NBS Source
I'm a manufacturer

Compare variants

Legrand Floor Trunking Systems
Legrand Floor Trunking Systems
Legrand Floor Trunking Systems

Verified 3 days ago

Legrand Electric Ltd

Verified 3 days ago

Legrand Electric Ltd

Verified 3 days ago

Legrand Electric Ltd
Summary
A range of flush and in-screed cable management floor systems.
-
-
Application

Suitable for commercial and industrial applications.

-
-
Description

A range of flush and in-screed cable management floor systems.

The range includes: Flush Floor Trunking, Shallow Flush Floor Trunking, Underfloor Duct, Commercial Floor Trunking Recessed & Flush, Chequer Plate Floor Trunking and associated floor boxes and accessories.

Flush Floor Trunking is suitable for distributing power, data and communication in any commercial environment. It can be used if service outlets are required. Cables can be accessed after installation has been completed. Floor boxes can be positioned at any point along the trunking and removed and repositioned at a later date.

Shallow Flush Floor Trunking is designed to distribute power, data and communication where the amount of screed that can be removed is limited. It can be used if service outlets are required. Cables can be accessed after installation has been completed.

Underfloor Duct is installed under the screed, providing a strong yet cost-effective solution. The position of service outlets and junction boxes is fixed before installation. Service outlets and junction boxes are height-adjustable to fit flush with the screed.

Features and benefits:

  • All outlet systems are designed to accept a wide range of mix-and-match lids and trims.
  • Bespoke metal trims are available in any RAL reference to suit a building’s design scheme.
-
-
Color
Grey, Other
-
-
Finish
Galvanized, Powder-coated
-
-
Material
Steel
-
-
Shape
Rectangle
-
-
Length
2000 mm
-
-
Width
370 mm, 150 mm, 225 mm, 300 mm, 100 mm
-
-
Height
65 mm, 25 mm, 38 mm, 50 mm, 75 mm, 100 mm
-
-
Warranty description
Two year
-
-
SKU Code
FFO, AFS, AFU, FF, FRL, FTP
-
-

Specification

Classification data
Standards
To BS EN 61534 and BS EN 50085.
-
-
Resistance to impact
2 J.
-
-
Temperature properties
-
-
-
Storage and transport temperature (minimum)
-25°C.
-
-
Installation and application temperature (minimum)
-15°C.
-
-
Application temperature (maximum)
+60°C.
-
-
Resistance to flame propagation
Non-flame-propagating.
-
-
Electrical properties
With electrical continuity characteristics. Without electrical insulating characteristics.
-
-
Sizes
100 x 50 mm., 150 x 75 mm., 300 x 100 mm.
-
-
Compartments
Three., Four.
-
-
Accessories and fittings
-
-
-
Generally
Factory-made by the cable trunking or ducting manufacturer and of the same material type and finish as the cable trunking or ducting.
-
-
Types
90° riser bend., End stop., Junction box.
-
-

Additional properties

Material/ Finish
Body: Pre-galvanized sheet steel to BS EN 10346.
Lid: Mild steel, powder-coated grey 18B25.
-
-

Sustainability data

Material
Steel
-
-