NBS Source
I'm a manufacturer
Compare variants

Trisobuild® VW/ FWV - Self-Supporting Cladding System.

Verified by manufacturer 6 days ago

Trisobuild® FW30V

Tata Steel Variant:
Third party certifications:
  • BRE Certificate

    BRE Certificate

    Certificate type

  • BES 6001

    BES 6001

    Certificate type

  • ISO 14001 Environmental Management Systems

    Certificate type

  • ISO 9001 Quality Management

    Certificate type

  • EPD

    EPD

    Certificate type

Site-assembled non-combustible wall cladding system (vertical orientation).

Jump to:
+44 (0) 1244 892199 Website

Application

Suitable for vertical design wall cladding applications.

Description

Site assembled walling system with internal and external profiles.

The Trisobuild® systems can be tailored to meet project requirements including fire resistance and acoustic performance. The system comprises of a Colorcoat® pre-finished steel trapezoidal liner profile, an Instaloc® Plus spacer system, an insulation layer and a Colorcoat® pre-finished steel external weathering profile.

The Trisobuild® VW System is a vertically run wall system which can provide an efficient external cladding system. The system provides the designer with an infinite number of combinations to create a unique aesthetic.

The capability of the systems can also allow the designer to specify the correct performance for the building and elevation. With tested components, the system provides a range of thermal, acoustic and fire resistance performance levels. The wall system can achieve up to four hours fire integrity and one hour fire insulation.


Features and benefits:

  • Certified 'very good' to Building Research Establishment (BRE)'s responsible sourcing standard BES 6001.
  • Available with Platinum® Plus - a system guarantee for up to 25-years, that covers the durability, structural and thermal performance of all system components. The guarantee is derived from a tailored specification to suit your building function and is fully transferable on change of ownership of the building.
  • Loss Prevention Certification Board (LPCB) LPS 1181-1 approved 460a 14, 15, 19, 23 and 31.
  • The insulation within the system has both zero ozone depletion potential (ODP) and low global warming potential (GWP). Both these factors support the achievement of a high Building Research Establishment Environmental Assessment Method (BREEAM) rating.
  • Trisobuild® wall systems have been third party assessed using BS 476–22 ‘Fire resistance of non-load bearing elements’.
  • All steel elements are recyclable, without any loss of quality. The insulation can be separated easily and if kept ‘clean’ can be recycled. A product specific environmental product declaration (EPD) is available for all Trisobuild® systems.


Trisobuild® FW (fire wall) range system build-up:

  • The resistance to fire insulation and integrity in minutes are: FW30V: 30/240, FW60V: 60/240.
  • For the FW30V system, a minimum 160 mm Knauf FactoryClad insulation quilt should be used. For the FW60V system, a minimum of 200 mm Rockwool quilt of nominal density 24 kg/m³ should be used.
  • External profile, side lap stitching is optional but recommended at a maximum 500 mm centres for aesthetic reasons only.
  • Minimum 140 mm high Instaloc® Plus spacer system for the FW30H system should be used and 180 mm for FW60H.
  • Internal liner profile.


Supporting structures:

  • When sheeting rails heat up during a fire they cease to function as structural members. Therefore, to prevent the wall from moving downwards under its own self-weight either a support at the head or base of the wall is required.
  • All Tata Steel firewalls can be designed to be supported from eaves, beams/ stanchions or rafters and posts if situated on a gable end. However, these elements must be protected using conventional fire protection materials to give the same period of fire resistance as the firewall.


Reaction and resistance to fire:

  • All Trisobuild® VW systems have an internal reaction to fire classification of A1 and an external reaction to fire of A1 when using Colorcoat Prisma®, and when using Colorcoat HPS200 Ultra® is deemed to satisfy B-s3-d2 in accordance with ADB2.
  • All fire wall system performances have a maximum span limit between supports of 1.525 m.


Thermal performance:

All quoted system U-values and construction ‘psi’ and f values have been computer modelled in accordance with EN ISO 10211 as stated in the Metal Cladding and Roofing Manufacturers Association (MCRMA) Technical Note 14 by trained and experienced technical engineers.

U-Values are based on secondary steelwork support at 1.8 m centres, 1.2 m bracket spacing and insulation with a 0.040 W/mK thermal conductivity.


