Sine wave profile corrugated zinc cladding.

Jump to:
BOS
+44 (0)1992 921 300 Website

Application

  • New construction or refurbishment projects.
  • Flat facade.
  • All types of buildings, in particular office and public buildings and collective housing.


Description

A corrugated profile in zinc that can be fixed to a wooden or a metal framework using visible stainless steel fasteners. The standard profile for the panel is an 18/ 76 mm module which is available in both 0.8 and 1 mm thicknesses. The system can be used to clad walls both horizontally and vertically.

The system is fixed back to timber or metal (galvanized steel at least 1.5 mm thick or aluminium at least 2 mm thick) rails that are typically at centres of between 0.8 and 1.2 m (depending on loading). The rails must have a supporting face width of 40 mm and should allow a minimum vented space between the VMZ Sine Wave panel and the insulation/sheathing of 38 mm.

 

For panels over 3 m in length slotted or over-size holes must be pre-drilled to allow the thermal expansion and contraction of the panels to take place.

Features and benefits:

  • Offers a more industrial aesthetic.
  • Very simple installation.
  • Cost effective.
  • Available in all finishes.

Typical system build-up:

  • VMZINC Sine Wave panels.
  • Stainless steel screws.
  • Metal framing creating a vented 38 mm airspace.
  • VMZINC Membrane.
  • Insulation.
  • Supporting structure (blockwork or metal framing or other appropriate supporting structure).

Life Cycle Analysis (LCA):

VMZINC undertakes Life Cycle Analysis (LCA) tests on its products and publishes Environmental Product Declarations (EPDs), such as BRE Environmental Profiles, available from manufacturer's website www.vmzinc.co.uk and www.greenbooklive.com. These provide users with comprehensive, reliable and transparent information on relevant environmental characteristics. The information is also used by VMZINC as the basis for its eco-design approach.

General information

Color

Blue

Brown

Green

Grey

Red

Show more

Finish

Natural

Pre-treated

Material

Zinc

Shape

-

Manufacturer guidance

Sine wave.


Length

836 mm

Guidance for specification option:

Maximum individual panel width.

Bespoke

Width

6000 mm

Guidance for specification option:

Maximum individual panel length.

Bespoke

Height

18 mm

Warranty description

50 year

Guidance for specification option:

Up to 50 year material warranty available on a project basis.

Uniclass

Ss_25_20_70_25 Drained and back-ventilated rainscreen cladding systemsPrimary

CAWS

H92/120 Rainscreen cladding

Product range

Facades

Specification data - Drained and back-ventilated rainscreen cladding systems

Classification data

System performance

Guidance for specification option:

Insert requirements.

System manufacturer

VMZINC UK.

Thermal insulation

Guidance for specification option:

Insert requirements (supplied by others).

Breather membrane

-

Material

VMZINC Membrane.

Fasteners

Manufacturer's standard.

Secondary support structure

Metal framing creating a 38 mm airspace.

Guidance for specification option:

Insert details.

The system is fixed back to timber or metal (galvanized steel at least 1.5 mm thick or aluminium at least 2 mm thick) rails that are typically at centres of between 0.8 m and 1.2 m depending on loading.

The rails must have a supporting face width of 40 mm and should allow a minimum vented space between the VMZINC® sine wave panel and the insulation/sheathing of 38 mm.

Cladding panels

-

Material

Zinc, 0.8 mm thick.
Zinc, 1 mm thick.

Panel joints

Panels are fixed in place with stainless steel screws on every other wave.
Horizontal joints overlap; vertical joints sit side by side with a flashing behind making them weathertight.

Reveals

Guidance for specification option:

Insert requirements e.g. expansion joint detail or window details.

Consult manufacturer's literature for required accessories.

Manufacturer guidance

See also System accessories for related components.

System accessories

VMZINC® flashing.

Guidance for specification option:

For expansion joint details or window details.

Panel fixing.

Guidance for specification option:

For expansion joint details.

Insect mesh.

Guidance for specification option:

For window details.

VMZINC® continuous welted strip.

Guidance for specification option:

For window details.

