements per floor. Minimum of one door required per floor (adjust distance between floors if one level of the building is to be bypassed). Manufacturer guidanceDoor size determined by cabin size. No door handle shells on the inside of the doors as standard. |
Door colour | Traffic red. Sky blue. Dusty grey. Primed (RAL 9016 Pebble grey). Other, Classic RAL. Guidance for specification option: Consult manufacturer for options and insert requirements. All common Classic RAL colours are available (metallic and neon colours are not possible) |
Landing operating panels | Manufacturer's standard, to left-hand side of door. Manufacturer's standard, to right-hand side of door. |
Flooring | Manufacturer's standard. Guidance for specification option: Smooth sheet metal with a two-component anti-slip coating (epoxy resin-based, solvent-free and non-slip coating in RAL 7040). Steel tear plate. Guidance for specification option: Painted to match door colour. Aluminium tear plate. Manufacturer guidanceFor lifts up to maximum 1000 kg nominal load and maximum 1400 mm cabin width, galvanized platforms are standard. |
Length | 1200–4500 mm. |
Contains Red List materials | No |
Country of product manufacture | Germany |