U-values:

U-Values are based on an LP1000 liner, secondary steelwork support and brackets at 1.5 m centres, 1.5 m vertical bar spacing and insulation with a 0.040 W/mK thermal conductivity.

General information

Color

Other

Manufacturer guidance

Wide range available.

Finish

Coated

Material

Steel

Length

Bespoke

Width

Bespoke

Height

Bespoke

Warranty description

25 year

Uniclass

Ss_25_20_68_50 Metal profiled sheet self-supporting cladding systemsPrimary

CAWS

H31/10 Metal

H31/120 Metal

Product range

Trisobuild

Specification data - Metal profiled sheet self-supporting cladding systems

Thermal insulation

A minimum 160 mm Knauf FactoryClad insulation quilt.

External sheets

-

Material

Carbon steel insulating sandwich panels

Material

Colorcoat HPS200 Ultra® pre-finished steel.

Colorcoat Prisma® pre-finished steel.

Grade

S220 Steel.

Profile

Various.

Guidance for specification option:

Insert requirements.

Thickness

0.5 mm.

0.7 mm.

Material

Colorcoat® High Reflect steel.

Colorcoat® PE 15 steel.

Grade

S220 Steel.

Profile

LP1000.

Thickness

0.4 mm.

Length

-

Manufacturer guidance

Maximum span limit between supports of 1.525 m.

Thickness

-

Manufacturer guidance

Consult manufacturer and insert requirements.

Material

Pre-coated steel.

Colour

-

Manufacturer guidance

Insert requirements.

Material

Pre-coated steel.

Colour

-

Manufacturer guidance

Insert requirements.

Span

As drawing.

Guidance for specification option:

Insert details.

Height

140 mm.

Guidance for specification option:

Insulation depth: 140 mm. U-value: 0.30 W/m²K.

160 mm.

Guidance for specification option:

Insulation depth: 160 mm. U-value: 0.26 W/m²K.

180 mm.

Guidance for specification option:

Insulation depth: 180 mm. U-value: 0.23 W/m²K.

200 mm.

Guidance for specification option:

Insulation depth: 200 mm. U-value: 0.21 W/m²K.

220 mm.

Guidance for specification option:

Insulation depth: 220 mm. U-value: 0.19 W/m²K.

Show more

Reaction to fire

A1.

Guidance for specification option:

Panel external face.

Panel internal face

Integrity: 240 minutes. Insulation: 30 minutes.

Sustainability data

Country of product manufacture

United Kingdom

Material

Steel

Manufacturing plant location

Recyclability

100%

Manufacturer guidance

All steel elements are recyclable, insulation is recyclable if kept clean.

Third party certifications

Third party certifications

BRE Certificate

BRE Certificate

Loss Prevention Certification Board - Certificate 460a

BES 6001

BES 6001

BES 6001

ISO 14001 Environmental Management Systems

ISO 14001 Environmental Management Systems

ISO 14001 / 45001

ISO 9001 Quality Management

ISO 9001 Quality Management

ISO 9001

EPD

EPD

EPD Trisobuild site-assembled Roofing & Wall Cladding - 0.26 u-value

EPD

EPD

EPD Trisobuild site-assembled Roofing & Wall Cladding - 0.24 u-value

EPD

EPD

EPD Trisobuild site-assembled Roofing & Wall Cladding - 0.18 u-value

Literature

Colorcoat® LG colour card

Colorcoat® LG colour card

Trisobuild® specification and installation guide

Trisobuild® specification and installation guide

TATA Building Systems UK - All products brochure

TATA Building Systems UK - All products brochure

LPCB Certificate

LPCB Certificate

Optemis Carbon Lite

Optemis Carbon Lite

Platinum® Plus Approved Suppliers

Platinum® Plus Approved Suppliers

Platinum® Plus system guarantee

Platinum® Plus system guarantee

Case studies

Port of Leith Distillery - A distillery like no other in Scotland

Port of Leith Distillery - A distillery like no other in Scotland

Circularity - Repurposing the Industrial Landscape

Circularity - Repurposing the Industrial Landscape

Kohler Mira, state-of-the-art national distribution centre

Kohler Mira, state-of-the-art national distribution centre

Similar products from Tata Steel

Trisobuild® HW/ FWH - Self-Supporting Cladding System.

Trisobuild® HW/ FWH - Self-Supporting Cladding System.