VMZINC® folded clip.

Guidance for specification option:

For window details.

1 mm thick, width 250 mm. Two per metre.

VMZINC® PLUS sheet clip.

Guidance for specification option:

For window details.

0.8 mm thick, width 80 mm. Two per metre.

Colour

Natural VMZINC®, natural finish.

Guidance for specification option:

Natural VMZINC® has a shiny metallic appearance when new and develops a patina over time. In facade applications, it may take ten years for the matt grey patina to form.

Standard PIGMENTO® BLUE.

Guidance for specification option:

  • Pre-weathered finish.
  • Colouration of the zinc is achieved with a special pigment layer that enhances the qualities of the zinc without presenting a block colour.
  • Tested to EN 13523.
  • Provides an increased resilience. However in a severe non-rinsed marine environment (1 km from the sea), staining is still possible and therefore the material should not be used in this application.

Standard PIGMENTO® GREEN.

Guidance for specification option:

  • Pre-weathered finish.
  • Colouration of the zinc is achieved with a special pigment layer that enhances the qualities of the zinc without presenting a block colour.
  • Tested to EN 13523.
  • Provides an increased resilience. However in a severe non-rinsed marine environment (1 km from the sea), staining is still possible and therefore the material should not be used in this application.

Standard PIGMENTO® BROWN.

Guidance for specification option:

  • Pre-weathered finish.
  • Colouration of the zinc is achieved with a special pigment layer that enhances the qualities of the zinc without presenting a block colour.
  • Tested to EN 13523.
  • Provides an increased resilience. However in a severe non-rinsed marine environment (1 km from the sea), staining is still possible and therefore the material should not be used in this application.

Standard PIGMENTO® RED.

Guidance for specification option:

  • Pre-weathered finish.
  • Colouration of the zinc is achieved with a special pigment layer that enhances the qualities of the zinc without presenting a block colour.
  • Tested to EN 13523.
  • Provides an increased resilience. However in a severe non-rinsed marine environment (1 km from the sea), staining is still possible and therefore the material should not be used in this application.

Standard PIGMENTO® GREY.

Guidance for specification option:

  • Pre-weathered finish.
  • Colouration of the zinc is achieved with a special pigment layer that enhances the qualities of the zinc without presenting a block colour.
  • Tested to EN 13523.
  • Provides an increased resilience. However in a severe non-rinsed marine environment (1 km from the sea), staining is still possible and therefore the material should not be used in this application.

PIGMENTO® STORM GREY.

Guidance for specification option:

  • Pre-weathered finish.
  • Colouration of the zinc is achieved with a special pigment layer that enhances the qualities of the zinc without presenting a block colour.
  • Tested to EN 13523.
  • Provides an increased resilience. However in a severe non-rinsed marine environment (1 km from the sea), staining is still possible and therefore the material should not be used in this application.

PIGMENTO® CHARCOAL GREY.

Guidance for specification option:

  • Pre-weathered finish.
  • Colouration of the zinc is achieved with a special pigment layer that enhances the qualities of the zinc without presenting a block colour.
  • Tested to EN 13523.
  • Provides an increased resilience. However in a severe non-rinsed marine environment (1 km from the sea), staining is still possible and therefore the material should not be used in this application.

QUARTZ-ZINC®.

Guidance for specification option:

  • Pre-weathered finish.
  • Offers an appearance and texture that does not change over time.
  • When QUARTZ-ZINC® is scratched, it will self heal. The grey tones of QUARTZ-ZINC® blend well with existing construction materials. QUARTZ-ZINC® is produced through a phosphatation of mill finish Natural zinc.
  • The darkness of the pre-weathered zinc is measured electronically using a Y figure where 0 is black and 100 is white. Acceptable tolerance of QUARTZ-ZINC®, Y = 22 to 25.

ANTHRA-ZINC®.

