Verified by manufacturer 10 months ago
Terrazza Originale
Glass patio roofs with multiple design features.
Patio roof with multiple protection options.
Glass patio roofs with multiple design features.
Features and benefits:
Color | Clear Silver Black Blue Bronze |
Finish | Powder-coated |
Material | Aluminium Glass Plastic |
Shape | Rectangle Square |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | Other Guidance for specification option: Warranty offered by the approved specialist partner. Please consult manufacturer as various warranties are available. |
Uniclass | |
CAWS | B91/385 Shelter B91/330 Canopy |
Classification data | |
Shelter description | Patio roof without overhang, with integrated guttering. |
Dimensions | |
Plan size | Guidance for specification option: Insert requirements.
|
Height | Guidance for specification option: Consult manufacturer for options and insert requirements. |
Fire performance | |
Fire resistance | Manufacturer's standard. Guidance for specification option: Consult manufacturer for details. |
Reaction to fire | Manufacturer's standard. Guidance for specification option: Consult manufacturer for details. |
Frame | |
Material | Aluminium, roof support profile type S. Guidance for specification option: Maximum roof depth: 3 m. Aluminium, roof support profile type L. Guidance for specification option: Maximum roof depth: 6 m. |
Finish | Powder-coated. Manufacturer guidanceProfiles are cut prior to powder-coating for optimum corrosion resistance. |
Colour | Guidance for specification option: More than 200 frame colours available. Consult manufacturer for details and insert requirements. |
Roof covering | Aluminium profiles with 10 mm laminated safety glass (LSG). Aluminium profiles with 12 mm laminated safety glass (LSG). |
Openings | |
Doors | None. Folding and sliding wall - Side element LITE. Guidance for specification option: Lightweight fixed glazing at the top of the trapezium, with a Weinor easy-glide sliding wall underneath, or a multi-function folding partition. Side element CLASSIC. Guidance for specification option: Sturdy fixed glazing at the top of the trapezium, with a multi-function sliding wall below. weinor Glasoase®. Guidance for specification option: Glass sliding doors; consult manufacturer for details. Manufacturer guidanceSee Windows for fixed side glazing options. |
Windows | Not required. Vertical glass elements. Guidance for specification option: Range of options, including fixed glazing below the side roof support or a separate section at the top of the trapezium. |
Roof vents | Required. Not required. |
Integral services | Cabling for power and lighting. |
Rainwater drainage | 160 guttering, drainage covered. Guidance for specification option: Standard guttering size. 160 guttering, drainage outside. Guidance for specification option: Standard guttering size. 220 guttering, drainage covered. Guidance for specification option: Only available with 115 square posts, and selected roof types - see Roof type for details. 220 guttering, drainage outside. Guidance for specification option: Only available with 115 square posts, and selected roof types - see Roof type for details. |
Accessories | None. Underlay sun protection. Overlay sun protection. Vertical sun protection. Tempura/ Tempura Quadra heating system. LED light bar. Manufacturer guidanceConsult manufacturer's literature for options and detail, and insert requirements where applicable. |
Roof pitch | Guidance for specification option: Insert requirements. 3–15° available as standard; for pitches over 15° (up to and including 45°) consult manufacturer. Note that with pitches <5° there are a number of restrictions and points of caution. Consult manufacturer for details. |
Snow load | 750 N/m². Guidance for specification option: Standard. Up to 5500 N/mm². Guidance for specification option: Consult manufacturer for details and insert requirements. |
Posts | 115 post (square). Guidance for specification option: Not available with all roof types; see Roof type for details. 90 post (round). Guidance for specification option: Cannot be specified with 220 guttering. |
Roof type | Pent roof - Type A. Guidance for specification option: Standard rectangular roof. Depending on the design, differing distances between centre lines and the resultant additional roof panels can occur. Pent roof type A with wall offset. Guidance for specification option: Depending on the design, differing distances between centre lines and the resultant additional roof panels can occur. Pent roof type A with balcony recess. Guidance for specification option: Depending on the design, differing distances between centre lines and the resultant additional roof panels can occur. Pent roof type A with guttering offset. Guidance for specification option: Depending on the design, differing distances between centre lines and the resultant additional roof panels can occur. Available with 160 guttering only. Pent roof type A tapered wall bracket left/right. Guidance for specification option: Pent roof with tapered wall bracket or partially tapered wall bracket. Available with 160 guttering only. Pent roof type A tapered guttering left/right. Guidance for specification option: Pent roof with tapered guttering or partially tapered guttering. Available with 160 guttering and 90 post only. Pent roof type B, with bent side roof supports. Guidance for specification option: Maximum width of outer roof panel 1 m; maximum roof depth 4.5 m. Available with 160 guttering only. Pent roof type C, trapezium-shaped sloping to eaves. Guidance for specification option: Maximum width of outer roof panel 1 m; maximum roof depth 4.5 m. Available with 160 guttering only. Pent roof type C, trapezium-shaped sloping to ridge. Guidance for specification option: With continuous guttering. Available with 160 guttering only. Maximum width of outer roof panel 1 m; maximum roof depth 4.5 m. Pent roof type G, with hipped and bevelled sides. Guidance for specification option: With continuous guttering. Available with 160 guttering and 90 post only. Maximum width of outer roof panel 1 m; maximum roof depth 4.5 m. Pent roof type I, with hipped sides. Guidance for specification option: With continuous guttering. Available with 160 guttering and 90 post only. Maximum width of outer roof panel 1 m; maximum roof depth 4.5 m. Pitched roof type L. Guidance for specification option: Maximum width: 6.5 m; maximum roof depth: 6.5 m. Available with 160 guttering only. Observe minimum roof pitch of 5–30°. Pent roof type N, roof plane angled, outer corner always 90°. Guidance for specification option: Hip rafters from two individual roof supports with cover plates. Available with 160 guttering only. Pent roof type R, roof plane angled, inner flute always 90°. Guidance for specification option: Available with 160 guttering and 90 post only. |
Country of product manufacture | Germany |
Material | Aluminium Glass Plastic |