Verified by manufacturer 1 month ago
A cementitious flexible waterproofing coating.
Suitable for waterproofing structures that are subjected to negative hydrostatic pressure and typically constructed of reinforced concrete, masonry block and brickwork.
Typical waterproofing applications include:
VOLSEAL 250 is not designed for use as waterproofing membrane for plaza/ podium decks or green roofs.
A highly elastic waterproof coating consisting of aggregates, cement-based binders and acrylic polymers. Once cured, it forms an an impervious and elastomeric barrier with crack-bridging properties of up to 0.8 mm in width.
Features and benefits:
Color | Grey White |
Material | Acrylic Guidance for specification option: Polymers. Stone Guidance for specification option: Aggregates. Cement Guidance for specification option: Cement-based binders. |
Shape | Formless Guidance for specification option: Two parts, powder and liquid. |
Uniclass | |
CAWS | J30/10 Cold-applied damp-proofing J30/110 Cold-applied tanking J30/130 Cold-applied damp-proofing |
Colour | Grey powder, white latex. |
Application temperature | 5-40°C. |
Application thickness | 4 mm (maximum). Guidance for specification option: Consult manufacturer and insert requirement. |
Coverage per coat | First coat: 1.7-2.0 kg/m², Second coat: 1.5-2.0 kg/m². Guidance for specification option:
|
Pot life - 20 °C | 20 minutes. |
Working temperature | –5°C to +50°C. |
Specific weight | >1.7 kg/L. |
Mix | Part A/ Part B mixing ratio – 2.5:1. |
Bond strength | ≥0.8 MPa to UNI EN 1542. Guidance for specification option: Data obtained in laboratory conditions at +20°C and 60% RH. |
Ageing | Resistance to accelerated ageing: No swelling to UNI EN 1062-11. Guidance for specification option: Data obtained in laboratory conditions at +20°C and 60% RH. |
Capillary absorption | ≥0.05 kg/m² x h^–0.5 to UNI EN 1062-3. Guidance for specification option: Data obtained in laboratory conditions at +20°C and 60% RH. |
Water vapour permeability | S≤10 m to UNI EN 7783-2. Guidance for specification option: Equivalent thickness: S. |
Crack bridging | >0.75 mm to UNI EN 14891 and Method A.8.2. Guidance for specification option: Data obtained in laboratory conditions at +20°C and 60% RH. |
Adhesion | >0.7 N/mm² (initial) to UNI EN 14891, Method A.6.2 and A.6.3. Guidance for specification option: Adhesion to wall initial value after immersion in water. Manufacturer guidanceData obtained in laboratory conditions at +20°C and 60% RH. |
Seal | Hydraulic seal on 1 mm cracks: 100 kPa (no water infiltration after 7 days) to UNI EN 14891 Method A.8.2. Guidance for specification option: Data obtained in laboratory conditions at +20°C and 60% RH. |
Liquid waterproofing | 100 kPa (no water infiltration after 7 days) to UNI EN 14891 Method A.7. Guidance for specification option: Data obtained in laboratory conditions at +20°C and 60% RH. |
WaterImpermeability | Impermeability in negative pressure: 150 kPa, 50 kPa with a 0.4 mm cracked surface (pass or non-pass internal test method). Guidance for specification option: Data obtained in laboratory conditions at +20°C and 60% RH. |
TensileStrength | 1.14 MPa to DIN 53455. Guidance for specification option: Data obtained in laboratory conditions at +20°C and 60% RH. |
Elongation at break | 47% to DIN 53455. Guidance for specification option: Data obtained in laboratory conditions at +20°C and 60% RH. |