Top hung movable acoustic wall.
To limit noise transmission between rooms.
Sliding stacking panel partition.
Features and benefits:
Color | Manufacturer guidanceStandard Laminate, factory spray painted, fabric wrapped panels, high pressure laminate, veneer, white board, magnetic white board or to clients requirements |
Finish | Manufacturer guidanceStandard Laminate, factory spray painted, fabric wrapped panels, high pressure laminate, veneer, white board, magnetic white board or to clients requirements |
Material | Aluminium Glass |
Shape | Rectangle |
Length | Bespoke Manufacturer guidance1200mm wide x 20000mm high maximum panel dimension |
Width | Bespoke Manufacturer guidance1200mm wide x 20000mm high maximum panel dimension |
Warranty description | Two year |
Uniclass | |
CAWS | K30/76 Glazing for relocatable partitions K30/480 Glazing for relocatable partitions L20/545 Sliding stacking panel partitions |
Performance | Up to 60 dB to EN ISO 140-3.Guidance for specification option:
|
Operation | E: Fully electric.Guidance for specification option:
M: Manual.Guidance for specification option:
SE: Semi-electric.Guidance for specification option:
|
Dimensions (nominal) | |
Panel (average) | |
Width | Guidance for specification option: Up to 1230 mm (maximum). Wider panels possible to special order; insert requirements. |
Height | Guidance for specification option: Minimum: 1.5 m up to 15 m *maximum); insert requirements. |
Thickness | 19 mm. |
Track system | |
Wall jamb and abutments | Finished to match panels as standard.Manufacturer guidance
|
Panels | |
Construction | Internal bracket frame with double skin cladding of 19 mm thick, three layer, high density chipboard. |
Finish as delivered | Back painted glass.Client supplied fully finished boards.Guidance for specification option: Insert details as required. Factory spray paint to RAL colour.Guidance for specification option: Insert requirement. High pressure laminate.Lacquered steel sheet to RAL colour.Guidance for specification option: Insert requirement. Magnetic back painted glass.Magnetic whiteboard laminate.Perforated sound absorbent board.Guidance for specification option: Perforation specification by specifier; insert details as required. Priming sheet ready for ‘on site’ decoration by others.Guidance for specification option: Insert details as required. Slotted sound absorbent board.Guidance for specification option: Slot specification by specifier; insert details as required. Standard laminate.Stretch fabric system.Guidance for specification option: Thickness and fabric specification by specifier; insert details as required. Veneer.Guidance for specification option: Insert details of species type and cut. Whiteboard laminate.Manufacturer guidanceWhere panel type varies within the partition assembly, insert identifiers for panels after each selection. |
Panel Type | Full height hinged pass door. Guidance for specification option:
|
Track profile | Manufacturer guidance
|
Track layout | TL 1 ‘E’ system. Guidance for specification option:
TL 2 ‘Za’ system. Guidance for specification option:
TL 3 ‘Zb’ system. Guidance for specification option:
TL 4 ‘Z’ system. Guidance for specification option:
TL 5 ‘K’ system. Guidance for specification option:
Manufacturer guidancePlease note: If Type TL1 'E' track is specified then Rw 58dB (laboratory tested) sound reduction and Rw 60dB (laboratory tested) sound reduction is not suitable. |
Fire performance | Class 1 to BS 476. Guidance for specification option: Available with optional finish from standard range rated Class 1 Surface Spread of Flame, when tested to BS 476. Class 0 to Approved Document M. Guidance for specification option: In accordance with Building Regulation (E&W) Approved Document B. Manufacturer guidance
|
Partition assembly | Refer to manufacturer drawing (SL – 101, SL – 102 and SL – 103), for disposition of specified elements. |
Panel vertical edge type | Concealed. Exposed. |
Bunching | Bi–parting. Double stack. Single stack. |
Acoustic insulation | Rw 37 dB. Rw 41 dB. Rw 43 dB. Rw 44 dB. Rw 45 dB. Manufacturer guidancePlease note: If the Rw 58dB or Rw 60dB value is specified, then Type TL 1 'E' track single point suspension is not suitable. |
FireRating | Not fire rated. Guidance for specification option: Standard. 30 minute fire rated. 60 minute fire rated (no pass door). |
Ceiling angle trim | None. Exposed 20 mm from underside of ceiling. Guidance for specification option: Single point suspension only. Flush with underside of ceiling. Guidance for specification option: Two point suspension only. |
Track finish | White. Guidance for specification option: As standard, spray painted. RAL. Guidance for specification option: Spray painted, special order; insert requirement. Powder-coated aluminium, RAL. Guidance for specification option: Insert requirement. Satin anodized aluminium. Guidance for specification option: Standard. |
Country of material origin | Manufacturer guidanceGermany, Holland or Sweden |
Country of product manufacture | Manufacturer guidanceGermany, Holland or Sweden |
Recyclability | Metal parts can be separated and directed to material recycling. Theoretically, particle board can also be recycled by directing the panels to new production |
ISO 9001 Quality Management
ISO 9001 Abopart
ISO 9001 Quality Management
ISO 9001 Parthos
ISO 9001 Quality Management
ISO 9001 Winab
ISO 14001 Environmental Management Systems
London Wall Group Holdings 14001
EPD
Parthos EPD
Constructionline
Social Value Certificate Constructionline
Acclaim Accreditation
SSIP Acclaim