Trimoterm FTV Panel - POWER S - Internal (Firewall)

Verified by manufacturer 2 days ago

60 mm thick

Trimo UK Ltd Variant:

Steel insulated fireproof panels.

Jump to:
+44 (0)1270 665303 Website

Application

The range of applications for the façade system is extremely wide. They are suitable for business, commercial, leisure, trade and industrial buildings.

Description

The façade system consists of Trimoterm FTV panels of standard modular widths 1000 and 1200 mm.

The façade system has excellent technical properties, a long life span and allows creative freedom in building envelope design. The system of Trimoterm fireproof panels ensures high fire resistance, excellent thermal and sound insulation. The panels are used primarily as a façade, partition walls, fire walls and ceilings, or even as a backing panels for variety of rainscreen façade systems. CE marked, LPCB, FM certified.

Panels Composition

Trimoterm FTV fireproof panels consist of two shallow profiled or flat, coated sheet faces in thicknesses of 0.4 to 0.8 mm. The steel sheet is bonded to the panel core made of non-combustible mineral wool lamellas of class A1 (EN 13501-1). All three layers make a solid panel in a thickness of 50–250 mm. Standard width of the panels are 1000 and 1200 mm. Non standard panel width of 600–1200 mm can be made by a special request. A protective PVC film is applied to the panel surface to protect it during production handling and transport. Panels can be manufactured up to 14 m long.

General information

Finish

Galvanized

Guidance for specification option:

Hot galvanized (net 275 g/m² ) in compliance with EN 10346, and additionally protected by organic coating in accordance with the coil-coating process (DIN EN 10169/1).

Painted

Material

Steel

Mineral fibre

Mineral wool

Shape

Rectangle

Square

Length

Bespoke

Width

Bespoke

Height

Bespoke

Warranty description

25 year

Manufacturer guidance

Can be up to 25years must be stated when ordered

Uniclass

Ss_25_12_65_65 Panel partition systemsPrimary

CAWS

H43/120 Metal insulating sandwich panel

H43/10 Metal insulating sandwich panel

Specification data - Panel partition systems

Classification data

Panel partitioning

Factory-assembled insulating sandwich panels.

System accessories

Not required.
L-corner, horizontal.
U-corner horizontal.
L-corner, vertical.
Rounded L-corner, vertical.
Rounded U-corner, vertical.

Standard

To EN 14509.

Material

S320GD steel.

Profile

Micro-lined profile (M).
Micro-lined profile (M3).
S - profile (standard profile).
Smooth profile (G).
V - profile (V).
V - profile (V2).
V - profile (V6).

Guidance for specification option:

1200 mm width.

Manufacturer guidance

External face profile.

Thickness

0.5–0.8 mm.

Manufacturer guidance

External face thickness.

Profile

Micro-lined profile (M2).
S - profile (standard profile).
Smooth profile (G).
V - profile (V).
V - profile (V2).
V - profile (V6).

Guidance for specification option:

1200 mm width.

Manufacturer guidance

Internal face profile.

Thickness

0.4–0.8 mm.

Manufacturer guidance

Internal face thickness.

Core insulation

Stone wool, 120 kg/m³.

Length

Guidance for specification option:

14 m (maximum). Insert requirements.

Cover width

1000 mm.
1200 mm.

Thickness

60 mm.

Material

SP.
HDP.
PUR.
PUR-PA.
PVDF.
PVC(P).
PVC(F).
PET(F).

Manufacturer guidance

Outer skin finish. For corrosion protection details consult technical literature.

Material

SP.
HDP.
PUR.
PUR-PA.
PVDF.
PVC(P).
PVC(F).
PET(F).

Manufacturer guidance

Inner skin finish.

Colour

White RAL 9010.
Grey White RAL 9002.
Cream RAL 1015.
Light Grey RAL 7035.
Agate Grey RAL 7038.
Tele Grey 2 RAL 7046.
Silver RAL 9006.
Dark Silver RAL 9007.
Traffic Red RAL 3020.
Moss Green RAL 6005.
Gentian Blue RAL 5010.
Anthracite RAL 7016.
Other.

Guidance for specification option:

Consult manufacturer for full range of colours and insert requirements.

Fire resistance

Up to EI 30 (horizontal and vertical).

Reaction to fire

External: To EN 13501-1, Class A1 and EN 13501-5, BROOF (t1,t2,t3).
Core: To EN 13501-1, Class A1.
Internal: To EN 13501-1, Class A1.
Overall system: To EN 13501-1, Class A2.

Thermal transmittance (U-Value)

0.65 W/m²K.

Sound insulation

30 (-2;-3) dB.

Water permeability

Class A (1200 Pa).

Air permeability

n = 1.5: C = 0.00005.

Burglary resistance (to BS EN 1627)

RC3.

Sustainability data

Country of material origin

Slovenia

Country of product manufacture

Slovenia

Material

Steel
Mineral fibre
Mineral wool
Carbon dioxide equivalent

Carbon dioxide equivalent, as defined in BS EN 15804

Self-declared

Stage
Normalised unit (kg CO₂ eq/kg)
Declared unit (kg CO₂ eq/m²)
Stage:A1–A3 ('Production stage')
Normalised unit :
Declared unit : 60

Recyclability

99%

Guidance for specification option:

Up to 99%.

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

40 %

Guidance for specification option:

Up to.

Literature

Trimoterm Fire Application

Trimoterm Fire Application

Architectural Details - Fire-resistant Internal Wall System

Architectural Details - Fire-resistant Internal Wall System

Trimoterm Technical Specification -

Trimoterm Technical Specification -

Similar products from Trimo UK Ltd

Trimoterm FTV Panel - POWER T - Internal (Firewall)

Trimoterm FTV Panel - POWER T - Internal (Firewall)