Verified by manufacturer 1 day ago
GEV-EMICODE® EC1 PLUS
Certificate type
Non-combustible and solvent-free anti-drumming compound. Noise and vibration control to aluminum coping & rainscreen panels.
Suitable for a variety of corrosion-protected metals. Designed for deadening and absorption of structure-borne sounds caused by thin-walled sheet metal structures. Can also be used as an anti-condensation coating.
Typically used for:
Non-combustible and solvent-free anti-drumming compound for eliminating vibrations and drumming of sheet metal and metal parts.
Features and benefits:
Consult manufacturer for surface preparation and application details.
Color | Beige |
Finish | Other |
Material | Resin Guidance for specification option: Aqueous synthetic resin dispersion. |
Shape | Formless |
Uniclass | |
CAWS | F30/171 Ventilation ducts in external walling F30/17 Ventilation ducts in external walling K40/10 Unit/ modular suspended ceilings H31/10 Metal K40/115 Unit/ modular suspended ceiling system H31/120 Metal |
Certification | EMICODE EC 1 PLUS. |
Fire performance | To DIN EN 13501, A2-s1,d0. |
Density | Wet: ~1.4 g/cm³. Dry: ~1.2 g/cm³. |
Temperature resistance | -50°C to +120°C. |
Application temperature | 10–40°C. |
pH value | ~9. |
Solids content | ~66.5%. |
Drying time | ~24 hours. Guidance for specification option: At standard climate, DIN 50014. At 40°C: 8 hours. At 80°C: 3 hours. Manufacturer guidanceBased on 4 mm wet film. |
Consumption (per layer applied) | ~1.4 kg/m². Manufacturer guidancePer 1 mm dry film. |
Thermal transmittance (U-Value) | To DIN 52612, 0.21 W/mK. |
Adhesion strength | To ASTM D 3359, 5A. |
Acoustic performance | Loss factor to DIN EN ISO 6721-3, ≥0.22 Guidance for specification option: Consult manufacturer's datasheet for in depth loss factor information. |
Material | Resin Guidance for specification option: Aqueous synthetic resin dispersion. |