Verified by manufacturer 1 month ago
Structural In-Floorboard System
Underfloor heating systems.
Underfloor heating systems suitable for a variety of flooring projects.
Features and benefits:
Types:
Material | Stainless steel Plastic Expanded polystyrene (EPS) |
Shape | Circle |
Length | Bespoke |
Width | Bespoke Manufacturer guidance15–22 mm, dependent on area heating load/ zone circuit size. |
Height | Bespoke |
Warranty description | 50 year Guidance for specification option: Underfloor heating pipe. Five year Guidance for specification option: Underfloor manifold. Three year Guidance for specification option: Manifold pump station. Two year Guidance for specification option: Controls. |
Uniclass | |
CAWS | T90/475 Underfloor heating systems T90/475 Underfloor heating systems M42/340 Underfloor heating |
Heat source | Underfloor manifold.Guidance for specification option:
|
Pumps | Manifold pump station.Guidance for specification option:
|
Pipes | |
Distribution | Directly on floor joists. |
Underfloor | Insulation layer, tongue and joist panel with joists. |
Accessories | Heat diffusion plate.Touch-screen thermastat.PEX oxygen barrier pipe.Finished floorboards.Base™ PEX PIPEs. |
Controls | |
Controllers | Touch-screen thermostat.Guidance for specification option: Operated through wireless control, wifi or network. Mobile app.Guidance for specification option: Operated through wifi or network. Suitable for Apple and Android platforms. |
Sensors | Base™ Nickel plated manifold. |
Floor components | Finished floor.Engineered timber board.Guidance for specification option: 6 mm. Foil faced tape.PEX pipe.Tongue and groove panel.Joist.Insulation layer. |
System completion | Pre-grooved flooring panels.Guidance for specification option:
Pipework.Guidance for specification option:
|
System arrangement | Guidance for specification option: Base™ STRUCTURAL IN-BOARD SYSTEM. PEX pipe installed to pre-routed (2400 x 600 x 22mm) tongue & groove panel. Panel glued and screwed to 400 mm centre joists. 6mm engineered timber panel installed to tongue & groove panel. |
Spacing | Manufacturer guidancePipe spacing. |
Contains Red List materials | No |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 1 | |
- | 1 |