Zinc rainscreen cladding panel.

Jump to:
BOS
+44 (0)1992 921 300 Website

Application

  • Vertical cladding and soffits.
  • New buildings and renovations.
  • All types of buildings.

Description

Interlocking panels consist of a panel face, reveal joint and are fixed in position using hidden fasteners. The panels can be orientated horizontally or vertically and can be applied equally to soffits.

Panels are available in all finishes of 1 mm-thick VMZINC® with standard panel widths being 200, 250 and 300 mm. The maximum panel width is 333 mm and length 6 m; panels of less than 0.5 m are not recommended.

Joint widths can be either 10 or 20 mm. It should be noted that panel width = panel face + joint. The depth of the panel is 25 mm.

Structure:

  • The system is relatively lightweight as the panels weigh no more than 12 kg/m² and can be fixed back to both timber and metal sub frames.
  • Support rails are installed at 600 mm centres (maximum).
  • Aluminium rails are 2 mm-thick with both timber and aluminium rails requiring a supporting face of at least 40 mm.
  • All panels that are over 2 m in length must allow for thermal expansion and contraction by using stainless steel clips.
  • The fixed point being at the top of the panel for vertical installation and in the middle for horizontal installation.

Features and benefits:

  • Elegant linear panels.
  • Concealed fastening.
  • CWCT tested by UK fabricators.
  • Variable joint size.
  • Horizontal and vertical installation possible; vertical panels can be installed on a curved form on plan.

Typical system build-up:

  • VMZINC interlocking panels.
  • Metal framing creating a vented 38 mm airspace.
  • VMZINC Membrane.
  • Insulation.
  • Supporting structure (blockwork or metal framing or other appropriate supporting structure).

Life Cycle Analysis (LCA):

VMZINC undertakes Life Cycle Analysis (LCA) tests on its products and publishes Environmental Product Declarations (EPDs), such as BRE Environmental Profiles, available from the manufacturer's website www.vmzinc.co.uk and www.greenbooklive.com. These provide users with comprehensive, reliable and transparent information on relevant environmental characteristics. The information is also used by VMZINC as the basis for its eco-design approach.

General information

Color

Blue

Brown

Green

Grey

Red

Show more

Finish

Natural

Pre-treated

Material

Zinc

Shape

Rectangle

Length

200 mm

Guidance for specification option:

Panels.

250 mm

Guidance for specification option:

Panels.

300 mm

Guidance for specification option:

Panels.

333 mm

Guidance for specification option:

Panels, maximum.

Bespoke

Width

6000 mm

Guidance for specification option:

Maximum individual panel size.

Bespoke

Height

Bespoke

Warranty description

50 year

Guidance for specification option:

Up to 50 year material warranty available on a project basis.

Uniclass

Ss_25_20_70_25 Drained and back-ventilated rainscreen cladding systemsPrimary

CAWS

H92/120 Rainscreen cladding

Product range

Facades

Specification data - Drained and back-ventilated rainscreen cladding systems

Classification data

System performance

Guidance for specification option:

Insert requirements.

System manufacturer

VMZINC UK.

Thermal insulation

Guidance for specification option:

Insert requirements (supplied by others).

Breather membrane

-

Material

VMZINC® Membrane.

Fasteners

Manufacturer's standard.

Secondary support structure

Metal framing creating a vented 38 mm airspace.

Guidance for specification option:

Consult manufacturer for requirements.

Cladding panels

-

Material

Zinc, 200 x 6000 mm, solid.

Guidance for specification option:

Width x maximum length.

Zinc, 250 x 6000 mm, solid.

Guidance for specification option:

Width x maximum length.

Zinc, 300 x 6000 mm, solid.

Guidance for specification option:

Width x maximum length.

Zinc, 333 x 6000 mm, solid.

Guidance for specification option:

Maximum panel size.

Zinc, bespoke.

Guidance for specification option:

Insert requirements.

  • Length: maximum 6000 mm; panels <500 mm are not recommended.
  • Width: standard 200, 250 and 300 mm; maximum 333 mm.
  • Flat as standard; curved panels are available.

Manufacturer guidance

See also Colour and Perforations below for related options.

Panel joints

Interlocking, joint width 10 mm.
Interlocking, joint width 20 mm.

Reveals

Guidance for specification option:

Consult manufacturer's literature for details of window reveals.

Separate components also listed under System accessories below.

System accessories

VMZINC® continuous welted strip.

Guidance for specification option:

For parapet details.

Panel fixing clip.

Guidance for specification option:

For parapet details.

Roofing membrane.

