Verified by manufacturer 4 months ago
Skyline Self-Supporting Skylight - Gable Ended
CHAS
Certificate type
Constructionline
Certificate type
ISO 45001 Health and Safety Management
Certificate type
ISO 9001 Quality Management
Certificate type
Achilles Information Limited - Procurement Management
Certificate type
Self-supporting skylight with slim, external extruded aluminium capping.
Roof glazing applications, to be used in conjunction with Skyline patent glazing.
Self-supporting skylight with slim, external extruded aluminium capping.
Features and benefits:
Color | Other Guidance for specification option: Available in non-metallic RAL colour requirement from the standard range. |
Finish | Powder-coated Guidance for specification option: To BS 6496. |
Material | Glass Aluminium Guidance for specification option: Grade 6063 temper T6 aluminium alloy, conforming to BS EN 755-2. |
Shape | Pentagon Hexagon Octagon Other Guidance for specification option: Other polygonal shapes:
Rectangle |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | Five year |
Uniclass | |
CAWS | H10/10 Patent glazing H10/115 Patent glazing L10/45 Rooflights L10/460 Rooflights |
Product range |
Form | Gable ended.Guidance for specification option: Without vertical glazed upstand. |
Size | Guidance for specification option: Consult manufacturer and insert requirements. |
Frame | |
Material | Aluminium. |
Finish | |
Coating | Powder coating to BS EN 13438. |
Colour | Guidance for specification option: Consult manufacturer and insert requirements.
|
Film thickness (minimum) | 40 µm. |
Glazing or infill | |
Type | Guidance for specification option: A variety of glazing infill is available, e.g. clear laminated, heat soaked toughened, etc. Consult manufacturer's literature for information. |
Construction | Guidance for specification option: Consult manufacturer and insert requirements. |
Integral kerb | Aluminium.Guidance for specification option: The raised upstand kerb should be 100 mm wide (minimum). |
Operation | |
Type | Manual.Powered, electric.Pneumatic. |
Control | Not applicable.Electric control - chain actuator, 24 V.Electric control - chain actuator, 230 V.Electric control - linear actuator, 24 V.Electric control - linear actuator, 230 V.Manual control - screwjack gear.Pneumatic control - gas springs. |
Accessories | Guidance for specification option: Consult manufacturer and insert requirements. |
Supporting structure | Concrete. Steel. Timber. Manufacturer guidanceThe raised upstand kerb should be 100 mm wide (minimum). |
Slope | 15°. 20°. 25°. 30°. 35°. |
Vertical glazed upstand height | Not required. Guidance for specification option: If specifying Gable Ended, Hipped or Polygonal. 500 mm. 600 mm. 700 mm. 800 mm. |
Trim | Aluminium cap. |
Hardware | Manufacturer's standard. |
Type | SPG2. Guidance for specification option: Depth: 55 mm. SPG3. Guidance for specification option: Depth: 75 mm. SPG4. Guidance for specification option: Depth: 100 mm. Manufacturer guidanceGlazing bar. Consult manufacturer before specifying a particular glazing bar. |
Capping | PC1, extruded aluminium cap. Manufacturer guidanceGlazing bar. |
Outer pane | Guidance for specification option: Insert requirements e.g. clear laminated, heat soaked toughened, etc. Consult manufacturer's literature for information. When 28 mm thick double glazed units are used, a centre pane thermal transmittance (U-Value) of at least 1.15 W/m²K can be achieved. Manufacturer guidanceGlazing infill. |
Cavity | 16 mm Argon gas filled cavity with warm edge spacer bars. Manufacturer guidanceGlazing infill. |
Inner pane | Guidance for specification option: Insert requirements e.g. clear laminated, heat soaked toughened, etc. Consult manufacturer's literature for information. When 28 mm thick double glazed units are used, a centre pane thermal transmittance (U-Value) of at least 1.15 W/m²K can be achieved. Manufacturer guidanceGlazing infill. |
Type | Not required. Bottom hung, thermally broken. Side hung, thermally broken. Top hung, thermally broken. Manufacturer guidanceOpening vents. |
Quantity | Guidance for specification option: 1–20, insert requirements. If opening vents are not required, insert N/A. Manufacturer guidanceOpening vents. |
Controls | Not applicable. Crank handle. Guidance for specification option: For use with screwjack gear. Standard open/ close wall mounted switch. Guidance for specification option: For electric actuators. Wall mounted thermostatic control panel with rain sensor. Guidance for specification option: For electric actuators. Manufacturer guidanceOpening vents. |
Contains Red List materials | No |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Material | Glass Aluminium Guidance for specification option: Grade 6063 temper T6 aluminium alloy, conforming to BS EN 755-2. |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | 100 kg CO₂ eq/unit Self declared |
Recyclability | Recyclable |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 100 % |
Expected Life | Lifetime |