Sine wave profile corrugated zinc cladding.
A corrugated profile in zinc that can be fixed to a wooden or a metal framework using visible stainless steel fasteners. The standard profile for the panel is an 18/ 76 mm module which is available in both 0.8 and 1 mm thicknesses. The system can be used to clad walls both horizontally and vertically.
The system is fixed back to timber or metal (galvanized steel at least 1.5 mm thick or aluminium at least 2 mm thick) rails that are typically at centres of between 0.8 and 1.2 m (depending on loading). The rails must have a supporting face width of 40 mm and should allow a minimum vented space between the VMZ Sine Wave panel and the insulation/sheathing of 38 mm.
For panels over 3 m in length slotted or over-size holes must be pre-drilled to allow the thermal expansion and contraction of the panels to take place.
Features and benefits:
Typical system build-up:
Life Cycle Analysis (LCA):
VMZINC undertakes Life Cycle Analysis (LCA) tests on its products and publishes Environmental Product Declarations (EPDs), such as BRE Environmental Profiles, available from manufacturer's website www.vmzinc.co.uk and www.greenbooklive.com. These provide users with comprehensive, reliable and transparent information on relevant environmental characteristics. The information is also used by VMZINC as the basis for its eco-design approach.
Color | Blue Brown Green Grey Red |
Finish | Natural Pre-treated |
Material | Zinc |
Shape | Manufacturer guidanceSine wave. |
Length | 836 mm Guidance for specification option: Maximum individual panel width. Bespoke |
Width | 6000 mm Guidance for specification option: Maximum individual panel length. Bespoke |
Height | 18 mm |
Warranty description | 50 year Guidance for specification option: Up to 50 year material warranty available on a project basis. |
Uniclass | |
CAWS | H92/120 Rainscreen cladding |
Product range |
Classification data | |
System performance | Guidance for specification option: Insert requirements. |
System manufacturer | VMZINC UK. |
Thermal insulation | Guidance for specification option: Insert requirements (supplied by others). |
Breather membrane | |
Material | VMZINC Membrane. |
Fasteners | Manufacturer's standard. |
Secondary support structure | Metal framing creating a 38 mm airspace. Guidance for specification option: Insert details. The system is fixed back to timber or metal (galvanized steel at least 1.5 mm thick or aluminium at least 2 mm thick) rails that are typically at centres of between 0.8 m and 1.2 m depending on loading. The rails must have a supporting face width of 40 mm and should allow a minimum vented space between the VMZINC® sine wave panel and the insulation/sheathing of 38 mm. |
Cladding panels | |
Material | Zinc, 0.8 mm thick. Zinc, 1 mm thick. |
Panel joints | Panels are fixed in place with stainless steel screws on every other wave. Horizontal joints overlap; vertical joints sit side by side with a flashing behind making them weathertight. |
Reveals | Guidance for specification option: Insert requirements e.g. expansion joint detail or window details. Consult manufacturer's literature for required accessories. Manufacturer guidanceSee also System accessories for related components. |
System accessories | VMZINC® flashing. Guidance for specification option: For expansion joint details or window details. Panel fixing. Guidance for specification option: For expansion joint details. Insect mesh. Guidance for specification option: For window details. VMZINC® continuous welted strip. Guidance for specification option: For window details. VMZINC® folded clip. Guidance for specification option: For window details. 1 mm thick, width 250 mm. Two per metre. VMZINC® PLUS sheet clip. Guidance for specification option: For window details. 0.8 mm thick, width 80 mm. Two per metre. |
Colour | Natural VMZINC®, natural finish. Guidance for specification option: Natural VMZINC® has a shiny metallic appearance when new and develops a patina over time. In facade applications, it may take ten years for the matt grey patina to form. Standard PIGMENTO® BLUE. Guidance for specification option:
Standard PIGMENTO® GREEN. Guidance for specification option:
Standard PIGMENTO® BROWN. Guidance for specification option:
Standard PIGMENTO® RED. Guidance for specification option:
Standard PIGMENTO® GREY. Guidance for specification option:
PIGMENTO® STORM GREY. Guidance for specification option:
PIGMENTO® CHARCOAL GREY. Guidance for specification option:
QUARTZ-ZINC®. Guidance for specification option:
ANTHRA-ZINC®. Guidance for specification option:
AZENGAR®. Guidance for specification option:
|
Panel width | Guidance for specification option: Insert requirements, maximum 836 mm. |
Panel length | Guidance for specification option: Insert requirements, maximum 6 m. |
Perforations | Not required. Guidance for specification option: Standard. Required. Guidance for specification option: Insert requirements. Perforations are available in standard sizes or as custom designs to create patterns, images and logos. |
Profile | Sine wave, 18/ 76 mm module. |
Reaction to fire | Fire classification according to EN 13501-1:2002: A1 (Natural Zinc, QUARTZ ZINC, ANTHRA-ZINC and AZENGAR); A2-s1,d0 (PIGMENTO and VMZINC PLUS). |
Standard | To BS EN 988, EN 15804, ISO 14001 and ISO 9001. |
Installation | The panels are installed in a sequential order from bottom up. Panels are fixed in place with stainless steel screws on every other wave. For panels over 3 m in length slotted or over-size holes must be pre-drilled to allow the thermal expansion and contraction of the panels to take place. The panels should be installed with the protective film in place. VMZINC® PLUS must be used on all non-vertical flashings if open gap soft boards are not being used. |
Contains Red List materials | No |
Country of material origin | France |
Country of product manufacture | France |
Material | Zinc |
Recyclability | 100% Guidance for specification option: Fully recyclable. |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 20 % Guidance for specification option: 20% (approximately). |
Expected Life | 100 year |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
![]() | Revit 2016 | 2 |
![]() | IFC2X3 | 1 |
VMZINC Facades - Fully Supported Facades & Rainscreen Facades May 2024
VMZINC EN15804 Natural Rolled Zinc
BRE Certification EN15804 Pre-Weathered PIGMENTO & STRAT
BRE Certification EN15804 Pre-Weathered Rolled QUARTZ & ANTHRA
EN15804 Pre-Weathered QUARTZ PLUS & ANTHRA PLUS
VMZINC General Technical Recommendations - Design Guidance for Architects & Contractors.
ISO 9001
ISO 14001