Verified by manufacturer 2 days ago
The more compact and space-conscious fire shutter solution, fully tested and certified in accordance with the latest fire standards BS EN 1634-1:2014 + A1:2018 and BS EN 16034:2014.
For internal use requiring fire rating, particularly smaller, compact applications.
The more compact and space-conscious fire shutter solution, fully tested and certified in accordance with the latest fire standards BS EN 1634-1:2014 + A1:2018 and BS EN 16034:2014.
Test report: Warrington Fire WF Report No. 410300 dated of 27th June 2019 in accordance with BS EN 1634-1 2014+ A1 2018.
Features and benefits:
Fire operation:
The control panel is designed to accept a 24 V d.c. or volt-free fire signal.
Components:
Color | Silver Other |
Finish | Galvanized Powder-coated |
Material | Steel |
Shape | Rectangle Square |
Width | Bespoke |
Height | Bespoke |
Uniclass | |
CAWS | L20/60 Doors L20/610 Roller shutters/ curtains |
Standard | To BS EN 1634-1:2014 + A1:2018 and BS EN 16034:2014.Manufacturer guidanceTest report: Warrington Fire WF Report No. 410300 dated of 27th June 2019 in accordance with BS EN 1634-1 2014+ A1 2018. |
Opening sizes | Guidance for specification option: Consult manufacturer for options and insert requirements. |
Format | Internal. |
Arrangement | Vertical, face-fitted across opening. |
Performance | |
Fire performance | |
Fire resistance | One hour fire rating.Two hour fire rating.Four hour fire rating. |
Watertightness | Manufacturer's standard.Guidance for specification option: Consult manufacturer for details. |
Resistance to wind load | To BS EN 12424, up to Class 3. |
Acoustic performance | Manufacturer's standard.Guidance for specification option: Consult manufacturer for details. |
Thermal resistance | Manufacturer's standard.Guidance for specification option: Consult manufacturer for details. |
Air permeability | Manufacturer's standard.Guidance for specification option: Consult manufacturer for details. |
Frame and guides | |
Material | Steel.Guidance for specification option: Bottom rail:
Side guides and angles:
Roller barrel:
Endplates:
Coil casings:
|
Finish | Galvanized.Powder-coating.Guidance for specification option: Note that additional cost applies, consult manufacturer for details. |
Colour | Galvanized.Other.Guidance for specification option: Insert colour requirements, RAL or BS. Note that additional cost applies, consult manufacturer for details. |
Film thickness (minimum) | Manufacturer's standard (where applicable). |
Installation fasteners | Guidance for specification option: Insert requirements to suit structure. Can be fitted to masonry or steelwork openings. |
Frame accessories | Guidance for specification option: Consult manufacturer for options and insert requirements, or omit. |
Shutter curtain | |
Lath material | Galvanized steel.Guidance for specification option:
|
Profile | Concave, plain, 76 mm. |
Finish and colour | Galvanized.Powder-coating.Guidance for specification option: Insert colour requirements, RAL or BS. Note that additional cost applies, consult manufacturer for details. |
Weight | 45 kg/m². |
Mode | Automatic, electric 240 V single-phase tube motor; fire operation. Guidance for specification option: Fire operation: The control panel is designed to accept a 24 V d.c. or volt-free fire signal.
Manufacturer guidanceDiscreetly fitted within the door roller-barrel. The system also comprises a control panel combining an un-interruptible power supply and the operation interface for normal and fire operation. |
Control | Key switch. Rocker switch. |
Accessories | None. Audio visual warning panel. Guidance for specification option: Provides a warning that the fire shutter is about to close automatically via the fire alarm system. The panel requires a 240 V supply together with an appropriate signal from the fire alarm system. The panel also includes a battery backup system and an adjustable timer close facility. Sentry control panel. Guidance for specification option: Constantly monitors the strength of the fire alarm signal and warns if the signal is weak. The unit comes complete with a battery backup facility which charges on a trickle feed from the mains supply to ensure sufficient charge for use in the event of power failure. The Sentry control panel also monitors the charge level of the battery and warns if it is low. Should the battery level be critically low then the panel will signal the fire shutter to close. |
Material | Steel |