Verified by manufacturer 4 days ago
Tental 60 MT Feature cap
EPD
Certificate type
CWCT Certificate
Certificate type
Passive House Institute - Certificate
Certificate type
Cradle to Cradle Certified
Certificate type
60 mm wide aluminium profile curtain walling.
Suitable for optimising grids of residential and commercial buildings, new builds or renovations. Particularly suitable for:
The TENTAL curtain wall offers an extensive range of solutions and creative freedom when designing a facade. It allows modular curtain wall designs with large glazing units to enable maximum transparency with a minimal sightline.
It uses Hydro CIRCAL®, an alloy made with a minimum of 75% recycled end-of-life aluminium, allowing tons of scrap that would otherwise become waste be reintroduced into the system. The thermal break elements are made from recycled xPET, a material that gives a second life to used plastic drinks bottles. Therefore, the TENTAL curtain wall is a suitable solution for current needs in terms of design and sustainability in the building industry.
Features and benefits:
Color | Other Guidance for specification option: A full pallet of exclusive colours. Consult manufacturer. |
Finish | Powder-coated Anodized |
Material | Aluminium Acrylonitrile butadiene styrene (ABS) Foam |
Length | 50 mm 250 mm Manufacturer guidanceDepth. |
Width | 60 mm |
Height | Bespoke |
Uniclass | |
CAWS | H11/110 Curtain walling |
Product range |
Classification data | |
System performance | Tested in accordance with the requirements of EN 13830. |
Framing | |
Frame members | Hydro CIRCAL® aluminium alloy 6060 T66 sections, extruded to EN 12020, EN 573-3, EN 515 and EN 775-1 to 9. Guidance for specification option:
|
Frame accessories | Horrizontal and vertical caps. Horrizontal caps. Vertical caps. Flush caps. Bespoke caps. |
Cladding units | |
Glass units | Insulated glass units (IGUs). Guidance for specification option:
|
Panels and facings | |
Material | Opaque infill, spandrel panels and louvres to be tested and classified to Class A2-s1, d0 or A1 according to BS EN 13501-1:2007+A1:2009 for reaction to fire. Guidance for specification option: Consult manufacturer and insert material requirements. |
Thermal insulation | Standard Hi Insulation. Manufacturer guidanceConsult manufacturer and insert requirements. |
Perimeter seals | EPDM membranes, ≤ 250 mm width. Guidance for specification option: In accordance with CWCT/ SFE 'Technical Guidance for interpretation in relation to external walls and specified attachments of Relevant Buildings in England issue 2, July 2023'. |
System completion | Submit EcoPlatform third party published EPD conforming to ISO 14025 and EN 15804+A2. |
Coating | Polyester powder-coated in accordance with BS EN 12206-1: 2021. Minimum thickness: 60 microns. Guidance for specification option: Any special warranties or guarantees (such as marine or industrial/ chlorine) to be issued directly by the powder supplier and agreed prior to material order. Anodized to BS 3987:1991. Minimum thickness: 25 microns. Manufacturer guidanceAll finishing to be undertaken by Hydro Building Systems prior to delivery to the manufacturer. |
Colour | Standard Technal finish from standard Technal range. Guidance for specification option: Differing finishes internally and externally possible. Consult manufacturer and insert requirements. |
Texture | Gloss. Matt. Satin. |
Watertightness | RE900 (900 Pa). |
Air permeability | AE750 (750 Pa). |
Resistance to wind load | 2400 Pa (3600 Pa safety). |
Impact resistance | E5/I5. |
Load | 850 kg. |
Burglar resistance | To EN 1627 RC2, RC3 and PAS 24. |
Aluminium curtain wall frame sections | Recycled content: Minimum of 75% recycled end-of-life aluminium (post-consumer scrap). Embodied carbon: GWP (A1-A3) of no greater than 1.9 kg of CO2e/kg of aluminium. |
Contains Red List materials | No |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Material | Aluminium Acrylonitrile butadiene styrene (ABS) Foam |
| Carbon dioxide equivalent | |
Carbon dioxide equivalent, as defined in BS EN 15804 Certified | |
Stage Normalised unit (kg CO₂ eq/kg) Declared unit (kg CO₂ eq/kg) Stage:A1–A3 ('Production stage') Normalised unit : 1.9 (kg CO₂ eq/kg) Declared unit : 1.9 | |
Recyclability | 95% |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 75 % |
Expected Life | 50 year |