Guidance for specification option:

For parapet details.

VMZINC® capping piece maximum 500 mm wide.

Guidance for specification option:

For parapet details.

VMZINC® folded clip; 1 mm thick; 250 mm wide.

Guidance for specification option:

For parapet details or window reveals.

Insect mesh.

Guidance for specification option:

For parapet details or window reveals.

VMZINC® welted panels with perforated grids.

Guidance for specification option:

For window reveals.

VMZINC® cover profile.

Guidance for specification option:

For window reveals.

Timber fixing pack.

Guidance for specification option:

For window reveals.

Intermittent timber fixing packs can be used to provide ventilation pathways.

VMZINC® flashing.

Guidance for specification option:

For window reveals.

VMZINC® soldered clip.

Guidance for specification option:

For window reveals.

VMZINC® sheet clip, 0.8 mm thick, 80 mm wide.

Guidance for specification option:

For window reveals.

Orientation

Horizontal.

Guidance for specification option:

All panels that are over 2 m in length must allow for thermal expansion and contraction by using stainless steel clips, the fixed point being at the middle of the panel.

Vertical.

Guidance for specification option:

All panels that are over 2 m in length must allow for thermal expansion and contraction by using stainless steel clips, the fixed point being at the top of the panel.

Vertical panels can be installed on a curved form on plan.

Colour

Natural VMZINC®, natural finish.

Guidance for specification option:

Natural VMZINC® has a shiny metallic appearance when new and develops a patina over time. In facade applications, it may take ten years for the matt grey patina to form.

Standard PIGMENTO® BLUE.

Guidance for specification option:

  • Pre-weathered finish.
  • Colouration of the zinc is achieved with a special pigment layer that enhances the qualities of the zinc without presenting a block colour.
  • Tested to EN 13523.
  • Provides an increased resilience. However in a severe non-rinsed marine environment (1 km from the sea), staining is still possible and therefore the material should not be used in this application.

Standard PIGMENTO® GREEN.

Guidance for specification option:

  • Pre-weathered finish.
  • Colouration of the zinc is achieved with a special pigment layer that enhances the qualities of the zinc without presenting a block colour.
  • Tested to EN 13523.
  • Provides an increased resilience. However in a severe non-rinsed marine environment (1 km from the sea), staining is still possible and therefore the material should not be used in this application.

Standard PIGMENTO® BROWN.

Guidance for specification option:

  • Pre-weathered finish.
  • Colouration of the zinc is achieved with a special pigment layer that enhances the qualities of the zinc without presenting a block colour.
  • Tested to EN 13523.
  • Provides an increased resilience. However in a severe non-rinsed marine environment (1 km from the sea), staining is still possible and therefore the material should not be used in this application.

Standard PIGMENTO® RED.

Guidance for specification option:

  • Pre-weathered finish.
  • Colouration of the zinc is achieved with a special pigment layer that enhances the qualities of the zinc without presenting a block colour.
  • Tested to EN 13523.
  • Provides an increased resilience. However in a severe non-rinsed marine environment (1 km from the sea), staining is still possible and therefore the material should not be used in this application.

Standard PIGMENTO® GREY.

Guidance for specification option:

  • Pre-weathered finish.
  • Colouration of the zinc is achieved with a special pigment layer that enhances the qualities of the zinc without presenting a block colour.
  • Tested to EN 13523.
  • Provides an increased resilience. However in a severe non-rinsed marine environment (1 km from the sea), staining is still possible and therefore the material should not be used in this application.

PIGMENTO® STORM GREY.

Guidance for specification option:

  • Pre-weathered finish.
  • Colouration of the zinc is achieved with a special pigment layer that enhances the qualities of the zinc without presenting a block colour.
  • Tested to EN 13523.
  • Provides an increased resilience. However in a severe non-rinsed marine environment (1 km from the sea), staining is still possible and therefore the material should not be used in this application.

PIGMENTO® CHARCOAL GREY.

Guidance for specification option:

  • Pre-weathered finish.
  • Colouration of the zinc is achieved with a special pigment layer that enhances the qualities of the zinc without presenting a block colour.
  • Tested to EN 13523.
  • Provides an increased resilience. However in a severe non-rinsed marine environment (1 km from the sea), staining is still possible and therefore the material should not be used in this application.

QUARTZ-ZINC®.

Guidance for specification option:

  • Pre-weathered finish.
  • Offers an appearance and texture that does not change over time.
  • When QUARTZ-ZINC® is scratched, it will self heal. The grey tones of QUARTZ-ZINC® blend well with existing construction materials. QUARTZ-ZINC® is produced through a phosphatation of mill finish Natural zinc.
  • The darkness of the pre-weathered zinc is measured electronically using a Y figure where 0 is black and 100 is white. Acceptable tolerance of QUARTZ-ZINC®, Y = 22 to 25.

