NBS Source
I'm a manufacturer

Compare variants

Low Thermal Conductivity Wall Ties - Helical Cavity Tie
Low Thermal Conductivity Wall Ties - Helical Cavity Tie
Low Thermal Conductivity Wall Ties - Helical Cavity Tie

Verified 1 month ago

Vista Engineering Ltd

NEUTRAS 4

Verified 1 month ago

Vista Engineering Ltd

NEUTRAS 2

Verified 1 month ago

Vista Engineering Ltd

NEUTRAS 1

Summary
For securing two leaves of a cavity wall to each other, allowing them to act as one structurally.
For securing two leaves of a cavity wall to each other, allowing them to act as one structurally.
For securing two leaves of a cavity wall to each other, allowing them to act as one structurally.
Application
  • Light-duty wall ties (type 4) are suitable for use in domestic dwellings. Suitable for buildings with a maximum height of 10 m and cavity widths of 50–150 mm.
  • General-purpose wall ties (type 2) are suitable for use in small commercial buildings and domestic dwellings. Suitable for buildings with a maximum height of 15 m and cavity widths of 50–125 and 125–150 mm.
  • Heavy-duty wall ties (type 1) are suitable for most buildings in the UK of any height, with cavities up to 150 mm.
  • Light-duty wall ties (type 4) are suitable for use in domestic dwellings. Suitable for buildings with a maximum height of 10 m and cavity widths of 50–150 mm.
  • General-purpose wall ties (type 2) are suitable for use in small commercial buildings and domestic dwellings. Suitable for buildings with a maximum height of 15 m and cavity widths of 50–125 and 125–150 mm.
  • Heavy-duty wall ties (type 1) are suitable for most buildings in the UK of any height, with cavities up to 150 mm.
  • Light-duty wall ties (type 4) are suitable for use in domestic dwellings. Suitable for buildings with a maximum height of 10 m and cavity widths of 50–150 mm.
  • General-purpose wall ties (type 2) are suitable for use in small commercial buildings and domestic dwellings. Suitable for buildings with a maximum height of 15 m and cavity widths of 50–125 and 125–150 mm.
  • Heavy-duty wall ties (type 1) are suitable for most buildings in the UK of any height, with cavities up to 150 mm.
Description

For securing two leaves of a cavity wall to each other, allowing them to act as one structurally.


Features and benefits:

  • Will adequately resist thermal transmittance.
  • Constant drip feature to prevent moisture travelling across the cavity.
  • Available with a dedicated clip to secure insulation (usually in sheet form) within the cavity.
  • Tested as Type B (sound).
  • Tested Types 4, 2, & 1 to BS EN 845-1.
  • BBA certified 17/5462.

For securing two leaves of a cavity wall to each other, allowing them to act as one structurally.


Features and benefits:

  • Will adequately resist thermal transmittance.
  • Constant drip feature to prevent moisture travelling across the cavity.
  • Available with a dedicated clip to secure insulation (usually in sheet form) within the cavity.
  • Tested as Type B (sound).
  • Tested Types 4, 2, & 1 to BS EN 845-1.
  • BBA certified 17/5462.

For securing two leaves of a cavity wall to each other, allowing them to act as one structurally.


Features and benefits:

  • Will adequately resist thermal transmittance.
  • Constant drip feature to prevent moisture travelling across the cavity.
  • Available with a dedicated clip to secure insulation (usually in sheet form) within the cavity.
  • Tested as Type B (sound).
  • Tested Types 4, 2, & 1 to BS EN 845-1.
  • BBA certified 17/5462.
Product certifications
Color
Black
Black
Black
Material
Fibre
Fibre
Fibre
Length
200 mm, 225 mm, 250 mm, 275 mm, 300 mm, 325 mm, 350 mm, 375 mm, 400 mm, 425 mm
200 mm, 225 mm, 250 mm, 275 mm, 300 mm, 325 mm, 350 mm, 375 mm, 400 mm, 425 mm
200 mm, 225 mm, 250 mm, 275 mm, 300 mm, 325 mm, 350 mm, 375 mm, 400 mm, 425 mm
SKU Code
NEUTRAS-4, NEUTRAS-2, NEUTRAS-1
NEUTRAS-4, NEUTRAS-2, NEUTRAS-1
NEUTRAS-4, NEUTRAS-2, NEUTRAS-1

Specification

Classification data
Standard
To BS EN 845-1.
To BS EN 845-1.
To BS EN 845-1.
Tie type
PD 6697 Type 4 (Masonry – light duty).
PD 6697 Type 2 (Masonry – general purpose).
PD 6697 Type 1 (Masonry – heavy duty).
Material
Basalt fibre composite.
Basalt fibre composite.
Basalt fibre composite.
Length
200 mm., 225 mm., 250 mm., 275 mm., 300 mm.
200 mm., 225 mm., 250 mm., 275 mm., 300 mm., 325 mm., 350 mm., 375 mm., 400 mm., 425 mm.
200 mm., 225 mm., 250 mm., 275 mm.
End types
Manufacturer's standard.
Manufacturer's standard.
Manufacturer's standard.
Design embedment length (minimum)
Manufacturer's standard.
Manufacturer's standard.
Manufacturer's standard.
Movement
Manufacturer's standard.
Manufacturer's standard.
Manufacturer's standard.
Additional requirements
-
-
-
Mortar joint thickness (minimum)
-
-
-
Resistance to water crossing cavity
Resistant (constant drip feature).
Resistant (constant drip feature).
Resistant (constant drip feature).
Slope tolerance
Manufacturer's standard.
Manufacturer's standard.
Manufacturer's standard.
Compressive load capacity
Manufacturer's standard.
Manufacturer's standard.
Manufacturer's standard.
Tensile load capacity
Manufacturer's standard.
Manufacturer's standard.
Manufacturer's standard.
Dynamic stiffness
Type B.
Type B.
Type B.
Tie-mounted insulation retaining clips
ECO-clips., Not required.
ECO-clips., Not required.
ECO-clips., Not required.

Additional properties

Third party accreditation
BBA 17/5462.
BBA 17/5462.
BBA 17/5462.