Guidance for specification option:

  • Pre-weathered finish.
  • With its visible grain it matches the colour of slate and blends well in combination with photovoltaic panels.
  • Produced through a phosphatation of mill finish Natural zinc.
  • Acceptable tolerance of ANTHRA-ZINC®, Y = 5 to 7. Due to the dark colour of ANTHRA-ZINC® it should be carefully considered before using on non-rinsed surfaces such as protected facades and soffits.
  • For rinsed surfaces in coastal environments ANTHRA-ZINC® STRAT should be considered.

AZENGAR®.

Guidance for specification option:

  • Pre-weathered finish.
  • Engraved zinc giving a product with a matt, heterogeneous and light aspect.
  • Can be used in the same fashion as other VMZINC® products for both roofs and facades.

Panel width

Guidance for specification option:

Insert requirements, maximum 836 mm.

Panel length

Guidance for specification option:

Insert requirements, maximum 6 m.

Perforations

Not required.

Guidance for specification option:

Standard.

Required.

Guidance for specification option:

Insert requirements.

Perforations are available in standard sizes or as custom designs to create patterns, images and logos.

Profile

Sine wave, 18/ 76 mm module.

Reaction to fire

Fire classification according to EN 13501-1:2002:
A1 (Natural Zinc, QUARTZ ZINC, ANTHRA-ZINC and AZENGAR);
A2-s1,d0 (PIGMENTO and VMZINC PLUS).

Standard

To BS EN 988, EN 15804, ISO 14001 and ISO 9001.

Installation

The panels are installed in a sequential order from bottom up. Panels are fixed in place with stainless steel screws on every other wave. For panels over 3 m in length slotted or over-size holes must be pre-drilled to allow the thermal expansion and contraction of the panels to take place.

The panels should be installed with the protective film in place.

VMZINC® PLUS must be used on all non-vertical flashings if open gap soft boards are not being used.

Sustainability data

Contains Red List materials

No

Country of material origin

France

Country of product manufacture

France

Material

Zinc

Recyclability

100%

Guidance for specification option:

Fully recyclable.

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

20 %

Guidance for specification option:

20% (approximately).

Expected Life

100 year

Product certifications

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
Revit

Revit 2016

2

IFC

IFC2X3

1

Product certifications

EPD

EPD

EPD for Natural Zinc

EPD

EPD

EPD for engraved AZENGAR

EPD

EPD

EPD for PIGMENTO

EPD

EPD

EPD for QUARTZ-ZINC and ANTHRA-ZINC

Literature

VMZINC Facades - Fully Supported Facades & Rainscreen Facades May 2024

VMZINC Facades - Fully Supported Facades & Rainscreen Facades May 2024

VMZINC EN15804 Natural Rolled Zinc

VMZINC EN15804 Natural Rolled Zinc

BRE Certification EN15804 Pre-Weathered PIGMENTO & STRAT

BRE Certification EN15804 Pre-Weathered PIGMENTO & STRAT

BRE Certification EN15804 Pre-Weathered Rolled QUARTZ & ANTHRA

BRE Certification EN15804 Pre-Weathered Rolled QUARTZ & ANTHRA

EN15804 Pre-Weathered QUARTZ PLUS & ANTHRA PLUS

EN15804 Pre-Weathered QUARTZ PLUS & ANTHRA PLUS

VMZINC General Technical Recommendations - Design Guidance for Architects & Contractors.

VMZINC General Technical Recommendations - Design Guidance for Architects & Contractors.

ISO 9001

ISO 9001

ISO 14001

ISO 14001

Case studies

Whisstocks Boatyard, Woodbridge, Suffolk

Whisstocks Boatyard, Woodbridge, Suffolk

Similar products from VMZINC UK

VMZINC Rainscreen Facades – Interlocking Panels

VMZINC Rainscreen Facades – Interlocking Panels

VMZINC Rainscreen Facades – Mozaik - Zinc Wall Panel Rainscreen Cladding

VMZINC Rainscreen Facades – Mozaik - Zinc Wall Panel Rainscreen Cladding

VMZINC Rainscreen Facades – Overlapping Panels - Zinc Shiplap Cladding Panel System

VMZINC Rainscreen Facades – Overlapping Panels - Zinc Shiplap Cladding Panel System