ANTHRA-ZINC®.

Guidance for specification option:

  • Pre-weathered finish.
  • With its visible grain it matches the colour of slate and blends well in combination with photovoltaic panels.
  • Produced through a phosphatation of mill finish Natural zinc.
  • Acceptable tolerance of ANTHRA-ZINC®, Y = 5 to 7. Due to the dark colour of ANTHRA-ZINC® it should be carefully considered before using on non-rinsed surfaces such as protected facades and soffits.
  • For rinsed surfaces in coastal environments ANTHRA-ZINC® STRAT should be considered.

AZENGAR®.

Guidance for specification option:

Pre-weathered finish.

Engraved zinc giving a product with a matt, heterogeneous and light aspect.

Can be used in the same fashion as other VMZINC® products for both roofs and facades.

Perforations

Not required (solid).

Guidance for specification option:

Standard.

Required.

Guidance for specification option:

Insert requirements.

Perforations are available in standard sizes or as custom designs to create patterns, images and logos.

Weight

Panels: maximum 12 kg/m².

Standard

To BS EN 988, EN 15804, ISO 14001 and ISO 9001.

Reaction to fire

Fire classification according to EN 13501-1:2002:
A1 (Natural VMZINC, QUARTZ-ZINC, ANTHRA-ZINC and AZENGAR);
A2-s1,d0 (PIGMENTO and VMZINC PLUS).

Installation

The panels are installed in a sequential order from top to bottom for horizontal panels. The upper edge of each panel is engaged into the lower edge of the panel above. The panels are mechanically attached using screws and/ or the panel fixing clip that allows for thermal movement. The panels should be installed with the protective film in place.

VMZINC® PLUS must be used on all non-vertical flashings if open gap soft boards are not being used.

Sustainability data

Contains Red List materials

No

Country of material origin

France

Country of product manufacture

France

Material

Zinc

Recyclability

100%

Guidance for specification option:

Fully recyclable.

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

20 %

Guidance for specification option:

20% (approximately).

Expected Life

100 year

Product certifications

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
Revit

Revit 2016

2

IFC

IFC2X3

1

Product certifications

EPD

EPD

EPD for Natural Zinc

EPD

EPD

EPD for engraved AZENGAR

EPD

EPD

EPD for PIGMENTO

EPD

EPD

EPD for QUARTZ-ZINC and ANTHRA-ZINC

Literature

VMZINC Facades - Fully Supported Facades & Rainscreen Facades May 2024

VMZINC Facades - Fully Supported Facades & Rainscreen Facades May 2024

VMZINC Standing Seam Installation Guide - Information about the Use and Detailing of VMZINC May 2022

VMZINC Standing Seam Installation Guide - Information about the Use and Detailing of VMZINC May 2022

VMZINC General Technical Recommendations - Design Guidance for Architects & Contractors.

VMZINC General Technical Recommendations - Design Guidance for Architects & Contractors.

VMZINC EN15804 Natural Rolled Zinc

VMZINC EN15804 Natural Rolled Zinc

ISO 9001

ISO 9001

ISO 14001

ISO 14001

EN15804 Pre-Weathered QUARTZ PLUS & ANTHRA PLUS

EN15804 Pre-Weathered QUARTZ PLUS & ANTHRA PLUS

BRE Certification EN15804 Pre-Weathered Rolled QUARTZ & ANTHRA

BRE Certification EN15804 Pre-Weathered Rolled QUARTZ & ANTHRA

BRE Certification EN15804 Pre-Weathered PIGMENTO & STRAT

BRE Certification EN15804 Pre-Weathered PIGMENTO & STRAT

CPD materials

Zinc as a Facade Material

Zinc as a Facade Material

Case studies

Lampwick Quay, Manchester

Lampwick Quay, Manchester

Similar products from VMZINC UK

VMZINC Rainscreen Facades – Mozaik - Zinc Wall Panel Rainscreen Cladding

VMZINC Rainscreen Facades – Mozaik - Zinc Wall Panel Rainscreen Cladding

VMZINC Rainscreen Facades – Overlapping Panels - Zinc Shiplap Cladding Panel System

VMZINC Rainscreen Facades – Overlapping Panels - Zinc Shiplap Cladding Panel System

VMZINC Rainscreen Facades – Sine Wave

VMZINC Rainscreen Facades – Sine Wave